Permit Information
Permit NumberBLD18-00943
StatusFinaled
Name SLETTEN CONSTRUCTION
Site Address 2121 N COLE RD
Project NameFairmont Jr High Gymnasium
Customer Number 
ePlanReviewYes
Description
**(FAIRMONT JR HIGH – GYMNASIUM)** // 07/02/19 PLAN MOD TO LANDSCAPING AND GRADING. JAR // 05/29/18 PLAN MODIFICATION TO REMOVE BID ALTERNATES FROM DRAWING SET. JAR // Permit to construct a new 28,750 square foot gymnasium, locker rooms, and cafeteria with associated support areas including restrooms, kitchen associated office, storage, and mechanical rooms on the existing Fairmont Jr. High campus. Work also includes general site work. Special inspections required per attached Form 310. All work per the approved plans and notations. This building is fully fire sprinklered for area increase and is fully alarmed. JAR
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 11/8/201911/26/2019 DONE
mailed 12-2-19
First Notice 10/3/201910/29/2019 DONE
mailed 11-1
Permanent Occupancy  9/23/2019 DONE
BLD-Final9/18/20199/19/20199/19/2019APASS
DetailsTell Riley
Russ Phone #: ###-####//final is complete//landscaping is done//public works signed off//no sign off sheet onsite//
PubWorks Occupancy Approval9/19/20199/19/20199/19/2019 DONE
DetailsTiffany Lowery
BLD-Aging Inspection9/16/20199/16/20199/16/2019 PASS
DetailsTell Riley
working on landscaping
Temporary Occupancy8/12/201911/10/20198/12/2019 DONE
DetailsCandy A. Nichols
PubWorks Temp Occupancy Appr8/12/20198/12/20198/12/2019 DONE
DetailsMike Sheppard
BLD-Final7/15/20197/15/20197/15/2019PPART
DetailsTell Riley
Troy is here now. Phone #: ###-#### Inspection requested via web by Russell Valline//temp Occupancy ok//needs landscape complete and public works sign offs//
FIRE-Final Inspection7/15/20197/15/20197/15/2019PPASS
DetailsTroy Cobbley
Life safety is passed.. Phone #: ###-#### Inspection requested via web by Russell Valline
CHANGE STATUS TO (ISS)  7/12/2019 DONE
OVERRIDE  7/2/2019  
Plan assigned to (JAR)6/18/20196/18/20197/2/2019 DONE
DetailsJulie Romig
07/02 - Plan Mod 2 Fairmont High Gym
Routing - PLAN CHECK6/26/2019 7/2/2019 PASS
DetailsJulie Romig
Routing - PUBLIC WORKS6/26/2019 7/2/2019 PASS
DetailsMorgan Webb
Routing PW Street Lights6/26/2019 7/2/2019 PASS
DetailsTom Marshall
No review required per ePlanReview comments by TDM.
Permit Ready to Issue  7/2/2019 DONE
PLAN MOD
please do not re issue
Routing PW Drainage6/26/2019 6/27/2019 PASS
DetailsBrian Murphy
Telephone call  6/27/2019 DONE
Ed called me to see what fees were do for the plan mod-called him back- left message on his phone. We can't give him the amount because all the plan reviews have not be completed
Routing - FIRE6/26/20196/26/20196/26/2019 PASS
DetailsErika Akin
No impact to previous comments
Routing - Erosion and Sediment6/26/2019 6/26/2019 PASS
DetailsMichael Zawacki
Plan Mod Fairmont
Plan Modification Accepted  6/18/2019 DONE
2nd plan mod-Add light duty asphalt paving for basketball courts on East side of new cafereria building with 3 basketball standards and half-court striping. Modification to grading with added swale to East side of new basketball courts. Landscaping and irrigation are modified to accommodate new areas of paving.
BLD-Framing/Rough-in4/6/20194/8/20194/9/2019PPART
DetailsJim Sly
enter on west side of the Building please see Russ thank you. Phone #: ###-#### Inspection requested via web by Russell Valline
Framing....hard lid ceilings ....Locker rooms....plus......
BLD-Final3/21/20193/22/20193/22/2019APART
DetailsDave Hannah
come late morning we have fire in morning also thank you. Phone #: ###-#### Inspection requested via web by Russell Valline kitchen and lunch room area ok for temp occ
FIRE-Final Inspection3/21/20193/22/20193/22/2019APART
DetailsTroy Cobbley
Life safety passed for Phase 1.


