BLD-Final | 11/29/2018 | 11/29/2018 | 11/30/2018 | P | PASS |
Jim Storey
|
|
|
Garage code: 0805 Phone #: ###-#### Inspection requested via web by Elena Stephens
|
DOC - Permit Finaled | 11/30/2018 | 11/30/2018 | 11/30/2018 | P | PASS |
Jim Storey
|
|
|
|
BLD-Blower Door Test Results | 11/30/2018 | 11/30/2018 | 11/30/2018 | A | DONE |
Jim Storey
|
|
|
Garage code: 0805 Phone #: ###-#### Inspection requested via web by Elena Stephens 4.6
|
BLD-Energy code compliance | 9/13/2018 | 9/13/2018 | 9/13/2018 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Framing/Rough-in | 9/11/2018 | 9/11/2018 | 9/11/2018 | P | PASS |
Jim Storey
|
|
|
Inspection requested via web by Marc Foote// 2nd floor back deck canlights not done w/gyp for soffit insp.
|
BLD-Framing/Rough-in | 9/6/2018 | 9/7/2018 | 9/7/2018 | P | CANC |
Jim Storey
|
|
|
>> Inspection requested via web by Marc Foote Inspection cancelled from web by: Marc Foote
|
BLD-Wall Bracing | 8/22/2018 | 8/22/2018 | 8/22/2018 | P | PASS |
Jim Storey
|
|
|
Inspection requested via web by Marc Foote
|
BLD-Footing | 7/17/2018 | 7/18/2018 | 7/18/2018 | A | PASS |
Jim Storey
|
|
|
Jared Phone #: ###-####
|
Issue PAID IN FULL permit | | | 7/12/2018 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 7/12/2018 | | DONE |
|
|
|
|
OVERRIDE | | | 7/11/2018 | | |
|
|
|
|
Plan assigned to (RDP) | 6/25/2018 | 6/25/2018 | 7/11/2018 | | DONE |
Rob Patrick
|
|
|
7/6 sfd L1 eplan...7/6 Failed; Corrections Required
|
Routing - PLANNING | 7/11/2018 | | 7/11/2018 | | PASS |
Sue Cummings
|
|
|
Letter of satisfaction received. OK now
|
Routing - PLAN CHECK | 7/11/2018 | | 7/11/2018 | | PASS |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/11/2018 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 7/11/2018 | | DONE |
|
|
|
|
1st review completed | | | 7/6/2018 | | FAIL |
Rob Patrick
|
|
|
Correction required
|
Routing - PLAN CHECK | 6/25/2018 | | 7/6/2018 | | FAIL |
Rob Patrick
|
|
|
Corrections Required
|
Routing - MECHANICAL | 6/25/2018 | | 6/29/2018 | | PASS |
Troy James
|
|
|
|
Route to Impact Fee Review | 6/25/2018 | 6/28/2018 | 6/26/2018 | | PASS |
Eric Bilimoria
|
|
|
Initial residential review of new SFD permits requested for now.
|
Plans ACCEPTED BY PLAN TECH | | | 6/25/2018 | | DONE |
|
|
|
|
Intake Approval | | | 6/25/2018 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 6/25/2018 | | DONE |
|
|
|
|
Routing - Addressing | 6/25/2018 | | 6/25/2018 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 6/25/2018 | | 6/25/2018 | | PASS |
Morgan Webb
|
|
|
|
Application received | | | 6/22/2018 | | DONE |
|
|
|
Application submitted via PDS Online on Jun 22 2018 11:09AM
|
Routing - PLANNING | 6/25/2018 | | | | FAIL |
|
|
|
The letter of satisfaction has NOT been signed for the subdivision
|