Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD18-00342
StatusFinaled
Name LAMAR ADVERTISING CORP
Site Address 11000 W FAIRVIEW AVE
Project NameBillboard Sign
Customer Number 
ePlanReviewYes
Description
(BILLBOARD SIGN) (CUP17-00077) To relocate a 40’- 0” tall billboard sign having a 10’- 6” high x 22’- 8” wide face on two sides (28’- 0” from grade to the underside of the sign). The new location will be on the North side of Fairview just East of N. Wildwood Street. The sign was removed from its former location (i.e. the Southeast corner of Fairview and Shamrock) under permit BLD17-02086. Work includes a 3’- 0” diameter by 17’- 6” deep concrete footing (or 8’- 0” by 4’- 0” by 11’- 0” deep reinforced concrete cube footing), a 20” diameter steel column (or 3’- 0” diameter steel column if the cube footing is used), a 10” diameter torsion pipe, steel gusset plates, steel beam uprights, steel sign stringers, steel beams, steel catwalks, steel guards, safety cable, a steel ladder, steel bolts, and two face panels. Special Inspection is required to verify the excavation size, for bolting, and for any field welding. Components are required to be shop fabricated by an approved fabricator (including welds). The work is required to comply with the approved drawings, with the structural design, and with all applicable codes and ordinances. All attachments are required to be sufficient to resist gravity, wind, and seismic loads with appropriate safety factors considered. A separate electrical permit is required for electrical work. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Footing4/6/20184/9/20184/9/2018APASS
DetailsJim Sly
required special inspections of footing and high strength bolts done by third party (MTI) city inspector will be e-mailed approved inspection reports by MTI. Please contact Rick Linehan with Lamar advertising. rilinehan@lamar.com or ###-####. Rick will provide all materials. Phone #: ###-#### Inspection requested via web by Robert Hamlin
Viewed MTI report # B180520c
DOC - Permit Finaled4/9/20184/9/20184/9/2018PPASS
DetailsJim Sly
OVERRIDE  2/13/2018  
Issue PAID IN FULL permit  2/13/2018 DONE
Plan assigned to (CJW)2/6/2018 2/13/2018 PASS
DetailsCarl Westfall
Routing - PLAN CHECK2/6/2018 2/13/2018 PASS
DetailsCarl Westfall
1st review completed  2/13/2018 DONE
PLANS/APPL TAKEN TO FRONT DESK  2/13/2018 DONE
Permit Ready to Issue  2/13/2018 DONE
fees due on ESC permit. (new footing is over 2 cy)
Routing - PLANNING2/8/2018 2/8/2018 PASS
DetailsBrent Moore
Meeting  2/6/2018 DONE
came in and paid bld fee. Started review, but will need to pay esc fee prior to issuance of permit.
Application received  1/31/2018 DONE
Application submitted via PDS Online on Jan 31 2018 5:00PM
First Notice4/9/20184/9/2018   
DetailsJim Sly