Permit Information
Permit NumberBLD18-02751
StatusFinaled
Name LAYTON CONSTRUCTION
Site Address 6663 S EISENMAN RD Unit: 140
Project NameD-Bat Academy Boise
Customer Number 
ePlanReviewYes
Description
(D-BAT ACADEMY BOISE – BUILDING C – NORTH END OF BUILDING) (SUITE 140) (DRH17-00215) The fire sprinkler system is used for building area increase and for fire area. To construct improvements within an existing 20,318 square foot shell tenant space located in the North end of Building C for an assembly occupancy to be used as a baseball and softball pitching and hitting training facility. This shell tenant space was demised under permit BLD17-02817 when the 51,402 square foot building shell was constructed. This tenant space is required to be separated from the rest of the building by a 1-hr fire barrier wall to function as an occupancy separation. Work is to include interior steel stud walls, a gypsum board and steel stud ceiling above the office and retail sales area, two toilet rooms accessible to the disabled, vinyl coated chain-link fencing to define an egress corridor, soft wall netting for pitching and batting tunnels, new storefront glazing to replace an overhead door, suspended acoustical ceilings, suspended gypsum board ceilings, millwork, and finishes. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  4/19/2019 DONE
sent 1st late notice
Print Statement  1/15/2019 DONE
First Notice 12/23/20181/8/2019 DONE
mailed 1-11-19
Permanent Occupancy  12/13/2018 DONE
BLD-Final12/10/201812/11/201812/11/2018PPASS
DetailsMike Jordan
Tim Phone #: ###-####. ok for perm occ.
FIRE-Final Inspection12/10/201812/11/201812/11/2018APASS
DetailsJim Page
Previously noted items have been corrected, fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags. Final life fire safety inspection for area of work complete.

Tim Phone #: ###-####
BLD-Final12/6/201812/7/201812/7/2018PNR
DetailsJim Storey
Tim Phone #: ###-####
FIRE-Final Inspection12/6/201812/7/201812/7/2018AFAIL
DetailsTroy Cobbley
Relocate the fire extinguisher as discussed, repair the exit sign and provide inspection/final for the fan shutdown.

Tim Phone #: ###-####
FIRE-Final Inspection12/7/201812/7/201812/7/2018PCANC
DetailsJim Page
Tim Phone #: ###-####
BLD-Ceiling Grid Inspection11/20/201811/21/201811/21/2018APASS
DetailsJim Storey
Tim Phone #: ###-####
BLD-Ceiling Grid Inspection10/31/201811/1/201811/1/2018APASS
DetailsJim Storey
Tim Phone #: ###-####
BLD-Framing/Rough-in10/16/201810/16/201810/16/2018PPASS
DetailsJim Storey
Tim Phone #: ###-####
BLD-Framing/Rough-in10/5/201810/8/201810/8/2018PPASS
DetailsJim Storey
dave Phone #: ###-#### meet with engineer of record// ok to cover/ ceilling
Permit Ready to Issue  9/20/2018 DONE
met
Issue PAID IN FULL permit  9/20/2018 DONE
Print Occupancy Form  9/20/2018 DONE
Plan assigned to (CJW)8/9/20188/9/20189/19/2018 PASS
DetailsCarl Westfall
(1st done) 08/27/18 (L3 - 15 days) (ePlan - 31 sheet) D-Bat
Plan resubmittals received  9/19/2018 DONE
Routing - PLAN CHECK9/19/2018 9/19/2018 PASS
DetailsCarl Westfall
2nd plan review approved
PLANS/APPL TAKEN TO FRONT DESK  9/19/2018 DONE
Route to Impact Fee Review9/14/20189/17/20189/17/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - PLAN CHECK8/9/2018 9/14/2018 FAIL
DetailsCarl Westfall
1st review completed  9/14/2018 DONE
Plan resubmittals requested  9/14/2018 DONE
Routing - FIRE8/9/20188/9/20189/5/2018 PASS
DetailsErika Akin
Attached comments to case
Routing - MECHANICAL8/20/2018 8/20/2018 PASS
DetailsTroy James
Routing - MECHANICAL8/9/2018 8/13/2018 FAIL
DetailsTroy James
Left voicemail to mechanical engineer to call
Routing - PLUMBING8/9/2018 8/10/2018 PASS
DetailsBill VanDegrift
See redline marks and install per ISPC.
Routing - Addressing8/9/2018 8/10/2018 PASS
DetailsDoug Chausow
Suite 140
Routing - PUBLIC WORKS8/9/2018 8/10/2018 PASS
DetailsMorgan Webb
Routing - PLANNING8/9/2018 8/9/2018 PASS
DetailsBrent Moore
Intake Approval  8/7/2018 PASS
Application received  8/1/2018 DONE
Application submitted via PDS Online on Aug 1 2018 10:45AM