First Notice | | 5/18/2018 | 7/10/2018 | | DONE |
|
|
|
mailed 7-11-18
|
Permanent Occupancy | | | 5/8/2018 | | DONE |
|
|
|
|
BLD-Conference | 5/4/2018 | 5/4/2018 | 5/4/2018 | P | CANC |
Mike Jordan
|
|
|
Cody Phone #: ###-####
|
BLD-Final | 5/4/2018 | 5/4/2018 | 5/4/2018 | P | PASS |
Mike Jordan
|
|
|
Cody Phone #: ###-####. OK for perm occ.
|
FIRE-Final Inspection | 5/4/2018 | 5/4/2018 | 5/4/2018 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed
|
Temporary Occupancy | 5/2/2018 | 7/31/2018 | 5/2/2018 | | DONE |
Candy A. Nichols
|
|
|
Jason Blais ok'd 30 day extension on the temp c of o
|
BLD-Aging Inspection | 4/24/2018 | 4/24/2018 | 4/24/2018 | | PEND |
Mike Jordan
|
|
|
|
BLD-Final | 2/1/2018 | 2/2/2018 | 2/2/2018 | A | PART |
Mike Jordan
|
|
|
BYRON Phone #: ###-####. Ok for temp occ.
|
FIRE-Final Inspection | 2/1/2018 | 2/2/2018 | 2/2/2018 | A | PART |
Troy Cobbley
|
|
|
A temporary occupancy is being given until the exit discharge light at the main exit is installed and the shell/core permit is finaled.
BYRON Phone #: ###-####
|
Temporary Occupancy | 2/2/2018 | 5/3/2018 | 2/2/2018 | | DONE |
Brittany Hill
|
|
|
|
FIRE-Final Inspection | 1/31/2018 | 2/1/2018 | 2/1/2018 | A | FAIL |
Troy Cobbley
|
|
|
Need the project related fire alarm permit addressed. Will be ok for a temp when the fire alarm permit is finaled. For a final, the exit discharge light above the front exit will need to be installed.
Byron Phone #: ###-####
|
BLD-Final | 1/30/2018 | 1/31/2018 | 1/31/2018 | P | FAIL |
Mike Jordan
|
|
|
Egor Phone #: ###-####. Vertical grab abrs in restrooms mounted to far from rear wall. Mount ADA restromm signs on wall. Provide exterior landing at man door. Post occupant load sing in meeting room. Install aditional handrail on new stairs. Sheetrock under new stairs. Pedestrian protection Overhead, required at main entry and man door while new facade work is taking place.
|
FIRE-Final Inspection | 1/30/2018 | 1/31/2018 | 1/31/2018 | P | CANC |
Troy Cobbley
|
|
|
Egor Phone #: ###-####
|
Zoning Approval | 1/30/2018 | 1/30/2018 | 1/30/2018 | | DONE |
Katelyn Menuge
|
|
|
|
Print Occupancy Form | | | 1/26/2018 | | DONE |
|
|
|
|
BLD-Energy code compliance | 12/27/2017 | 12/28/2017 | 12/28/2017 | A | PASS |
Mike Jordan
|
|
|
Jim Phone #: ###-####
|
BLD-Framing/Rough-in | 12/28/2017 | 12/28/2017 | 12/28/2017 | A | PASS |
Mike Jordan
|
|
|
Jim Phone #: ###-####. New LVL beams for mezz support ok.
|
BLD-Framing/Rough-in | 12/8/2017 | 12/8/2017 | 12/8/2017 | P | PART |
Brandon Shaw
|
|
|
Main entrance and Mezz framing at later date
|
BLD-Framing/Rough-in | 12/6/2017 | 12/6/2017 | 12/6/2017 | P | PART |
Mike Jordan
|
|
|
Igor Phone #: ###-####. No city approved plans on site. Ok to one side only. Will call in for reinspection tomorrow in the pm with approved set of city plans.
|
Meeting | | | 11/13/2017 | | DONE |
|
|
|
emailed Jim again that i still need the building permit signed
|
Print Occupancy Form | | | 11/9/2017 | | DONE |
|
|
|
|
Meeting | | | 11/9/2017 | | DONE |
|
|
|
as per Doug in addressing-permit was turned in with 10477 address but needs to be 10491-it was addressed incorrectly as 10487. I talked to Jim with Datum and will email him so he can sign the building permit with the correct address-talked to Jim Raines again-he is aware of the address change and will get the permit signed by the correct person and email it back to me
|
(F) Reprint permit | | | 11/9/2017 | | DONE |
|
|
|
|
(F) Reprint permit | | | 11/6/2017 | | DONE |
|
|
|
|
Telephone call | | | 11/6/2017 | | DONE |
|
|
|
emailed (attached the permit again) that we need the building permit signed and sent back
|
Issue PAID IN FULL permit | | | 10/30/2017 | | DONE |
|
|
|
|
Print Occupancy Form | | | 10/30/2017 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/17/2017 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 10/17/2017 | | DONE |
|
|
|
ALL MET-Need
GC Form-MET
Revised Cert of Value-MET
|
Plan assigned to (JAR) | 9/16/2017 | 9/16/2017 | 10/16/2017 | | DONE |
Julie Romig
|
|
|
**1st Rev Comp - 2nd Rec'd 10/09 - L2 Dead-On Archery
|
Routing - PLAN CHECK | 10/9/2017 | | 10/16/2017 | | PASS |
Julie Romig
|
|
|
|
Route to Impact Fee Review | 9/29/2017 | 10/2/2017 | 10/2/2017 | | PASS |
Eric Bilimoria
|
|
|
Review requested for Commercial Permit
|
Routing - PLAN CHECK | 9/16/2017 | | 9/29/2017 | | FAIL |
Julie Romig
|
|
|
|
Routing Off Site - STRUCTURAL | 9/16/2017 | | 9/29/2017 | | PASS |
Julie Romig
|
|
|
|
1st review completed | | | 9/29/2017 | | FAIL |
Julie Romig
|
|
|
|
Routing - FIRE | 9/16/2017 | 9/16/2017 | 9/25/2017 | | PASS |
Scott Arellano
|
|
|
Review comments attached to case
|
Routing - MECHANICAL | 9/16/2017 | | 9/19/2017 | | PASS |
Troy James
|
|
|
Ductwork to existing RTU's and new exhaust fans to restrooms.
|
Routing - PLUMBING | 9/16/2017 | | 9/18/2017 | | PASS |
Daryl Spivey
|
|
|
Per plan and ISPC.
|
Routing - Addressing | 9/16/2017 | | 9/18/2017 | | PASS |
Doug Chausow
|
|
|
Address updated to: 10491 W Fairview Ave
|
Routing - PUBLIC WORKS | 9/16/2017 | | 9/18/2017 | | PASS |
Morgan Webb
|
|
|
|
Routing - Design Review | 9/16/2017 | | 9/18/2017 | | PASS |
Sarah Schafer
|
|
|
|
Intake Approval | | | 9/16/2017 | | PASS |
Javier Guzman
|
|
|
|
Intake Approval | | | 9/13/2017 | | FAIL |
Rob Patrick
|
|
|
|
Application received | | | 9/11/2017 | | DONE |
|
|
|
Application submitted via PDS Online on Sep 11 2017 1:30AM
|
BLD-Final | 1/31/2018 | 2/1/2018 | | P | |
Mike Jordan
|
|
|
Byron Phone #: ###-####
|