Permit Information
Permit NumberBLD17-03632
StatusFinaled
Name STEED CONSTRUCTION
Site Address 555 S COLE RD
Project NameLocker Room Addition
Customer Number 
ePlanReviewYes
Description
(INTERMOUNTAIN GAS – LOCKER ROOM ADDITION TO THE WELDING SHOP – NORTH SIDE) (DRH17-00258) This building does not have a fire sprinkler system. To construct a new 265 square foot toilet room, shower room, and locker room addition to an existing 2,450 square foot building used as a welding shop and storage room. After the addition, this building will have a total floor area of about 2,715 square feet. Work is to include concrete footings, concrete foundations, concrete slab on grade, masonry exterior walls, wood roof trusses, a gypsum board ceiling with insulation installed on top of the ceiling and the attic vented to the outside, wood roof sheathing, a standing seam metal roof covering on a 2:12 sloped shed roof, wall furring and cavity wall insulation installed on the inside of masonry exterior walls, a toilet room accessible to the disabled, a shower room with a transfer shower accessible to the disabled, a locker room accessible to the disabled, interior doors, and finishes. The new addition is required to be served by a route that is accessible to the disabled. A new opening in an existing masonry wall will be created for access between the existing building and the building addition. A steel header, steel jambs, and steel columns to resist out-of-plane lateral loads will be provided at the new opening. A new door will be installed in the opening. Special Inspection is required for soils, concrete, masonry, anchors post-installed in hardened concrete and masonry, and welding. Work also includes a 16’ x 30’ trash enclosure that is open to the sky with concrete footings, concrete foundations, masonry walls 8 feet tall, concrete slab on grade, a steel side hinged personnel door, steel gates, and bollards. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 2/12/20193/11/2019 DONE
mailed 3-12 with first follow up
First Follow up  3/11/2019 DONE
Third Notice 1/13/20192/7/2019 DONE
mailed 2-11-19
Third Notice 12/19/20181/8/2019 DONE
mailed 1-11-19
Second Notice 11/18/201812/14/2018 DONE
mailed 12-17
First Notice 11/8/201811/8/2018 DONE
mailed 11-12
Permanent Occupancy  10/29/2018 DONE
BLD-Final9/27/20189/28/20189/28/2018APASS
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. OK for perm occ.
Routing - PUBLIC WORKS GRADING9/26/2018 9/26/2018 PASS
DetailsBrian Murphy
BLD-Final9/19/20189/19/20189/19/2018PPEND
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. Need final inspection letter from special inspection agency.
Zoning Approval9/18/20189/18/20189/18/2018 DONE
DetailsAndrea Tuning
FIRE-Final Inspection8/29/20188/30/20188/30/2018APASS
DetailsTroy Cobbley
life safety passed


Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman
BLD-Wall cover7/17/20187/18/20187/18/2018APASS
DetailsMike Jordan
Jim Phone #: ###-#### Inspection requested via web by Jim Wellman
BLD-Energy code compliance7/18/20187/18/20187/18/2018APASS
DetailsMike Jordan
Jim Phone #: ###-#### Inspection requested via web by Jim Wellman
BLD-Framing/Rough-in7/17/20187/18/20187/18/2018APASS
DetailsMike Jordan
Jim Phone #: ###-#### Inspection requested via web by Jim Wellman. All issues have been resolved. Ok to insulate.
BLD-Framing/Rough-in7/11/20187/12/20187/12/2018PFAIL
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman..Complete airseal pack. Install remainder of simpson straps from masonry wall ro new construction. Noted that ADA transfer shower has been installed incorrectly. Seat side does not provide the required 12 inches of clearance beyond.
BLD-Footing5/6/20185/7/20185/7/2018APART
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. Work in pogress. Will have special inspection.
Print Occupancy Form  3/27/2018 DONE
Issue PAID IN FULL permit  3/27/2018 DONE
Expiration Notice3/20/20184/10/20183/20/2018 DONE
DetailsBrittany Hill
Plan assigned to (CJW)10/19/201710/19/201712/29/2017 PASS
DetailsCarl Westfall
(1st done) (Nov 22 - 25 days) (31 sheets) Intermountain Gas Restroom addition
Routing - PLAN CHECK12/28/2017 12/29/2017 PASS
DetailsCarl Westfall
Drawings approved
PLANS/APPL TAKEN TO FRONT DESK  12/29/2017 DONE
Permit Ready to Issue  12/29/2017 DONE
Need
GC Form - met
Revised Cert of Value - met
Plan resubmittals received  12/28/2017 DONE
DetailsCarl Westfall
Route to Impact Fee Review12/18/201712/21/201712/19/2017 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - PLAN CHECK10/19/2017 12/18/2017 FAIL
DetailsCarl Westfall
Resubmittal required
1st review completed  12/18/2017 DONE
Plan resubmittals requested  12/18/2017 DONE
Routing Off Site - STRUCTURAL10/19/2017 11/3/2017 PASS
DetailsCarl Westfall
Jordan Terry (KPFF)
Routing - FIRE10/19/201710/19/201710/23/2017 PASS
DetailsScott Arellano
Attached review comments to case
Routing PW Grading-Hillside10/20/2017 10/23/2017 PASS
DetailsMelissa Jannusch


Drainage and grading approved under GRD17-00025 and ODI 3633

Call ###-####549 for a drainage system inspection. Schedule 24 hours before desired inspection time.

A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please allow 24 hours for subgrade approval processing. Call Melissa Jannusch at ###-####

Routing - Erosion and Sediment10/19/2017 10/23/2017 PASS
DetailsMichael Zawacki
No new ESCP permit needed. Reference ESC17-00657
Routing - Addressing10/19/2017 10/20/2017 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS10/19/2017 10/20/2017 PASS
DetailsRachael Beierle
WEST BOISE SEWER DISTRICT GRADING PASSED UNDER GRD17-00025
Routing - MECHANICAL10/19/2017 10/20/2017 PASS
DetailsTroy James
Routing - PLUMBING10/19/2017 10/20/2017 PASS
DetailsBill VanDegrift
per plans and ISPC
Routing - Design Review10/19/2017 10/20/2017 PASS
DetailsAndrea Tuning
Routing - PLANNING10/19/2017 10/19/2017 PASS
DetailsCeline Acord
No review required
Routing - PLANNING Land Div10/19/2017 10/19/2017 PASS
DetailsTodd Tucker
Was not routed to Land Division. Evidently the legality of the lot is obvious.
Intake Approval  10/19/2017 PASS
Intake Approval  10/9/2017 FAIL
Application received  10/6/2017 DONE
Application submitted via PDS Online on Oct 6 2017 3:16PM