Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD18-02488
StatusFinaled
Name RAISTRICK CONSTRUCTION
Site Address 9196 W EMERALD ST Unit: 125
Project NameVanilla Suite 125
Customer NumberBLD18-02517
ePlanReviewYes
Description
**(VANILLA – SUITE #125)** (2 BUILDING PERMITS UNDER BLD18-02488 IN EPLAN) NO OCCUPANCY ALLOWED UNDER THIS PERMIT. TENANT SHALL APPLY FOR CERTIFICATE OF OCCUPANCY PRIOR TO OCCUPYING THE SPACE. Permit is to remodel an existing 3,815 sq. ft. tenant space by dividing it into two separate tenant spaces, this vacant tenant space is to be 2,249 sq. ft. and the remaining vacant tenant space is to be 1,566 sq. ft. created under BLD18-02517. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select wall for new interior window opening, removal of select door/door frame, construction of select interior nonbearing wall to demise tenant spaces, new wall to create a break room, new Hi/Lo drinking fountain, new plumbing fixture, relocation of existing service sink, new vertical grab bars at existing accessible restrooms, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 11/17/201812/14/2018 DONE
mailed 12-17
First Notice10/12/201810/12/201811/7/2018 DONE
DetailsMike Jordan
mailed 11-12
BLD-Final10/11/201810/12/201810/12/2018APASS
DetailsMike Jordan
Tom Phone #: ###-####
DOC - Permit Finaled10/12/201810/12/201810/12/2018PPASS
DetailsMike Jordan
FIRE-Final Inspection10/11/201810/11/201810/11/2018PPASS
DetailsJim Page
Final life fire safety inspection for area of work complete.

Tom Phone #: ###-####
BLD-Framing/Rough-in9/4/20189/7/20189/7/2018APASS
DetailsMike Jordan
Tom Phone #: ###-####
Issue PAID IN FULL permit  7/30/2018 DONE
Inspection Record Card- Bld  7/30/2018 DONE
Plan assigned to (JG)7/18/20187/18/20187/26/2018 PASS
DetailsJavier Guzman
1st rev comp, 7/24 L1 Pinnacle Sq. Vanilla Suite 125 ePlan
Routing - PLAN CHECK7/26/2018 7/26/2018 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  7/26/2018 DONE
Permit Ready to Issue  7/26/2018 DONE
NEED
GC FORM
REVISED VALUE
Routing - PLAN CHECK7/18/2018 7/25/2018 FAIL
DetailsJavier Guzman
1st review completed  7/25/2018 FAIL
DetailsJavier Guzman
Routing - Addressing7/18/2018 7/18/2018 PASS
DetailsDoug Chausow
Please sign off in Tidemark BLD18-02517
Routing - PUBLIC WORKS7/18/2018 7/18/2018 PASS
DetailsMorgan Webb
Please sign off in Tidemark BLD18-02517
Intake Approval  7/18/2018 PASS
DetailsJavier Guzman
Application received  7/12/2018 DONE
Application submitted via PDS Online on Jul 12 2018 2:25PM