Permit Information
Permit NumberBLD17-02932
StatusFinaled
Name SLOANCO LLC
Site Address 6828 W MELROSE ST
Project NameSloanCo - Office, Fab, Storage
Customer Number 
ePlanReviewYes
Description
(SLOANCO – OFFICE, FABRICATION, WAREHOUSE – NEW BUILDING AND TENANT IMPROVEMENT) (DRH17-00279) The fire sprinkler system will be used for building area increase, story increase, and for fire area. To construct a new 17,645 square foot building (14,659 square feet 1st story and 2,986 square feet 2nd story) to be used for office, fabrication, and storage. A grading permit (GRD17-00044) was issued earlier. A foundation permit (BLD17-03338) was also issued earlier and was for excavation, fill compaction, footings, and foundations for the building only. To erect a pre-engineered metal building with a wood framed 2 story office component below the roof of the metal building. The metal building work is to include steel columns, steel beams, steel purlins, metal siding, metal roof deck, and steel bracing. The wood framed office work is to include wood exterior bearing and nonbearing walls, stone veneer, 3-part stucco system, metal siding, wood interior bearing and nonbearing walls, wood floor trusses, wood floor sheathing, wood shear walls, an interior stairway, an exterior steel stairway, exterior doors, exterior windows, interior doors, interior windows, millwork, and finishes. Special Inspection is required for soils, concrete, welding, and bolting. Welding, painting, spraying, and coating operations done within this building as part of its use are required to be in compliance with the Fire Code. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. A separate permit is required for storage racks exceeding 8 feet in height. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  11/16/2018 DONE
Third Notice 10/17/201811/7/2018 DONE
mailed 11-12
Second Notice 9/17/201810/12/2018 DONE
mailed 10-15-18
First Notice 9/10/20189/7/2018 DONE
mailed 9-10-18
Permanent Occupancy  8/31/2018 DONE
BLD-Final8/29/20188/30/20188/30/2018APASS
DetailsMike Jordan
Greg Phone #: ###-####. All issues resolved. ok for perm occ.
Temporary Occupancy7/18/201810/16/20187/18/2018 DONE
DetailsCandy A. Nichols
Jason B ok'd extension for Temp C of O
Telephone call  7/17/2018 DONE
called Ben to let know the TCO is about to expire-he will email Jason Blais
BLD-Aging Inspection7/11/20187/11/20187/11/2018 PEND
DetailsMike Jordan
pending zoning and fees due.
Routing PW Street Lights5/25/2018 5/25/2018 PASS
DetailsTom Marshall
Street lights was missed durning normal review and was caught in April and is now being installed.
Temporary Occupancy4/20/20187/19/20184/20/2018 DONE
DetailsChristina Prado
PWK has fees due. Please don't issue the CO until they are paid. PWK18-00151
BLD-Final4/19/20184/19/20184/19/2018PPART
DetailsMike Jordan
Ok for temp occ. Still needs to install a permanant cane guard.
BLD-Final4/18/20184/19/20184/19/2018AFAIL
DetailsMike Jordan
Greg Phone #: ###-####. Provide cane guard on exterior stairs. Noted open risers on exterior stairs exceed 4 inches. Also needs final letter from special insection.
PubWorks Occupancy Approval4/19/20184/19/20184/19/2018 DONE
DetailsTiffany Lowery
Engineer letter for drainage received, and bonding for street lights received.
FIRE-Final Inspection4/17/20184/18/20184/18/2018APASS
DetailsTroy Cobbley
life safety passed

Greg Phone #: ###-####
Plan Reviewer's activity  4/18/2018 DONE
DetailsErika Akin
Call from inspector. Hydrant not installed as shown on plan sheet A101 as refenced in review but as shown on plan sheet C2.1. Location okay.
