Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD18-02736
StatusFinaled
Name BLACKROCK HOMES LLC
Site Address 2524 E WARM SPRINGS AVE
Project NameParker B
Customer Number 
ePlanReviewYes
Description
WUI FOOTHILLS, ZONE "A" REQUIREMENTS, CLASS "A" ROOF REQUIRED. Permit for the construction of a new 2542 sq. ft., two story (first story 1909 sq. ft., second story 633 sq. ft.) single family dwelling with 3 bedrooms, 3 bathrooms, approximately 171 sq. ft. of covered patio/porch and a 822 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. ***BJM*** Project has been removed from Hillside requirements. A subgrade inspection is required due to conditions of approval for the subdivision.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/26/20192/28/20192/28/2019APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Clint Wall
DOC - Permit Finaled2/28/20192/28/20192/28/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results2/26/20192/28/20192/28/2019ADONE
DetailsBrandon Shaw
ACH50- 4.75
BLD-Energy code compliance12/17/201812/17/201812/17/2018PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Clint Wall
BLD-Framing/Rough-in12/17/201812/17/201812/17/2018PPASS
DetailsDave Hannah
BLD-Framing/Rough-in12/11/201812/13/201812/13/2018AFAIL
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Clint Wall c/n on site do not insulate
Plan Modification Accepted  11/30/2018 DONE
New manual j report
Routing - MECHANICAL11/30/2018 11/30/2018 PASS
DetailsTroy James
resubmitted manual j report
BLD-Wall Bracing11/29/201811/29/201811/29/2018PPASS
DetailsDave Hannah
Eber Phone #: ###-####
BLD-Wall Bracing11/28/201811/28/201811/29/2018PNR
DetailsDave Hannah
SHEAR // EVER Phone #: ###-#### missing two hold downs and needs to add stapels to panels
BLD-Foundation9/28/201810/1/201810/1/2018PPASS
DetailsDave Hannah
WALL // Jose Phone #: ###-####
BLD-Footing9/28/20189/28/20189/28/2018PPASS
DetailsDave Hannah
Jose Phone #: ###-####
PubWorks Subgrade Approval9/27/20189/27/20189/27/2018 DONE
DetailsJason C. Taylor
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
OVERRIDE  9/18/2018  
Plan assigned to (BJM)9/12/20189/12/20189/18/2018 DONE
DetailsBrian McGowan
Minimal time, no additional fee required for Plan Check.
CHANGE STATUS TO (ISS)  9/18/2018 DONE
per BJM no plan mod required
Inspection Record Card- Bld  9/18/2018 DONE
Routing - PLAN CHECK9/18/2018 9/18/2018 PASS
DetailsBrian McGowan
Permit Ready to Issue  9/18/2018 DONE
per BJM-no fees due for plan mod
Routing - PLANNING9/17/2018 9/17/2018 PASS
DetailsNicolette Womack
Plan Modification Accepted  9/12/2018 DONE
modification to site plan
CHANGE STATUS TO (REV)  9/12/2018 DONE
Issue PAID IN FULL permit  8/30/2018 DONE
Inspection Record Card- Bld  8/30/2018 DONE
OVERRIDE  8/29/2018  
Plan assigned to (BJM)8/8/20188/8/20188/29/2018 DONE
DetailsBrian McGowan
08/27 sfd L2 ePlan
Routing - PLAN CHECK8/8/2018 8/29/2018 PASS
DetailsBrian McGowan
Routing PW Grading-Hillside8/29/2018 8/29/2018 CANC
DetailsMelissa Jannusch
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at ###-#### with questions.

1st review completed  8/29/2018 DONE
DetailsBrian McGowan
PLANS/APPL TAKEN TO FRONT DESK  8/29/2018 DONE
DetailsBrian McGowan
Override - Parcel Holds  8/29/2018  
Permit Ready to Issue  8/29/2018 DONE
met
Routing - PLANNING8/27/2018 8/27/2018 PASS
DetailsNicolette Womack
Routing - FIRE8/13/20188/13/20188/24/2018 PASS
DetailsErika Akin
Fire area 3529, Fire flow 1000 gpm, plans were reviewed for hydrant availability, FD access and defensible space
Plan Reviewer's activity  8/24/2018 DONE
DetailsBrian McGowan
Uploaded new sheets and rerouted to Planning
Route to Impact Fee Review8/8/20188/11/20188/9/2018 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL8/8/2018 8/8/2018 PASS
DetailsTroy James
Routing - PLANNING8/8/2018 8/8/2018 FAIL
DetailsSue Cummings
Two areas encroching into setbacks
Routing - Addressing8/8/2018 8/8/2018 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS8/8/2018 8/8/2018 PASS
DetailsRachael Beierle
Plans ACCEPTED BY PLAN TECH  8/8/2018 DONE
Override - Parcel Holds  8/8/2018  
Recd Pcfee & Taken To Pln CK  8/8/2018 DONE
Intake Approval  8/8/2018 PASS
Intake Approval  8/3/2018 FAIL
Wrong code year for IECC
Application received  7/31/2018 DONE
Application submitted via PDS Online on Jul 31 2018 2:43PM