Permit Information
Permit NumberBLD18-02407
StatusFinaled
Name TITAN TECHNOLOGIES INC
Site Address 1023 S CURTIS RD
Project NameBoise Love Inc Storage
Customer Number 
ePlanReviewYes
Description
(BOISE LOVE INC.) This building does not have a fire sprinkler system. Special inspections for concrete required per attached Form 310. To construct a new free standing 30'x65' storage building that totals 1,950 sq. ft. Work is to include concrete piers & footings, concrete foundation stem walls, concrete slab on grade, pre-engineered metal building frame, metal wall panels, metal roof panels, three sectional overhead doors, and a double side-hinged swinging exit door. This building will not be conditioned or insulated. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. This building is only approved for occupancy and use during the daytime since no mean of egress illumination is being provided. See letter submitted with this case by the applicant stating the storage building will only be accessed in day-light hours. Racking that exceeds 8 ft. in height requires a separate Building Permit. **JHB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice7/27/20207/27/20208/11/2020 DONE
DetailsMike Jordan
MAILED 8-14-2020
BLD-Final7/24/20207/27/20207/27/2020APASS
DetailsMike Jordan
SCREENED // Kimbra Phone #: ###-####
DOC - Permit Finaled7/27/20207/27/20207/27/2020PPASS
DetailsMike Jordan
FIRE-Final Inspection7/23/20207/23/20207/23/2020PPASS
DetailsTroy Cobbley
Life safety passed.

call for access- Kimbra *screened* Phone #: ###-####
Zoning Approval7/23/20207/23/20207/23/2020 DONE
DetailsCeline Acord
FIRE-Conference7/21/20207/21/20207/21/2020PDONE
DetailsTroy Cobbley
We went over life safety requirements.

Kimbra ###-####
BLD-Final7/17/20207/17/20207/17/2020PCANC
DetailsMike Jordan
Screened-Cliff Phone #: ###-####.
PubWorks Occupancy Approval7/17/20207/17/20207/17/2020 DONE
DetailsTiffany Lowery
BLD-Conference12/2/201912/2/201912/2/2019PPASS
DetailsMike Jordan
aDAM Phone #: ###-####
BLD-Wall Bracing11/27/201911/27/201911/27/2019PPASS
DetailsMike Jordan
FIRE WALL // Adam Phone #: ###-####
BLD-Conference11/22/201911/22/201911/22/2019PDONE
DetailsMike Jordan
Adam Phone #: ###-####
BLD-Framing/Rough-in10/14/201910/15/201910/15/2019PPASS
DetailsMike Jordan
Kimbra Phone #: ###-####. Observed install of 3 1/2 inch all thread rods epoxied into concrete footing. All holes were blown clean and brushed. All work was done per the engineers RFI and manufactures instructions.
BLD-Conference9/18/20199/19/20199/19/2019ACANC
DetailsMike Jordan
BLD-Conference9/17/20199/18/20199/18/2019PDONE
DetailsMike Jordan
Call ahead 20 minutes - foundation poured in wrong spot - need advice // Kimbra Phone #: ###-####
BLD-Concrete8/20/20198/22/20198/22/2019PPASS
DetailsMike Jordan
after 2pm // Doug Phone #: ###-####. Welded wire mesh for slab on grade ok.
BLD-Concrete8/5/20198/6/20198/6/2019PPASS
DetailsMike Jordan
rebar- after 2:30pm please- Doug Phone #: ###-####. Ties replaced. ok.
BLD-Foundation8/6/20198/6/20198/6/2019PPASS
DetailsMike Jordan
rebar- after 2:30pm please- Doug Phone #: ###-####
BLD-Footing7/19/20197/23/20197/23/2019PCANC
DetailsMike Jordan
rebar - after 2 pm // Doug Phone #: ###-####
BLD-Foundation7/23/20197/23/20197/23/2019PFAIL
DetailsMike Jordan
rebar - after 2 pm // Doug Phone #: ###-####. Hairpins not installed around anchor bolts. #3 ties do not conform to ACI standards. Ties are not continous and missing hooks. Contractor noted that this rebar was donated. Noted to contractor that the ties still need to meet ACI.
BLD-Foundation7/10/20197/10/20197/10/2019PPASS
DetailsMike Jordan
Doug - after 2pm Phone #: ###-####. Footings ok. City approved plans on site. Noted that building pad appears to be built up 3/4 inch road mix. Footings appear to be on undisturb native soils. Called and have left message with owner, Micheal Moore, to call me back to discuss pad and if compaction testing was completed.
BLD-Concrete7/1/20197/3/20197/3/2019PNR
DetailsMike Jordan
late afternoon - rebar // Doug Phone #: ###-####. Needs to provide the city set of approved plans. Also noted to concrete contractor that special inspection is required.
Issue PAID IN FULL permit  3/25/2019 DONE
Print Occupancy Form  3/25/2019 DONE
Print Occupancy Form  3/25/2019 DONE
Telephone call  3/25/2019 DONE
emailed clcox2211@msn.com permits to be signed
Extend Review Timeline  1/3/2019 DONE
1st approved 180 day extension per adele. see documents
Meeting  12/28/2018 DONE
sent in extension request 12-28-18
Telephone call  12/27/2018 DONE
Spoke with Michael informing him that this permit is going to expire in 6 days. stated he is welcome to send in a request if not ready to pick the permit up.
Telephone call  12/24/2018 DONE
Left a message for Michael informing tired to send a letter about expiring permit and just needed to get an updated address from him
Expiration Notice12/11/20181/3/201912/11/2018 DONE
DetailsBrittany Hill
OVERRIDE  11/14/2018  
Plan assigned to (JHB)8/23/20188/23/201811/14/2018 PASS
DetailsJoe Bruce
*(2nd Rev Comp) 10/01 (502) - Love Inc Storage (Struc)
Routing Off Site - STRUCTURAL11/13/2018 11/14/2018 PASS
DetailsJoe Bruce
PLANS/APPL TAKEN TO FRONT DESK  11/14/2018 DONE
Permit Ready to Issue  11/14/2018 DONE
ALL MET email: clcox2211@msn.com