Inspection requested via web by Russell Valline
BLD-Final3/20/20193/21/20193/21/2019PNR
DetailsJim Sly
Please come a little later Jim working on other inspections all day thanks Inspection requested via web by Russell Valline
Need to have Ron Hills Letter for Phased Occupancy on site for next inspection. Need Fire Temp. Occ. approval.
FIRE-Final Inspection3/20/20193/21/20193/21/2019PFAIL
DetailsTroy Cobbley
Need the project related fire alarm, fire sprinkler and hood suppression permits addressed. Need occupant load signs as discussed and fire dept access signage for the parking lot on the north side of the new building. Neeed determination of ADA requirements for the manual pull for the hood suppression system.

Please try to come early afternoon working on other inspections.

thanks s Phone #: ###-#### Inspection requested via web by Russell Valline
BLD-Ceiling Grid Inspection3/17/20193/18/20193/18/2019PPART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Russell Valline,, cloud in lunch room,, storage for kitchen, entry ok after trades are passed
FIRE-Conference3/17/20193/18/20193/18/2019ADONE
DetailsTroy Cobbley
I went over general life safety items with Russell. There were no small documents on site. Phone #: ###-#### Inspection requested via web by Russell Valline
BLD-Ceiling Grid Inspection3/4/20193/5/20193/5/2019APASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Russell Valline
BLD-Conference2/25/20192/26/20192/26/2019ADONE
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Russell Valline
FIRE-Conference2/25/20192/26/20192/26/2019ADONE
DetailsTroy Cobbley
Russel and I spoke about temp. occupancy requirements and exit paths. I deferred him to Ron Hill in project management.
Phone #: ###-#### Inspection requested via web by Russell Valline
BLD-Framing/Rough-in2/11/20192/12/20192/12/2019APASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Russell Valline kitchen/caff.cooller/closets/restarmms/hall/mez surround framing ok ceillings ok
BLD-Concrete9/13/20189/14/20189/14/2018PPASS
DetailsJim Storey
We are grouting our first lift tomorrow if you wanted to see. grout truck will be here at 2:00 All west will be here testing and inspecting. Phone #: ###-#### Inspection requested via web by Russell Valline
BLD-Foundation8/20/20188/21/20188/21/2018PPASS
DetailsJim Sly
All West is the Third party inspctor Phone #: ###-#### Inspection requested via web by Russell Valline
OK pending Allwest special inspections,tests and approvals.
FIRE-Final Inspection8/14/20188/17/20188/17/2018PPART
DetailsJim Page
Final life fire safety inspection for remodeled parking lot complete.

This is for the parking lot only Phone #: ###-#### Inspection requested via web by Russell Valline
BLD-Conference7/26/20187/27/20187/30/2018PDONE
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Russell Valline
BLD-Footing7/26/20187/27/20187/30/2018PDONE
DetailsJim Sly
These are interior footings we do have Allwest 3rd party inspection also Inspection requested via web by Russell Valline
OK pending Allwest special inspections, tests and approvals.
BLD-Foundation7/20/20187/23/20187/23/2018APASS
DetailsJim Sly
Jim just talk to you about this job and you explained as long Phone #: ###-#### Inspection requested via web by Russell Valline
OK pending Allwest special inspections tests and approvals.
BLD-Footing7/12/20187/13/20187/13/2018APASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Russell Valline
OK......pending Allwest special inspections, tests and approvals.
BLD-Footing7/11/20187/13/20187/12/2018ANR
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Russell Valline
Allwest will be special inspection.
OVERRIDE  5/29/2018  
Plan assigned to (JAR)5/10/20185/10/20185/29/2018 DONE
DetailsJulie Romig
*05/23 - Fairview Jr. High Plan Modification
Print Occupancy Form  5/29/2018 DONE
CHANGE STATUS TO (ISS)  5/29/2018 DONE
PLAN MOD
Routing Off Site - STRUCTURAL5/11/2018 5/29/2018 PASS
DetailsJulie Romig
Permit Ready to Issue  5/29/2018 DONE
Plan Mod Approved
DO NOT REISSUE
Routing - Erosion and Sediment5/11/2018 5/22/2018 PASS
DetailsMichael Zawacki
RP needs valid Con # or to be registered in class before construction activities.
Site prep inspection required.
Routing - ELECTRICAL5/11/2018 5/16/2018 PASS
DetailsDaryl DeGrange
Routing - PLUMBING5/11/2018 5/15/2018 PASS
DetailsBill VanDegrift
Routing PW Environmental5/14/2018 5/15/2018 PASS
DetailsRick Christenson
No additional issues.
