Permit Information
Permit NumberBLD18-01882
StatusFinaled
Name BURTON CONSTRUCTION INC
Site Address 5103 W BETHEL ST
Project NameBurton Const Office Shell Bldg
Customer NumberBLD18-03045
ePlanReviewYes
Description
(BURTON CONSTRUCTION SHELL) **Permit for the construction of a new 6,300 sq. ft. pre-engineered shell storage building and related site improvements. Tenant improvement for Suite 110 under separate permit BLD18-03045. Scope of work includes: construction of slab on grade concrete foundation, pre-engineered shell with insulation, interior non-bearing tenant demising walls, electrical, mechanical, plumbing, and interior finishes to be in compliance with Ch. 8 of the 2015 IBC. All work shall comply with the approved plans, DRH16-00233 and all applicable codes. This building is NOT Fire Sprinklered. Note: Special Inspections Required, see two attached Form 310s. Note: complies with ANSI/ASHRAE 90.1. **JAR**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  1/28/2020 DONE
Inspection Record Card- Bld  1/28/2020 DONE
BLD-Final1/27/20201/27/20201/27/2020PPASS
DetailsTell Riley
need passing final inspection to close out permit please//final was complete pending other required inspections//
First Notice 1/27/20201/17/2020 DONE
Final value for BLD18-01882 and BLD18-03045 done together. Credit for value pulled on this permit applied toward final value on BLD18-03045.
Telephone call  1/17/2020 DONE
Called and left vm for Paul w/Burton Construction for clarification on final cert of value. //call back 1/23 excavator and landscaping plumbing permits not included in plumbing value..LEG
Letter of compliance/Occupancy  1/13/2020 DONE
Zoning Approval1/7/20201/7/20201/8/2020 PASS
DetailsKayCee Babb
Per DRH17-00353 and DRH19-00555
Zoning Approval12/10/201912/10/201912/10/2019 FAIL
DetailsKayCee Babb
Landscaping and fencing on site does not comply with DRH17-00353. A modification application is required to proceed.
PubWorks Occupancy Approval12/9/201912/9/201912/9/2019 DONE
DetailsTiffany Lowery
BLD-Final12/5/201912/6/201912/6/2019PPEND
DetailsTell Riley
Paul Phone #: ###-####//special inspection report provided for structural bolting, compaction, and concrete//final on shell ok pending zoning final and ACHD signature//
BLD-Final11/25/201911/26/201911/26/2019PNR
DetailsTell Riley
Michael Phone #: ###-####//need final special inspections report//
FIRE-Final Inspection11/25/201911/26/201911/26/2019APASS
DetailsTroy Cobbley
Life safety passed.

