Permit Information
Permit NumberBLD17-02496
StatusFinaled
Name FRED MEYER
Site Address 10751 W OVERLAND RD
Project NameFred Meyer - Clicklist Storage
Customer Number 
ePlanReviewYes
Description
(FRED MYER – ONLINE CHECKLIST STORAGE) Permit is to remodel an existing 1,436 sq. ft. area within an existing Fred Myer retail store. Approval is contingent upon adhering to the approved plans on file. Scope of work includes: removal of select interior nonbearing wall, removal of select door/door frames, removal of select suspended acoustic ceiling, removal of select plumbing fixtures, construction of select interior nonbearing wall to create checklist storage area and a stock area, a new 104 sq. ft. cooler, select new door/door frames, a new rooftop RTU, select new suspended acoustic ceiling, relocated and new lighting fixtures, electrical work, mechanical work, plumbing work and finishes in compliance with chapter 8 of the 2012 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. JG
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  1/3/2018 DONE
Third Notice 11/19/201712/12/2017 DONE
Mailed 12-13-17
Second Notice 10/22/201711/14/2017 DONE
Mailed 11-15-17
First Notice10/11/201710/11/201710/12/2017 DONE
DetailsMike Jordan
Mailed 10-13-17
BLD-Final10/10/201710/11/201710/11/2017PPASS
DetailsMike Jordan
Davin Phone #: ###-####
DOC - Permit Finaled10/11/201710/11/201710/11/2017PPASS
DetailsMike Jordan
FIRE-Final Inspection10/10/201710/11/201710/11/2017PPASS
DetailsTroy Cobbley
Life safety passed
FIRE-Final Inspection10/6/201710/6/201710/6/2017PFAIL
DetailsTroy Cobbley
I met Ben with ESI on site and discussed the previously noted correction issues
BLD-Conference10/6/201710/6/201710/6/2017PNR
DetailsMike Jordan
Matt Phone #: ###-####
FIRE-Conference10/5/201710/6/201710/6/2017ADONE
DetailsTroy Cobbley
Matt and I went through the life safety. Will need to test the emergency lights and exit signs. Also the existing fire alarm system will need to be extended/modified in the remodeled space as per discussion.

Matt Phone #: ###-####
BLD-Final10/5/201710/6/201710/6/2017PCANC
DetailsMike Jordan
Matt Phone #: ###-#### Per Matt wanted a conference instead
BLD-Ceiling Grid Inspection9/27/20179/27/20179/27/2017PCANC
DetailsBrandon Shaw
OK to cover
BLD-Final9/27/20179/27/20179/27/2017PCANC
DetailsBrandon Shaw
Matt Phone #: ###-####
BLD-Ceiling Grid Inspection9/20/20179/21/20179/21/2017ANR
DetailsBrandon Shaw
Need other trades ceiling
BLD-Framing/Rough-in9/7/20179/8/20179/8/2017APASS
DetailsMike Jordan
Matt Phone #: ###-####. Interior steel stud framed walls only ok.
Issue PAID IN FULL permit  8/25/2017 DONE
Inspection Record Card- Bld  8/25/2017 DONE
Route to Impact Fee Review8/22/20178/25/20178/23/2017 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Plan assigned to (JG)7/28/20177/28/20178/23/2017 PASS
DetailsJavier Guzman
1st rev comp, 8/10 L2 Fred Meyer Clicklist ePlan, pend DR
Routing - PLAN CHECK8/23/2017 8/23/2017 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  8/23/2017 DONE
Permit Ready to Issue  8/23/2017 DONE
DetailsChristina Prado
Need:
MET GC Form
MET Revised Cert of Value
1st review completed  8/22/2017 FAIL
DetailsJavier Guzman
Routing - Design Review8/22/2017 8/22/2017 PASS
DetailsKatelyn Menuge
Routing - PLAN CHECK8/22/2017 8/22/2017 FAIL
DetailsJavier Guzman
Routing - FIRE8/9/20178/9/20178/21/2017 PASS
DetailsScott Arellano
Attached comments to plans.
Routing Off Site - C.D.H7/28/2017 8/9/2017 PASS
DetailsJavier Guzman
signed off in ePlan by Central District Health Department
Joe Antonucci
Routing - PLAN CHECK7/28/2017 8/9/2017 PASS
DetailsJavier Guzman
Routing - Design Review7/28/2017 7/31/2017 FAIL
DetailsKatelyn Menuge
Accurate overall site plan and parking count needed.
Routing - Addressing7/28/2017 7/31/2017 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS7/28/2017 7/28/2017 PASS
DetailsBeverly Mountain
Routing - MECHANICAL7/28/2017 7/28/2017 PASS
DetailsTroy James
Routing - PLUMBING7/28/2017 7/28/2017 PASS
DetailsDaryl Spivey
Intake Approval  7/28/2017 PASS
DetailsJavier Guzman
Plan Reviewer's activity  7/27/2017 DONE
Spoke with applicant regarding CDHD approval. He said Joe at CDHD requested plans be routed to him in ePlanReview and he would approve them through ePlanReview.
Intake Approval  7/25/2017 FAIL
DetailsJulie Romig
Need:
1. CDHD approved plans - indicated on checklist but not provided.
Application received  7/19/2017 DONE
Application submitted via PDS Online on Jul 19 2017 3:04PM