Information based on query as of Thursday, July 4, 2024.
Permit Information
Permit NumberBLD18-00842
StatusFinaled
Name PETRA INC
Site Address 1449 S DAVID LN Unit: 110
Project NameSchroeder Office
Customer Number 
ePlanReviewYes
Description
(SCHROEDER OFFICE BUILDING) (DRH18-00008) (2-5-20 PLAN MODIFICATION TO REDESIGN THE MECHANICAL AND PLUMBING SYSTEMS DUE TO REMOVING THE BASEMENT AND REPLACING IT WITH A CRAWLSPACE. THE CRAWLSPACE WILL BE MECHANICALLY VENTED.) This building does not have a fire sprinkler system. The basement storage room was deleted from the scope of work. To construct a one story office building having a total floor area of about 2,578 square feet with a crawlspace. Two tenant spaces will be created on the 1st story (Suite A or #110 - 1,651 square feet and Suite B or # 120 - 898 square feet). Work is to include concrete footings, concrete stem walls, wood joist floor system recessed down into the perimeter concrete stem walls with wood sheathing, wood stud bearing pony walls to support the floor, 2x6 wood stud exterior bearing walls with gypsum wall board on the inside, wood stud shear walls with structural sheathing and hold downs, exterior stucco wall finish, exterior stone veneer wall finish, exterior windows, exterior doors, wood roof structure using energy trusses with a vented attic, concrete tile roof covering, metal roof covering, roof gutters and downspouts, interior non-bearing walls with gypsum wall board, 2 single-user toilet rooms accessible to the disabled, interior doors, interior windows, millwork, and finishes. Special Inspection is required for soils. The design for the roof trusses is a deferred submittal item. This permit is intended to establish a Certificate of Occupancy for Schroeder Office in Suite 110. A separate permit shall be applied for and issued to establish a Certificate of Occupancy for Suite 120. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  8/13/2020 DONE
email to Christina to mail out.
Telephone call  7/24/2020 DONE
final values received and saved to doc
Print Statement  7/24/2020 DONE
Second Notice 5/17/20207/9/2020 DONE
mailed 7-9-2020
First Notice 5/7/20205/7/2020 DONE
mailed 5-8-2020
Permanent Occupancy  4/27/2020 DONE
PubWorks Occupancy Approval4/24/20204/24/20204/24/2020 DONE
DetailsTiffany Lowery
BLD-Final4/20/20204/21/20204/21/2020APASS
DetailsJim Storey
screened // Steve Phone #: ###-#### final ok pending sign offs p$z/achd/pw (TCH 4-27-20 inspections signed off)
Zoning Approval4/21/20204/21/20204/21/2020 DONE
DetailsKayCee Babb
FIRE-Final Inspection4/14/20204/15/20204/15/2020APASS
DetailsJim Page
Previously noted item has been corrected, no fire sprinklers, no fire alarms, fire extinguishers are placed with current inspection tags. Permenant addressing is on site, GC will verify configuration of numbering with tenant (vertical or horizontal) after verification addressing will be installed. Signature provided on permit sign off card.

Screened- Steve Phone #: ###-####
BLD-Final4/13/20204/14/20204/14/2020ANR
DetailsBrandon Shaw
See fire/life...
FIRE-Final Inspection4/14/20204/14/20204/14/2020PFAIL
DetailsJim Page
Emergency lights on the northeast side of the building did not function when AC power was isolated.

Screened- Steve Phone #: ###-####
BLD-Energy code compliance2/28/20203/2/20203/2/2020APART
DetailsJim Storey
Steve Phone #: ###-#### attic cert at final.
BLD-Energy code compliance2/12/20202/12/20202/12/2020PPASS
DetailsJim Storey
Steve- plan mod on Hvac and Plumbing Phone #: ###-####
BLD-Energy code compliance2/11/20202/12/20202/12/2020ADEFR
DetailsJim Storey
Steve- plan mod on Hvac and Plumbing Phone #: ###-####
BLD-Framing/Rough-in2/11/20202/11/20202/11/2020PPART
DetailsJim Storey
Steve- plan mod on Hvac and Plumbing Phone #: ###-#### web braces a3.a4 b3.b3 6 in oc 80% top of trusses
OVERRIDE  2/11/2020  
Plan assigned to (CJW)1/31/20201/31/20202/11/2020 PASS
DetailsCarl Westfall
plan mod (schroeder office) (routed to staff)
CHANGE STATUS TO (ISS)  2/11/2020 DONE
plan mod
Permit Ready to Issue  2/11/2020 DONE
plan mod approved- fees due
Plan Reviewer's activity  2/11/2020 PASS
2nd plan mod approved
Routing - MECHANICAL2/5/2020 2/10/2020 PASS
DetailsTroy James
Routing - PLUMBING2/5/2020 2/10/2020 PASS
DetailsDaryl Spivey
Per plan and ISPC.
BLD-Framing/Rough-in2/7/20202/7/20202/7/2020PPASS
DetailsJim Storey
Steve- (plan mod for MECHANICAL) inspection for sealing Phone #: ###-#### air seal ok/ framing ok pending truss engineering/ ok to insulate.
