Permit Information
Permit NumberBLD18-00301
StatusFinaled
Name GREEN TEAM CONSTRUCTION LLC
Site Address 1320 N HARTMAN ST Unit: H-1
Project NameCentral Pointe Apts - Repair
Customer Number 
ePlanReviewNo
Description
(CENTRAL POINTE APARTMENTS – BUILDING H – UNITS H1, H2, H3, H4, H5, H6, AND H8 – FIRE REPAIR) This apartment building does not have a fire sprinkler system. To repair 7 residential apartments damaged by fire located on the 1st and 2nd stories of an existing 8 unit residential apartment building having a total floor area of about 6,105 square feet (3,140 square feet 1st story and 2,965 square feet 2nd story). This building has 4 dwelling units per story. Only unit H7 on the 1st story was not damaged. Demolition work includes removing interior drywall, exterior siding, fire damaged studs, fire damaged trusses, roof sheathing, etc. An inspection is required by a Boise City Structural Inspector before any structural members are demolished. To repair the apartment building based on the original drawings. Existing construction in compliance with the 1970 UBC is allowed to remain. New construction is required to comply with the 2015 IBC. The existing concrete footings and concrete foundations will remain. Work is to include the repair of exterior and interior bearing/shear walls, 1-hr dwelling unit separations (horizontal and vertical), 1-hr walls supporting the 1-hr floor between the 1st and 2nd stories, insulation, drywall, exterior siding, stairway, stairway separated from the rest of the building as a 1-hr corridor, windows, doors, engineered trusses, draftstops, roof sheathing, roof shingles, etc. New work is required to comply with the 2015 IBC, with the plan review report, and with all other applicable codes and ordinances. This permit is intended to restore the original approval to occupy. A fire sprinkler system will not be installed. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/13/20187/13/20187/13/2018PPASS
DetailsMike Jordan
Will Phone #: ###-####. ok for perm occ.
DOC - Permit Finaled7/13/20187/13/20187/13/2018PPASS
DetailsMike Jordan
BLD-Final7/11/20187/12/20187/12/2018PFAIL
DetailsMike Jordan
Will Phone #: ###-####. Provide code compliant handrails on the new stairs that have been replced.
FIRE-Final Inspection7/11/20187/12/20187/12/2018APASS
DetailsTroy Cobbley
life safety passed

Will Phone #: ###-####
BLD-Other6/11/20186/11/20186/11/2018PPASS
DetailsMike Jordan
fire wall // Will Phone #: ###-####. 2 layers of 5/8 type x in entry way walls and lid ok.
BLD-Energy code compliance4/3/20184/3/20184/3/2018PPASS
DetailsMike Jordan
call for access 30 mins prior-William Phone #: ###-####. Truss engineering was on site.
BLD-Framing/Rough-in3/30/20183/30/20183/30/2018PPASS
DetailsDave Hannah
Will Phone #: ###-#### ok insulate need to look at truss ingineering at insulation inspection
BLD-Conference2/7/20182/8/20182/8/2018ADONE
DetailsMike Jordan
WIlliam Phone #: ###-####
Issue PAID IN FULL permit  2/7/2018 DONE
Plan assigned to (CJW)1/29/20181/29/20182/6/2018 PASS
DetailsCarl Westfall
Routing - PLAN CHECK1/29/2018 2/6/2018 PASS
DetailsCarl Westfall
1st review completed  2/6/2018 DONE
PLANS/APPL TAKEN TO FRONT DESK  2/6/2018 DONE
Permit Ready to Issue  2/6/2018 DONE
Need GC form
Inspection Record Card- Bld  2/6/2018 DONE
Inspection Record Card- Bld  2/6/2018 DONE
Plans ACCEPTED BY PLAN TECH  1/29/2018 DONE
Intake Approval  1/29/2018 PASS
Recd Pcfee & Taken To Pln CK  1/29/2018 DONE
First Notice7/13/20187/13/2018   
DetailsMike Jordan
Application received 1/29/2018