Permit Information
Permit NumberBLD18-02795
StatusFinaled
Name PETRA INC
Site Address 12251 W FRANKLIN RD
Project NameFloor Trader Outlet
Customer Number 
ePlanReviewYes
Description
(CJD INVESTMENTS, DBA FLOOR TRADER OUTLET) //Plan modification to remove select pavement from scope of site work on the south lot 2 until south lot is developed. 6-17-2019 JG// Permit to construct a new 36,532 sq. ft. two story building (23,503 sq. ft. 1st story and 11,227 sq. ft. 2nd story) and related site improvements. Approval is contingent upon adhering to the approved plans on file, attached engineering and plan review report. Scope of work includes: construction of footing foundation, slab on grade concrete floor, construction of concrete tilt-up exterior envelope walls, open web steel roof joists, membrane roof assembly, construction of interior bearing CMU walls to create an office and a retail area with a storage mezzanine area above, construction of interior non-bearing walls to create (6) offices, a break room, fire riser room, a janitors closet and (4) accessible restrooms, new Hi/Lo drinking fountain, a new elevator, new elevator equipment room, millwork, new suspended acoustic and gypsum ceilings, light fixtures, electrical work, plumbing work, mechanical work and interior finishes to be in compliance with Ch. 8 of the current IBC. Note 1: Special inspection required see attached 310 form. Note 2: Racking/Shelving over 8’ requires a separate racking permit. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  8/12/2019 DONE
First Notice 7/29/20198/2/2019 DONE
mailed 8/5/19
BLD-Final7/18/20197/19/20197/19/2019APASS
DetailsMike Jordan
Chad Phone #: ###-####
Permanent Occupancy  7/19/2019 DONE
BLD-Final7/2/20197/8/20197/8/2019PCANC
DetailsMike Jordan
Frankie-elevator only Phone #: ###-####
FIRE-Final Inspection7/2/20197/5/20197/5/2019PPASS
DetailsTroy Cobbley
life safety passed

Frankie-elevator only Phone #: ###-####
FIRE-Final Inspection7/3/20197/3/20197/3/2019PPASS
DetailsTroy Cobbley
Life safety passed.

Franky Phone #: ###-####
Temporary Occupancy6/21/20199/19/20196/21/2019 DONE
DetailsJudith Amador
BLD-Final6/19/20196/20/20196/20/2019APASS
DetailsMike Jordan
Franky- Phone #: ###-####. OK for temp occ. Will be ok or perm occ. once trades sign perm.
FIRE-Final Inspection6/18/20196/19/20196/19/2019APART
DetailsTroy Cobbley
A temporary for life safety is ok with Chief Ron's permission until the elevator has been installed and tested. Chad Phone #: ###-####
Plan assigned to (JG)6/11/20196/11/20196/18/2019 PASS
DetailsJavier Guzman
Plan Mod Floor Trader Outlet ePlan
Permit Ready to Issue  6/18/2019 DONE
DO NOT ISSUE- plan mod
CHANGE STATUS TO (ISS)  6/18/2019 DONE
plan mod
Routing - FIRE6/17/20196/17/20196/17/2019 PASS
DetailsErika Akin
Change in FD access approved via email 5-3 from Ron Johnson. Two paved access points must be maintained as shown.
Routing PW Drainage6/17/2019 6/17/2019 PASS
DetailsBrian Murphy
APPROVED UNDER GRADING PERMIT
Routing PW Street Lights6/17/2019 6/17/2019 PASS
DetailsTom Marshall
Routing - Design Review6/17/2019 6/17/2019 PASS
DetailsAndrea Tuning
Routing - PLAN CHECK6/17/2019 6/17/2019 PASS
DetailsJavier Guzman
Routing - PUBLIC WORKS6/17/2019 6/17/2019 PASS
DetailsMorgan Webb
Plan Reviewer's activity  6/12/2019 DONE
DetailsJavier Guzman
plan mod prescreen failed for the following

Provide and upload the following:
1. A completed plan modification application required (app found at https://www.cityofboise.org/media/5655/522_planmod.pdf)
2. The uploaded revised sheet A101 is not acceptable as this plan sheet has the city approved stamp on the bottom right corner, this revised sheet A101 will need to be a new sheet that does not show the previous approved city stamp
Plan Reviewer's activity  6/12/2019  
Plan Mod prescreen failed

Provide and upload the following:
1. Request for Plan modification application not addressed 6/12/2019
Provide and upload a completed plan modification application required (application found at https://www.cityofboise.org/media/5655/522_planmod.pdf)
BLD-Final6/11/20196/11/20196/11/2019PCANC
DetailsMike Jordan
BLD-Conference6/11/20196/11/20196/11/2019PDONE
DetailsMike Jordan
Walk through. Needs to complete fire caulking and lower breakroom counter. for ADA.
BLD-Final6/10/20196/11/20196/11/2019ACANC
DetailsMike Jordan
Chad Phone #: ###-####
PubWorks Occupancy Approval6/11/20196/11/20196/11/2019 DONE
DetailsTiffany Lowery
Plan Modification Accepted  6/11/2019 DONE
plan mod per Wesley Steel. Delete pavement on west and south sides of Lot 2 access until such time as Lot 2 is developed
Zoning Approval6/10/20196/10/20196/10/2019 DONE
DetailsAndrea Tuning
FIRE-Final Inspection6/7/20196/7/20196/7/2019PFAIL
DetailsTroy Cobbley
Provide sign offs for the project related fire sprinkler and fire alarm permits, Provide emergency light for the Fire Pump Room, Provide testing/inspection for the elevator, Provide singage for the Fire Pump/Riser Room.