BLD-Framing/Rough-in2/3/20202/6/20202/6/2020ANR
DetailsJim Storey
Steve Phone #: ###-####
Routing - PLAN CHECK2/5/2020 2/5/2020 PASS
DetailsCarl Westfall
Plan mod intake review and plan mod both approved. Drawings routed.
Routing - PLAN CHECK2/3/2020 2/4/2020 FAIL
DetailsCarl Westfall
Plan mod 2nd plan intake review failed for the same reasons.
Routing - PLAN CHECK1/31/2020 2/3/2020 FAIL
Failed the plan intake review for the 2nd plan mod. Deleted 6 sheets that were mostly white space and garbled. Called the Architect and asked him to try again. The plan mod was submitted late on a Friday before a weekend.
Plan Modification Accepted  1/31/2020 DONE
DetailsCarl Westfall
Plan Mod for mechanicals per Trey Hoff

Mod to sheets M0.0 M0.1 M0.2 M1.1 M2.0 P1.1 P2.1 P3.0
BLD-Framing/Rough-in1/27/20201/28/20201/28/2020ANR
DetailsDave Hannah
Steve Phone #: ###-####
BLD-Framing/Rough-in1/21/20201/22/20201/22/2020APASS
DetailsJim Storey
Sheer & Roof Sheathing - Steve Phone #: ###-####
BLD-Foundation1/6/20201/7/20201/7/2020APASS
DetailsJim Storey
Dave - waterproofing Phone #: ###-####
BLD-Foundation12/27/201912/31/201912/31/2019ACANC
DetailsDave Hannah
Steve - rebar Phone #: ###-####
BLD-Footing12/23/201912/27/201912/27/2019APASS
DetailsBrandon Shaw
Steve Phone #: ###-####
BLD-Footing12/20/201912/24/201912/24/2019APASS
DetailsBrandon Shaw
rebar- Steve Phone #: ###-####
BLD-Foundation12/20/201912/23/201912/23/2019PCANC
DetailsDave Hannah
sTEVE - REBAR INSPECTION Phone #: ###-####
Telephone call  12/5/2019 DONE
met GC form
Telephone call  12/4/2019 DONE
Received email from applicant designating Petra as the GC (see Docs). Informed him there would be a $35 fee and that Petra will have to submit a form 302
Meeting  12/3/2019 DONE
GC Petra Inc will be taking over this project, he was inform that a letter from the parcel owner is needed to change the name
Issue PAID IN FULL permit  9/13/2019 DONE
Print Occupancy Form  9/13/2019 DONE
Extend Review Timeline  2/22/2019 DONE
Final Approved 180 day extension per Adele. See documents
Expiration Notice2/12/20193/6/20192/12/2019 DONE
DetailsBrittany Hill
OVERRIDE  9/20/2018  
Permit Ready to Issue  9/20/2018 DONE
Need:
Revised cert of value from GC (after resubmittal where basement was removed from scope)-met 9-13-19 pdf
Verify HCD still GC (GC form from 5-31-18)-done parcel owner is the GC 9-13-19 CAN
Verify same RP - met 9-13-19 CAN
Plan assigned to (CJW)9/17/20189/17/20189/19/2018 PASS
DetailsCarl Westfall
Remove entire basement and exterior basement stair access - SCHROEDER OFFICE BUILDING
Routing - PLAN CHECK9/17/2018 9/19/2018 PASS
DetailsCarl Westfall
Basement deleted from the project. HVAC equipment installed in a closet on the 1st story. Drawings approved.
Routing - Design Review9/19/2018 9/19/2018 PASS
DetailsAndrea Tuning
Bike rack has been redlined.
Plan Reviewer's activity  9/19/2018 PASS
Completed the resubmittal review (called a plan mod).
Route to Impact Fee Review9/18/20189/21/20189/18/2018 PASS
DetailsEric Bilimoria
Plan resubmittals received  9/17/2018 DONE
(Turned in plan mod application, but permit has not been issued) remove entire basement and exterior basement stair access
CHANGE STATUS TO (REV)  9/17/2018 DONE
Plan mod app turned in before permit issued so resubmittals
Extend Review Timeline  9/5/2018 DONE
1st Approved 180 day extension per Adele. See documents
Telephone call  8/28/2018 DONE
sent email to Dennis, voicemail box full, informing permit will expire in 9 days and may send in a request for an extension
Expiration Notice8/17/20189/10/20188/17/2018 DONE
DetailsBrittany Hill
OVERRIDE  5/30/2018  
Plan assigned to (CJW)3/19/20183/19/20185/30/2018 PASS
DetailsCarl Westfall
* (3rd done) (Apr 20 - 25 days) (Mar 19 PI) (40 sheets) Schroeder Office Building New
Routing - Design Review5/29/2018 5/30/2018 PASS
DetailsAndrea Tuning
PLANS/APPL TAKEN TO FRONT DESK  5/30/2018 DONE
Permit Ready to Issue  5/30/2018 DONE
ALL MET
NEED
RP-met
GC FORM-met
REVISED VALUE-met
Routing - PUBLIC WORKS5/29/2018 5/29/2018 PASS
DetailsMorgan Webb
Brian needs to move his stamp to the most recent version.