Michael Phone #: ###-####
BLD-Foundation12/21/201812/26/201812/26/2018APART
DetailsTony Young
pour at 10 // zack Phone #: ###-####,, special inspector on site also,, work in progress
BLD-Footing12/7/201812/10/201812/10/2018APASS
DetailsJim Sly
Zack Phone #: ###-####
OK pending MTI special inspection, tests and approvals.
Issue PAID IN FULL permit  10/23/2018 DONE
Inspection Record Card- Bld  10/23/2018 DONE
Route to Impact Fee Review10/17/201810/22/201810/17/2018 PASS
DetailsEric Bilimoria
OVERRIDE  9/4/2018  
Plan assigned to (JAR)6/13/20186/13/20189/4/2018 DONE
DetailsJulie Romig
08/27 - 2nd Rev - 1st Rev Comp - 502 Burton Construction New
Routing Off Site - STRUCTURAL8/21/2018 9/4/2018 PASS
DetailsJulie Romig
PLANS/APPL TAKEN TO FRONT DESK  9/4/2018 DONE
Permit Ready to Issue  9/4/2018 DONE
Need- all met
RP-met
ACDH-met
GC Form-met
Revised Cert of Value-MET
Routing - FIRE8/24/20188/24/20188/24/2018 PASS
DetailsErika Akin
Attached comments to case
Routing PW Solid Waste8/21/2018 8/22/2018 PASS
DetailsEvan Carpenter
Routing PW Sewer Design8/21/2018 8/22/2018 PASS
DetailsDeAnn Brown
Routing - Design Review8/21/2018 8/22/2018 PASS
DetailsAndrea Tuning
Routing - PLAN CHECK8/21/2018 8/22/2018 PASS
DetailsJulie Romig
Routing - PLANNING6/13/2018 8/22/2018 PASS
DetailsSusan Riggs
CVA17-00073
Routing - PLAN CHECK6/13/2018 8/3/2018 FAIL
DetailsJulie Romig
1st review completed  8/3/2018 DONE
Routing - FIRE6/13/20186/13/20187/24/2018 FAIL
DetailsErika Akin
Attached comments to case and emailed architect
Routing Off Site - STRUCTURAL6/13/2018 6/27/2018 FAIL
DetailsJulie Romig
Routing - MECHANICAL6/13/2018 6/19/2018 PASS
DetailsTroy James
Routing PW Environmental6/13/2018 6/15/2018 PASS
DetailsRick Christenson
Routing PW Drainage6/13/2018 6/15/2018 PASS
DetailsBrian Murphy
Routing PW Solid Waste6/13/2018 6/14/2018 FAIL
DetailsEvan Carpenter
The solid waste enclosure must have at least 12 feet of unobstructed clearance between gate posts (measured from the innermost points).
Routing PW Sewer Design6/13/2018 6/13/2018 FAIL
DetailsDeAnn Brown
Please add sewer tap language shown in changemarks on sheet C2.0.
Routing PW Street Lights6/13/2018 6/13/2018 PASS
DetailsTom Marshall
Routing - Addressing6/13/2018 6/13/2018 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS6/13/2018 6/13/2018 PASS
DetailsRachael Beierle
Routing - Erosion and Sediment6/13/2018 6/13/2018 PASS
DetailsMichael Zawacki
Valid RP needed prior to ground disturbing activities.
Routing - PLUMBING6/13/2018 6/13/2018 PASS
DetailsBill VanDegrift
per plans and ISPC
Routing - Design Review6/13/2018 6/13/2018 FAIL
DetailsAndrea Tuning
Install a wianscot on the front elevation.

Install a 5-foot wide pedestrian pathway that extends from the front of the building to Bethel Street.

Provide 2 bicycle parking spaces to be located within 50-feet of the buildings main entrance. The spaces shall be on improved non-permeable surfaces, anchored to the ground, a minimum of 6-feet long and 2.5-feet wide with 4-foot wide aisles between rows of bicycle parking spaces or nearby walls.

Install 4 Imperial Honey Locust trees along Bethel Street.

Construct terminal landscape planters at the terminus of each parking row. Each planter shall be 8-feet in width (measured inside of curb to inside of curb) and contain one Class II tree with low growing shrubs or ground cover.

Install a mixture of deciduous and evergreen trees, shrubs, or other vegetative groundcover that will create a visual barrier that provides a minimum of 60 percent of a barrier within five years of planting in order to adequately screen the residential property to the east.

Install slats within teh chain link fence.
Intake Approval  6/8/2018 PASS
Plans ACCEPTED BY PLAN TECH  6/8/2018 DONE
DetailsChristina Prado
Recd Pcfee & Taken To Pln CK  6/8/2018 DONE
DetailsChristina Prado
Intake Approval  6/7/2018 FAIL
DetailsJavier Guzman
Please provide and upload the following:
1. Please upload form #310 – Statement of Special Inspections. all the applicable areas of the #310 sheets must filled out completely with the cover sheet stamped, signed and dated by the Idaho licensed engineer and uploaded, form #310 can be found at our website at https://pds.cityofboise.org/media/104147/final310_special_inspections.pdf
2. All (29) of the R&M structural plan sheets are required to be on a minimum 18” x 24” plan sheets (currently they are all on 11” x 17” plan sheets)
Application received  5/29/2018 DONE
Application submitted via PDS Online on May 29 2018 4:30PM