Routing - FIRE5/11/20185/11/20185/14/2018 PASS
DetailsErika Akin
Routing - PLANNING5/14/2018 5/14/2018 PASS
DetailsCeline Acord
per CUP18-00004 approved by NCW
Routing - PUBLIC WORKS5/11/2018 5/14/2018 PASS
DetailsMorgan Webb
Routing - PLAN CHECK5/11/2018 5/14/2018 PASS
DetailsJulie Romig
Routing - MECHANICAL5/11/2018 5/14/2018 PASS
DetailsTroy James
Plan Modification Accepted  5/10/2018 DONE
plan mod workflow started to update plans
Issue PAID IN FULL permit  5/7/2018 DONE
Print Occupancy Form  5/7/2018 DONE
OVERRIDE  4/25/2018  
Plan assigned to (JAR)3/24/20183/24/20184/25/2018 DONE
DetailsJulie Romig
*1st Rev Comp - 2nd Rec'd 04/16 - 502 Fairmont Junior High
Routing Off Site - STRUCTURAL4/16/2018 4/25/2018 PASS
DetailsJulie Romig
2nd Review
PLANS/APPL TAKEN TO FRONT DESK  4/25/2018 DONE
Permit Ready to Issue  4/25/2018 DONE
met
Need
GC Form
Revised Cert of Value
RP
Routing - PLAN CHECK4/16/2018 4/20/2018 PASS
DetailsJulie Romig
2nd Review
Routing - FIRE4/16/20184/16/20184/18/2018 PASS
DetailsErika Akin
Attached revised comments to case
Routing - PLUMBING4/16/2018 4/18/2018 PASS
DetailsBill VanDegrift
per plans and ISPC
Routing PW Environmental4/16/2018 4/17/2018 PASS
DetailsTerry Alber
Kitchen plumbing rerouted per Pretreatment.
Route to Impact Fee Review4/5/20184/8/20184/5/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
1st review completed  4/5/2018 FAIL
DetailsJulie Romig
Routing Off Site - STRUCTURAL3/24/2018 4/5/2018 FAIL
DetailsJulie Romig
Routing - PLAN CHECK3/24/2018 4/4/2018 FAIL
DetailsJulie Romig
Plan Review Report emailed to Architect.
Routing - PLUMBING3/24/2018 3/30/2018 FAIL
DetailsBill VanDegrift
1) kitchen sink and dishwasher must be piped to the grease waste
2) vent required downstream of the interceptor
Routing - FIRE3/24/20183/24/20183/29/2018 FAIL
DetailsErika Akin
Attached comments and emailed architect
Routing PW Environmental3/26/2018 3/29/2018 FAIL
DetailsTerry Alber
ALL drains in kitchen, including dishwasher, need to reroute through grease interceptor. Please resubmit corrected plumbing plans.
Routing PW Drainage3/26/2018 3/28/2018 PASS
DetailsBrian Murphy
Routing - MECHANICAL3/24/2018 3/28/2018 PASS
DetailsTroy James
Routing - ELECTRICAL3/24/2018 3/28/2018 PASS
DetailsDaryl DeGrange
Routing PW Street Lights3/26/2018 3/27/2018 PASS
DetailsTom Marshall
Routing - PUBLIC WORKS3/24/2018 3/27/2018 PASS
DetailsRachael Beierle
Routing - Erosion and Sediment3/24/2018 3/26/2018 PASS
DetailsMichael Zawacki
RP needs valid Con # or to be registered in class before construction activities.
Site prep inspection required.
Routing PW Sewer Design3/26/2018 3/26/2018 PASS
DetailsDeAnn Brown
Project is located in West Boise Sewer District. Comply with West Boise Sewer District requirements. The Boise City sewer notes on the plan are an outdated version. Find the update here: https://publicworks.cityofboise.org/development-permits-or-requirements/sanitary-sewer-notes/
Routing PW Solid Waste3/26/2018 3/26/2018 PASS
DetailsEvan Carpenter
Routing - PLANNING3/24/2018 3/26/2018 PASS
DetailsNicolette Womack
Routing - Addressing3/24/2018 3/26/2018 PASS
DetailsDoug Chausow
Intake Approval  3/24/2018 PASS
Application received  3/16/2018 DONE
Application submitted via PDS Online on Mar 16 2018 1:11PM