Third Notice | | 1/17/2018 | 1/24/2018 | | DONE |
|
|
|
This permit finaled on the web by troy skidmore
|
Third Notice | | 12/17/2017 | 1/12/2018 | | DONE |
|
|
|
Mailed 1-12-18
|
Second Notice | | 11/24/2017 | 12/12/2017 | | DONE |
|
|
|
Mailed 12-13-17
|
First Notice | | 10/28/2017 | 11/14/2017 | | DONE |
|
|
|
Mailed 11-15-17
|
Print Occupancy Form | | | 10/18/2017 | | DONE |
|
|
|
|
Permanent Occupancy | | | 10/18/2017 | | DONE |
|
|
|
|
BLD-Final | 10/17/2017 | 10/18/2017 | 10/17/2017 | A | PASS |
Mike Jordan
|
|
|
Troy Phone #: ###-####. Ok for perm occ. DID NOT HAVE CARD TO SIGN...
|
BLD-Final | 10/16/2017 | 10/16/2017 | 10/16/2017 | P | PART |
Mike Jordan
|
|
|
Troy Phone #: ###-####. Needs to add additional exit sign with directional arrow at secondary exit. Ok for temp occ.
|
FIRE-Final Inspection | 10/16/2017 | 10/16/2017 | 10/16/2017 | P | PASS |
Troy Cobbley
|
|
|
life safety passed
Troy Phone #: ###-####
|
BLD-Final | 10/12/2017 | 10/13/2017 | 10/13/2017 | A | NR |
Mike Jordan
|
|
|
Troy Phone #: ###-####
|
FIRE-Final Inspection | 10/12/2017 | 10/13/2017 | 10/13/2017 | A | FAIL |
Troy Cobbley
|
|
|
Need the smoke evac engineering as discussed, The smoke evac louver did no function when tested, need an additional fire extinguisher in the Sales area, need as additional exit sign at the rear Sales exit door, need an exit sign/emergency light in the rear service area just outside of the Storage area and per Carl the plans need to be resubmitted showing the deleted wall between Storage and the Utility Room.
Troy Phone #: ###-####
|
BLD-Final | 10/12/2017 | 10/12/2017 | 10/12/2017 | P | NR |
Mike Jordan
|
|
|
Troy Phone #: ###-####. Fire/life/safety failed.
|
FIRE-Final Inspection | 10/12/2017 | 10/12/2017 | 10/12/2017 | P | CANC |
Troy Cobbley
|
|
|
To be rescheduled for tomorrow due to the fire alarm not being ready and I need verification from an engineer that the smoke evac system is still functional/installed as designed.
Troy Phone #: ###-####
|
BLD-Framing/Rough-in | 9/26/2017 | 9/26/2017 | 9/26/2017 | P | PASS |
Mike Jordan
|
|
|
Troy Phone #: ###-####. Soffit frming ok.
|
BLD-Framing/Rough-in | 9/21/2017 | 9/21/2017 | 9/21/2017 | P | PASS |
Mike Jordan
|
|
|
Troy Phone #: ###-####. Interior steel stud framed wals only.
|
Plan assigned to (CDM) | 9/8/2017 | 9/8/2017 | 9/21/2017 | | PASS |
Carl D Madsen
|
|
|
Boise Towne Square Mall
|
Routing - PLAN CHECK | 9/8/2017 | | 9/21/2017 | | PASS |
Carl D Madsen
|
|
|
|
1st review completed | | | 9/21/2017 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/21/2017 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 9/21/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 9/21/2017 | | DONE |
|
|
|
Need:
GC form
**Met** Revised value
|
Print Occupancy Form | | | 9/21/2017 | | DONE |
|
|
|
|
Telephone call | | | 9/21/2017 | | DONE |
|
|
|
Spoke with Troy informing him that his permit is ready. Made sure the value was correct before giving him the fee amount for issuance.
|
Issue PAID IN FULL permit | | | 9/21/2017 | | DONE |
|
|
|
|
Plan resubmittals received | | | 9/20/2017 | | DONE |
|
|
|
Two copies of sheets AE101 and AE301 taken to Carl M
|
Plan resubmittals received | | | 9/13/2017 | | DONE |
|
|
|
received two copies of specification sheet (1 pg), and plan sheet AE301; taken to Carl M.
|
Plans ACCEPTED BY PLAN TECH | | | 9/8/2017 | | DONE |
|
|
|
|
Intake Approval | | | 9/8/2017 | | PASS |
Carl D Madsen
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 9/8/2017 | | DONE |
|
|
|
|
Intake Approval | | | 8/16/2017 | | FAIL |
Julie Romig
|
|
|
To complete your application, provide the following:
1. Completed 518 Checklist and any additional items as required by checklist.
2. Drawings must be uploaded as individual sheets. File names should use the City of Boise naming convention, sheet number and brief description (ex. G000-Cover Sheet).
3. Boise Town Square has an existing smoke control system, which must be maintained. Drawings must show cfm calculations for smoke control system with airflow design and location/size of transfer grilles.
4. Provide structural calculations or ES report for new coiling grill and grill attachment.
5. Completed Form 310 if any special inspections are required.
6. COMcheck forms for new interior lighting and new mechanical heating/cooling units.
|
Application received | | | 8/14/2017 | | DONE |
|
|
|
Application submitted via PDS Online on Aug 14 2017 2:31PM
|