NEED
GC FORM
REVISED VALUE

MET
ACHD
RP
Plan resubmittals received  11/9/2018 DONE
DetailsJoe Bruce
Received revised structural calculations with stamp/signature. **JHB**
Routing PW Drainage10/31/2018 10/31/2018 PASS
DetailsBrian Murphy
Routing - PLAN CHECK10/24/2018 10/29/2018 PASS
DetailsJoe Bruce
Plan resubmittals requested  10/29/2018 FAIL
DetailsJoe Bruce
Emailed applicant regarding information need from structural plan review. **JHB**
Routing Off Site - STRUCTURAL10/24/2018 10/25/2018 FAIL
DetailsJoe Bruce
Chris Holladay - AHJ Engineers
Plan resubmittals received  10/24/2018 DONE
DetailsJoe Bruce
Route to Impact Fee Review10/3/201810/6/201810/4/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE8/23/20188/23/201810/3/2018 PASS
DetailsErika Akin
Attached comments to case
1st review completed  10/3/2018 FAIL
DetailsJoe Bruce
Plan resubmittals requested  10/3/2018 DONE
DetailsJoe Bruce
Emailed Plan Review Report to applicant on 10/01. **JHB**
Routing Off Site - STRUCTURAL8/23/2018 10/1/2018 FAIL
DetailsJoe Bruce
Chris Holladay - AHJ Engineers (Corrections Required)
Routing - PLAN CHECK8/23/2018 10/1/2018 FAIL
DetailsJoe Bruce
Emailed architect plan review report on 10/01.
Routing - Erosion and Sediment8/23/2018 8/27/2018 PASS
DetailsMichael Zawacki
RP needed. SWPPP narative states prime hasn't been selected at time of writing.
Routing - Addressing8/23/2018 8/24/2018 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS8/23/2018 8/24/2018 PASS
DetailsRachael Beierle
Routing PW Drainage8/24/2018 8/24/2018 FAIL
DetailsBrian Murphy
NEED DRAINAGE LETTERE REPORT
Plans ACCEPTED BY PLAN TECH  8/23/2018 DONE
Recd Pcfee & Taken To Pln CK  8/23/2018 DONE
Routing - PLANNING8/23/2018 8/23/2018 PASS
DetailsCeline Acord
per CUP18-00007
Intake Approval  8/21/2018 PASS
Intake Approval  8/10/2018 FAIL
Intake Approval  7/26/2018 FAIL
Intake Approval  7/19/2018 FAIL
Application received  7/6/2018 DONE
Application submitted via PDS Online on Jul 6 2018 10:53AM
Second Notice 8/21/2020