Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD18-01737
StatusFinaled
Name HC COMPANY INC
Site Address 12601 W EXPLORER DR Unit: 250
Project NameHewlette Packard Enterprise
Customer Number 
ePlanReviewYes
Description
(HEWLETT PACKARD ENTERPRISE – SUITE #250) This building is fire sprinklered for building area increase and 1-hour substitution. Permit is to remodel an existing 9,064 sq. ft. business space on the second floor within the existing building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, removal of select millwork, removal of select suspended acoustic ceiling, removal of select light fixtures, select removal and replacement to an exterior window, construction of interior non-bearing walls to create (3) conference rooms, a break area, (2) team/conference rooms, (2) phone rooms, a lobby, a focus room, a neighborhood area and open office areas, select new door/door frames, select new interior storefront windows, rated plywood on walls of the IDF room #211, select new suspended acoustic ceiling, select new light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice 9/22/20189/12/2018 DONE
done
Print Statement  9/12/2018 DONE
Print Occupancy Form  9/12/2018 DONE
Permanent Occupancy  9/12/2018 DONE
BLD-Final9/11/20189/11/20189/11/2018PPASS
DetailsMike Jordan
Phone #: 2085904252 >> Inspection requested via mobile web by Jon craft. Ok for prem occ.
FIRE-Final Inspection9/11/20189/11/20189/11/2018PPASS
DetailsMike Jordan
Phone #: 2085904252 >> Inspection requested via mobile web by Jon craft. Life safety ok for final. The project related fire sprinkler has been finaled by Forest France and fire alarm by Lee Merideth.
BLD-Ceiling Grid Inspection8/20/20188/20/20188/20/2018APART
DetailsJim Sly
Please inspect north and south work space and conference rooms. Please omit hallway grid. Will call back for future inspection Phone #: ###-#### Inspection requested via web by Jonathan Craft
BLD-Framing/Rough-in7/3/20187/3/20187/3/2018APASS
DetailsMike Jordan
As early as possible Phone #: 2085904252 >> Inspection requested via mobile web by Jon craft. Interior steel stud framed walls ok. Soffits ok, pending electrical and fire sprinkler rough in inspections.
Issue PAID IN FULL permit  6/19/2018 DONE
Print Occupancy Form  6/19/2018 DONE
Permit Ready to Issue  6/18/2018 DONE
DetailsChristina Prado
Need - met
GC Form
(revised cert of value if HC company is not the GC)
Plan assigned to (JG)5/22/20185/22/20186/16/2018 PASS
DetailsJavier Guzman
1st rev comp, 6/04 L2 HPE Brighton TI ePlan
Routing - PLAN CHECK6/14/2018 6/16/2018 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  6/16/2018 DONE
Route to Impact Fee Review6/7/20186/10/20186/8/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
1st review completed  6/7/2018 FAIL
DetailsJavier Guzman
Routing - PLAN CHECK5/22/2018 6/7/2018 FAIL
DetailsJavier Guzman
Routing - Addressing5/22/2018 6/6/2018 PASS
DetailsDoug Chausow
Passed in ePlan by PW Addressing Doug Chausow
Routing - MECHANICAL5/22/2018 5/24/2018 PASS
DetailsChad Schwendiman
Routing - PLUMBING5/22/2018 5/24/2018 PASS
DetailsBill VanDegrift
1) additional cross connection protection may be required at the coffee and ice machines
2) ceiling is a plenum
Routing - PUBLIC WORKS5/22/2018 5/22/2018 PASS
DetailsMorgan Webb
Routing - Design Review5/22/2018 5/22/2018 PASS
DetailsKatelyn Menuge
Glass change okay.
Intake Approval  5/22/2018 PASS
DetailsJavier Guzman
Intake Approval  5/17/2018 FAIL
DetailsMichael Hanson
This permit has failed prescreen due to the following:
1. Missing 518 form completed and signed.
2. Missing existing / demo plan.
3. Missing lighting compliance COMcheck completed and signed.
Application received  5/16/2018 DONE
Application submitted via PDS Online on May 16 2018 12:15PM