BLD-Final | 11/5/2018 | 11/6/2018 | 11/6/2018 | P | PASS |
Jim Storey
|
|
|
Call before heading to site Phone #: ###-#### Inspection requested via web by Curtis Bodenbender
|
DOC - Permit Finaled | 11/6/2018 | 11/6/2018 | 11/6/2018 | P | PASS |
Jim Storey
|
|
|
|
BLD-Wall cover | 9/12/2018 | 9/13/2018 | 9/13/2018 | A | PASS |
Dave Hannah
|
|
|
Phone #: 2084120436 >> Inspection requested via mobile web by Curtis
|
BLD-Energy code compliance | 9/3/2018 | 9/4/2018 | 9/4/2018 | A | PASS |
Jim Storey
|
|
|
Phone #: 2084120436 >> Inspection requested via mobile web by Curtis
|
BLD-Energy code compliance | 8/28/2018 | 8/29/2018 | 8/29/2018 | P | PART |
Jim Storey
|
|
|
Phone #: 208410436 >> Inspection requested via mobile web by Curtis air seal only
|
BLD-Framing/Rough-in | 8/28/2018 | 8/29/2018 | 8/29/2018 | P | PASS |
Jim Storey
|
|
|
Phone #: 208410436 >> Inspection requested via mobile web by Curtis
|
BLD-Wall Bracing | 8/23/2018 | 8/24/2018 | 8/24/2018 | A | NR |
Jim Storey
|
|
|
Needing a sheer wall inspection. Phone #: ###-#### Inspection requested via web by Curtis Bodenbender
|
BLD-Foundation | 7/17/2018 | 7/17/2018 | 7/17/2018 | P | PASS |
Jim Storey
|
|
|
Concrete at 2pm- Brandon Phone #: ###-#### mono placement ft and wall ok rebar ok
|
Issue PAID IN FULL permit | | | 7/9/2018 | | DONE |
|
|
|
|
(F) Reprint permit | | | 7/9/2018 | | DONE |
|
|
|
|
OVERRIDE | | | 7/5/2018 | | |
|
|
|
|
Plan assigned to (JAB) Josh | 5/23/2018 | 5/23/2018 | 7/5/2018 | | PASS |
Josh Bogle
|
|
|
1st done - addition, lacking several details
|
Routing - PLAN CHECK | 7/5/2018 | | 7/5/2018 | | PASS |
Josh Bogle
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/5/2018 | | DONE |
Josh Bogle
|
|
|
ESC yes - Energy Yes - 2hrs (five Plan Checks total)
|
Telephone call | | | 7/5/2018 | | DONE |
|
|
|
Left voicemail and emailed Curtis to confirm the acres disturbed is correct and if not to let us know what the correct amount is. Gave Rita's email incase the acres disturbed is incorrect.
|
Permit Ready to Issue | | | 7/5/2018 | | DONE |
|
|
|
Need
RP
(see telephone call activity)
|
Routing - PLAN CHECK | 6/29/2018 | | 6/29/2018 | | FAIL |
Josh Bogle
|
|
|
footings are based on 2,000psf
|
Routing - PLAN CHECK | 6/22/2018 | | 6/22/2018 | | FAIL |
Josh Bogle
|
|
|
|
Routing Walk-In (BLD) | 6/7/2018 | 6/7/2018 | 6/7/2018 | P | FAIL |
Josh Bogle
|
|
|
|
Routing - PLAN CHECK | 6/7/2018 | | 6/7/2018 | | FAIL |
Josh Bogle
|
|
|
|
Routing - PLAN CHECK | 5/23/2018 | | 5/30/2018 | | FAIL |
Josh Bogle
|
|
|
lacking several details
|
1st review completed | | | 5/30/2018 | | DONE |
Josh Bogle
|
|
|
|
Routing - PLANNING | 5/23/2018 | | 5/24/2018 | | PASS |
Sue Cummings
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 5/23/2018 | | DONE |
|
|
|
|
Intake Approval | | | 5/23/2018 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 5/23/2018 | | DONE |
|
|
|
|
Intake Approval | | | 5/22/2018 | | FAIL |
|
|
|
Need to provide all structural details (framing, sheathing, etc.) and stair section. See checklist items
|
Intake Approval | | | 5/21/2018 | | FAIL |
|
|
|
1.Please upload plans in the correct orientation (Landscape vs. Horizontal)
2. On Rear Elevations, Front Elevations and Elevations B2.0, can't read the details.
|
Application received | | | 5/17/2018 | | DONE |
|
|
|
Application submitted via PDS Online on May 17 2018 2:59PM
|