Permit Information
Permit NumberBLD18-01550
StatusFinaled
Name STROTH GENERAL
Site Address 9095 S FEDERAL WAY Unit: 106
Project NameNikon & Future TI Suite #106
Customer NumberBLD18-01637
ePlanReviewYes
Description
**(NIKON – SUITE #106)** (2 BUILDING PERMITS UNDER BLD18-01550 IN EPLAN) Permit is to remodel an existing 4,655 sq. ft. tenant space by dividing it into two separate tenant spaces with a common breakroom/restroom’s. this tenant space is to be 1,214 sq. ft. and the remaining 1,954 sq. ft. is to be an unoccupied tenant space created under BLD18-01637. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal and relocation of select door/door frames, construction of select interior nonbearing wall to demise tenant common area, select wall infill and a new accessible restroom, select new door/door frames, electrical work, plumbing work and interior finishes in compliance with Ch. 8 of the current IBC. Note: This existing exiting door of suite #106 showed an exit rim device on the egress side with no key locking hardware, this is required so that it does not create a landlocked restroom with no exit. Door #d109 is also non-locking passage hardware allowing access to suite #106 hall 109 to exit the common area. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  1/4/2019 DONE
First Notice 12/8/201812/14/2018 DONE
mailed 12-17
Permanent Occupancy  11/28/2018 DONE
Permanent Occupancy  11/28/2018 DONE
BLD-Final11/27/201811/27/201811/27/2018PPASS
DetailsJim Storey
Rick Phone #: ###-####
FIRE-Final Inspection11/27/201811/27/201811/27/2018APASS
DetailsJim Page
Previously noted items for life fire safety inspection have been completed, final life fire safety inspection for area of work complete.
FIRE-Final Inspection11/26/201811/27/201811/27/2018APASS
DetailsJim Page
Final fire sprinkler inspection for area of work complete.

Rick Phone #: ###-####
FIRE-Final Inspection11/16/201811/19/201811/19/2018PFAIL
DetailsJim Page
Fire sprinkler permit is required for modifications to the fire sprinklers system, fire sprinklers are overspaced in area of work.



Rick Phone #: ###-####
BLD-Framing/Rough-in10/17/201810/18/201810/18/2018PPASS
DetailsJim Storey
Rick Phone #: ###-####
Issue PAID IN FULL permit  10/8/2018 DONE
Print Occupancy Form  10/8/2018 DONE
Route to Impact Fee Review5/31/20186/5/20185/31/2018 PASS
DetailsMatt Brookshier
Plan assigned to (JG)5/18/20185/18/20185/31/2018 PASS
DetailsJavier Guzman
1st rev comp, 5/18 L2 NIKON & FUTURE Suite #106 ePlan
Routing - PLAN CHECK5/26/2018 5/31/2018 PASS
DetailsJavier Guzman
Permit Ready to Issue  5/31/2018 DONE
Need- all met
GC Form
Revised Cert of Value-
DO NOT ISSUE WITHOUT BLD18-01637
PLANS/APPL TAKEN TO FRONT DESK  5/31/2018 DONE
Routing - Addressing5/26/2018 5/29/2018 PASS
DetailsDoug Chausow
Please sign off in tidemark BLD18-01637
1st review completed  5/21/2018 DONE
DetailsJavier Guzman
Routing - PLAN CHECK5/9/2018 5/21/2018 FAIL
DetailsJavier Guzman
Routing - PUBLIC WORKS5/9/2018 5/9/2018 PASS
DetailsRachael Beierle
Intake Approval  5/5/2018 PASS
Application received  5/2/2018 DONE
Application submitted via PDS Online on May 2 2018 11:06AM