FIRE-Final Inspection4/17/20184/17/20184/17/2018PCANC
DetailsTroy Cobbley
Greg Phone #: ###-####
BLD-Final4/16/20184/16/20184/16/2018PNR
DetailsMike Jordan
Greg -structural final occupancy Phone #: ###-####
FIRE-Final Inspection4/16/20184/16/20184/16/2018PFAIL
DetailsJim Page
Fire extinguishers are mounted to high, extinguishers need to be lowered to 48inches or below. Provide signage for fire sprinkler riser room/FACP. Repair exit discharge emergency lighting, exterior emergency lights did not work on secondary power supply.
Zoning Approval4/16/20184/16/20184/16/2018 PASS
DetailsKatelyn Menuge
BLD-Ceiling Grid Inspection3/13/20183/14/20183/14/2018APART
DetailsMike Jordan
Ed Phone #: ###-####. Grid ok 1st and 2nd floors. Pending electrical and mech. rough in inspections.
FIRE-Conference3/7/20183/7/20183/7/2018PDONE
DetailsTroy Cobbley
I stopped and discussed possible gate requirements with the job superintendant. Per scott the reduced gate width is not a factor and the electric gates (submitted as manual) will not require Opticon but a means to access them shall be required to be provided in the Knox key box
BLD-Energy code compliance3/6/20183/6/20183/6/2018PPASS
DetailsBrandon Shaw
Ed Phone #: ###-####
BLD-Energy code compliance2/9/20182/9/20182/9/2018PPASS
DetailsMike Jordan
Ed Phone #: ###-####
BLD-Energy code compliance2/6/20182/7/20182/7/2018PPASS
DetailsJim Storey
Ed Phone #: ###-#### 2nd floor ok/ first floor ok to insulate pending fir spk hard ceillings ok
BLD-Framing/Rough-in2/2/20182/5/20182/5/2018APASS
DetailsMike Jordan
Ed Phone #: ###-####. Interior and exterior wood framed walls 2nd. floor only ok. No ceiling or hardlids at this time.
BLD-Framing/Rough-in2/1/20182/2/20182/2/2018ACANC
DetailsMike Jordan
ED SLOAN Phone #: ###-####. Needs electrical rough in inspection and airseal pack .
BLD-Framing/Rough-in1/10/20181/11/20181/11/2018APASS
DetailsMike Jordan
Ed Phone #: ###-####. Shear walls ok.
Telephone call  12/11/2017 DONE
called Edward to let know that there are still fees due and taht we can not issue the permit until they are payed-couldn't leave a message because the box is full-will email him
Issue PAID IN FULL permit  12/11/2017 DONE
Print Occupancy Form  12/11/2017 DONE
Permit Ready to Issue  12/1/2017 DONE
Need:
Revised value
GC form
ACHD - met
RP - met (ESC17-01077) this is issued already so please don't re issue it
Plan assigned to (CJW)9/14/20179/14/201711/30/2017 PASS
DetailsCarl Westfall
(2nd done) (Oct 18 - 25 days) (92 sheets) Sloan Securities (new BLDG)
Routing - PLAN CHECK11/29/2017 11/30/2017 PASS
DetailsCarl Westfall
PLANS/APPL TAKEN TO FRONT DESK  11/30/2017 DONE
Plan resubmittals received  11/29/2017 DONE
Routing - Design Review11/29/2017 11/29/2017 PASS
DetailsKatelyn Menuge
DRH17-00214 and DRH17-00279
Routing - Design Review11/14/2017 11/20/2017 FAIL
DetailsKatelyn Menuge
Light poles cannot be within planter islands containing trees.
Plan resubmittals requested  11/20/2017 DONE
Routing - MECHANICAL11/14/2017 11/15/2017 PASS
DetailsTroy James
Please resolve your changemarks
Route to Impact Fee Review11/4/201711/7/201711/14/2017 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - PLAN CHECK11/14/2017 11/14/2017 PASS
DetailsCarl Westfall
Drawings approved
Plan resubmittals received  11/14/2017 DONE
Plan resubmittals requested  11/13/2017 DONE
Routing - MECHANICAL11/7/2017 11/13/2017 PASS
DetailsTroy James
Routing Off Site - STRUCTURAL11/7/2017 11/13/2017 PASS
DetailsCarl Westfall
Jan Welch (Stapley)
Routing - PLAN CHECK11/7/2017 11/8/2017 PASS
DetailsCarl Westfall
Pending structural. The final Item was resolved by uploading an Emailed drawing.