Routing PW Drainage5/29/2018 5/29/2018 PASS
DetailsBrian Murphy
Brian, please move your stamp to the most recent version
Routing - PLAN CHECK5/26/2018 5/29/2018 PASS
DetailsCarl Westfall
Plan resubmittals received  5/26/2018 DONE
Received on a Saturday
Plan Reviewer's activity  5/17/2018 DONE
Uploaded a document and a revised sheet that was Emailed to me by the Architect
Routing PW Drainage5/17/2018 5/17/2018 PASS
DetailsBrian Murphy
Plan resubmittals requested  5/17/2018 DONE
Routing Off Site - STRUCTURAL5/7/2018 5/15/2018 PASS
DetailsCarl Westfall
Dave Haugland (AHJ)
Routing PW Drainage5/7/2018 5/15/2018 FAIL
Details
NEED STRUCTURAL LETTER/ AND SW ROOF CONVEYANCE
Routing PW Sewer Design5/7/2018 5/9/2018 PASS
DetailsDeAnn Brown
Note for Engineer. Existing service is likely only stubbed to property line.
Routing - Design Review5/7/2018 5/8/2018 FAIL
DetailsAndrea Tuning
The bicycle parking spaces shall be conveniently located, a minimum of 6-feet long and 2.5-feet wide, have an overhead clearance of 7-feet, provide a 4-foot wide aisle is required between rows of bicycle parking spaces and installed on a non-permeable surfaces and anchored to the ground.

Please move away from the building.
Routing - PLAN CHECK5/7/2018 5/8/2018 PASS
DetailsCarl Westfall
Pending structural
Plan resubmittals received  5/7/2018 DONE
Route to Impact Fee Review4/30/20185/3/20185/1/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Plan resubmittals requested  4/30/2018 DONE
1st review completed  4/30/2018 DONE
Routing - PLAN CHECK3/19/2018 4/30/2018 FAIL
DetailsCarl Westfall
Revised drawings required
Routing - FIRE3/19/20183/19/20184/18/2018 PASS
DetailsErika Akin
Attached comments to case
Routing Off Site - STRUCTURAL3/19/2018 4/2/2018 FAIL
DetailsCarl Westfall
Dave Haugland (AHJ)
Routing PW Street Lights3/19/2018 3/26/2018 PASS
DetailsTom Marshall
Routing - MECHANICAL3/19/2018 3/26/2018 PASS
DetailsTroy James
Routing PW Solid Waste3/19/2018 3/22/2018 PASS
DetailsEvan Carpenter
Approved for shared service with commercial subdivision.
Routing PW Sewer Design3/19/2018 3/22/2018 FAIL
DetailsDeAnn Brown
See redlines on sheet C2, grading and drainage plan, in eplanreview.
Routing PW Drainage3/19/2018 3/21/2018 FAIL
DetailsBrian Murphy
c-33, cross drainage, patio
Routing - PLUMBING3/19/2018 3/20/2018 PASS
DetailsBill VanDegrift
per plans and ISPC
Routing - PLANNING3/19/2018 3/20/2018  
DetailsSusan Riggs
No review required
Routing - Addressing3/19/2018 3/19/2018 PASS
DetailsDoug Chausow
Suite 110 and Suite 120
Routing - PUBLIC WORKS3/19/2018 3/19/2018 PASS
DetailsRachael Beierle
Routing - Erosion and Sediment3/19/2018 3/19/2018 PASS
DetailsMichael Zawacki
Valid RP needed before ground disturbance begin. Site prep and inspection required.
Intake Approval  3/19/2018 PASS
Routing - Design Review3/19/2018 3/19/2018 FAIL
DetailsAndrea Tuning
Intake Approval  3/14/2018 FAIL
DetailsJulie Romig
- Please confirm that the signature is the owner signature on Form 304 and Form 310 on the owner signature line; it appears to be the architect's signature. Upload revised documents with owner signature.
- Verification of Legal Lot or Parcel form signed by PDS Staff. Contact Todd Tucker at TTucker@cityofboise.org.
- Drainage System Operation & Maintenance Plan
- Revise Sheet A2.1 to include full construction type (Type VB). Also change Code Year from 2012 IBC to 2015 IBC. The City of Boise adopted the 2015 IBC beginning January 1 and project must comply with all currently adopted codes.
- Provide door hardware schedule. This can be generic. Hardware needs to be specified as lever style for accessibility and the locking function of each door needs to be specified (ie passage, office lock, entrance lock, panic hardware, etc).
Intake Approval  3/12/2018 FAIL
DetailsJulie Romig
Need 502 checklist and all required documents per checklist.
Application received  3/9/2018 DONE
Application submitted via PDS Online on Mar 9 2018 4:24PM