Routing - Design Review11/7/2017 11/8/2017 FAIL
DetailsKatelyn Menuge
Need light poles moved out of landscape planters that contain trees.
Routing - PLAN CHECK11/6/2017 11/7/2017 FAIL
DetailsCarl Westfall
Revisions required to correct return air path
Plan resubmittals received  11/6/2017 DONE
1st review completed  11/4/2017 DONE
Plan resubmittals requested  11/4/2017 DONE
Routing - PLAN CHECK9/14/2017 11/4/2017 FAIL
DetailsCarl Westfall
Revised drawings required
Routing Off Site - STRUCTURAL9/14/2017 10/2/2017 FAIL
DetailsCarl Westfall
Jan Welch (Stapley)
Routing - FIRE9/14/20179/14/20179/25/2017 PASS
DetailsScott Arellano
Attached plan review comments to plans.
Routing PW Environmental9/14/2017 9/25/2017 PASS
DetailsRick Christenson
Routing PW Sewer Design9/14/2017 9/22/2017 PASS
DetailsKyle S. Rosenmeyer
Routing PW Drainage9/14/2017 9/20/2017 PASS
DetailsJason C. Taylor
Routing - PUBLIC WORKS9/14/2017 9/20/2017 PASS
DetailsMorgan Webb
Be sure to Route to Jason Taylor
Routing - Erosion and Sediment9/14/2017 9/19/2017 PASS
DetailsAndy J. Long
ESC permit for project already issued with GRD permit. See ESC17-01077. No duplicate ESC permit required.
Routing - MECHANICAL9/14/2017 9/18/2017 FAIL
DetailsTroy James
Routing - PLUMBING9/14/2017 9/15/2017 PASS
DetailsBill VanDegrift
red lines
1) provide 12.56" of venting through the roof
2) sewer service is schedule 40 PVC
Routing - PLANNING9/14/2017 9/15/2017 PASS
DetailsNicolette Womack
Routing - PLANNING Land Div9/14/2017 9/15/2017 PASS
DetailsTodd Tucker
Routing - Addressing9/14/2017 9/15/2017 PASS
DetailsDoug Chausow
Routing PW Solid Waste9/14/2017 9/15/2017 PASS
DetailsEvan Carpenter
Enclosure gates must be shown on the plans; enclosure needs to face north to ensure the requirement of 50 feet of clearance in front of enclosure is met
Routing - Design Review9/14/2017 9/15/2017 FAIL
DetailsKatelyn Menuge
Corrections Required - DRH17-00279
Plan Reviewer's activity  9/14/2017 PASS
Plan intake approved. Accepting this project for permit submission is not an endorsement of the foundation design or the soils work proposed.
Intake Approval  9/14/2017 PASS
Routing PW Sewer Rating9/14/2017 9/14/2017 PASS
DetailsMorgan Webb
Intake Approval  8/28/2017 FAIL
(8-28-17) Please see the circled items in the plan intake checklist. Please resolve each item as directed. Provide a detailed grading plan showing the detailed recommendations of the Geo Tech Engineer on the drawings. Provide a complete structural package for the metal building including connection details. Provide complete engineering calculations that validate the metal building drawings. CJW
Plan Reviewer's activity  8/17/2017  
Make sure this project is routed to Jason Taylor. "Monitoring and observation of all earthwork activities by and MTI geotechnical engineer is mandatory."
Intake Approval  8/17/2017 FAIL
(8-17-17) Please see the circled items in the plan intake checklist. Please resolve each item as directed. CJW
Application received  8/16/2017 DONE
Application submitted via PDS Online on Aug 16 2017 2:11PM