Chad- Phone #: ###-####
FIRE-Conference5/24/20195/24/20195/24/2019PDONE
DetailsTroy Cobbley
Chad and I spoke about fire dept signage, addressing and inspection scheduling for fire pump certification.
BLD-Ceiling Grid Inspection5/23/20195/23/20195/23/2019PPASS
DetailsMike Jordan
Chad Phone #: ###-####. 1st. floor ceiling grid ok.
BLD-Framing/Rough-in5/10/20195/13/20195/13/2019APASS
DetailsMike Jordan
Chad Phone #: ###-####. fireblocking around duck work at 2nd. floor penetrations.
BLD-Framing/Rough-in5/1/20195/2/20195/2/2019APART
DetailsJim Sly
chad Phone #: ###-####
Roof screenwall framing.....OK.
BLD-Wall Bracing5/1/20195/1/20195/1/2019PFAIL
DetailsMike Jordan
chad Phone #: ###-####Steel stud framing for screen walls on roof. Needs to provide more screws as per the approved plans.
BLD-Wall cover4/30/20194/30/20194/30/2019PPART
DetailsDave Hannah
Chad Phone #: ###-#### inter layer of sheet rock at stairs ok
BLD-Framing/Rough-in4/29/20194/29/20194/29/2019PPASS
DetailsMike Jordan
chad Phone #: ###-####. Interior steel stud framed walls 1st. floor ok.
BLD-Foundation4/9/20194/10/20194/10/2019APASS
DetailsMike Jordan
rebar Phone #: ###-####. Reinforcement for interior slab on grade at 2nd floor.
FIRE-Conference4/5/20194/9/20194/9/2019ADONE
DetailsTroy Cobbley
Chad and I went over fire extinguisher placement, knox box location (deferred to Fire Dept), fire pump room requirements and sprinkler obstructions and small safety factor for the overhead system.

Chad Phone #: ###-####
FIRE-Conference4/4/20194/5/20194/5/2019ACANC
DetailsJim Page
Rescheduled conference for 09APR2019 per conversation with point of contact.

Chad Phone #: ###-####
BLD-Conference4/2/20194/3/20194/3/2019ADONE
DetailsMike Jordan
Chad ###-####
BLD-Other3/29/20194/1/20194/1/2019APART
DetailsMike Jordan
welding for mezzanine // Chad Phone #: ###-####. Work in progress on puddle welds on mezz. decking. Ok for concrete pending special inspection.
BLD-Foundation3/18/20193/19/20193/19/2019ACANC
DetailsMike Jordan
rebar // chad Phone #: ###-####
BLD-Concrete3/7/20193/7/20193/7/2019PPART
DetailsMike Jordan
Chad- Rebar inspction Phone #: ###-####. Cmu wall, FF to 4ft. elevation. Ok pending special inspection.
BLD-Foundation3/4/20193/4/20193/4/2019PDEFR
DetailsMike Jordan
masonry rebar // Chad Phone #: ###-####
BLD-Foundation2/28/20193/1/20193/1/2019APART
DetailsMike Jordan
Chad Phone #: ###-####. MAsonry elevator shaft, top of stemwall to 4ft. elevation. Will do hight lift, cleanouts ok, engineer of record ok. Ok pending special inspection.
BLD-Other2/25/20192/26/20192/26/2019ADEFR
DetailsMike Jordan
welding // Chad Phone #: ###-####.
BLD-Foundation2/19/20192/20/20192/20/2019PCANC
DetailsMike Jordan
rebar - pouring at 2pm // Chad Phone #: ###-####
BLD-Foundation1/30/20191/31/20191/31/2019PPART
DetailsMike Jordan
Chad Phone #: ###-####. Work in progress on rebar for tilt panels. Engineer of record to provide RFI for panels #27 and #29 noting in place reinforcement is ok. Special inspector on site. ok to place concrete pending special inspection.
BLD-Foundation1/29/20191/30/20191/30/2019PPART
DetailsMike Jordan
Chad Phone #: ###-####. Panels 22 through 30. panels 27 and 29 rebar is incorrect. Ok to place concregte pending special inspection.
BLD-Footing12/20/201812/20/201812/20/2018PPART
DetailsMike Jordan
Chad-footings & panel Phone #: ###-#### Work in progress. Special inspector on site. Ok to place concrete pending special inspection.
BLD-Foundation12/14/201812/14/201812/14/2018PDEFR
DetailsMike Jordan
rebar // Chad Phone #: ###-####
BLD-Foundation12/12/201812/13/201812/13/2018PPASS
DetailsMike Jordan
rebar // chad Phone #: ###-####. Panels 1,2,3,4,5 and 6 ok.
BLD-Other12/5/201812/5/201812/5/2018PPART
DetailsDave Hannah
rebar // Chad Phone #: ###-#### wire mess ok
BLD-Foundation11/8/201811/9/201811/9/2018PPART
DetailsMike Jordan
Chad=-slab Phone #: ###-####. Work in progress on interior thickend footings and interior slab on grade. Will have special inspection.
BLD-Foundation11/8/201811/8/201811/8/2018PCANC
DetailsMike Jordan
Chad-slab-would like as late as possible Phone #: ###-####
BLD-Foundation11/1/201811/1/201811/1/2018PPASS
DetailsMike Jordan
rebar // Chad Phone #: ###-####. Interior and exterior column pad footings.
Issue PAID IN FULL permit  11/1/2018 DONE
Print Occupancy Form  11/1/2018 DONE
Permit Ready to Issue  10/31/2018 DONE
brian @ bblack@petrainc.net
Routing - Design Review10/31/2018 10/31/2018 PASS
DetailsAndrea Tuning
Routing - Design Review10/31/2018 10/31/2018 PASS
DetailsAndrea Tuning
Changemark removed
CHANGE STATUS TO (RDY)  10/31/2018 DONE
not sure how it was changed back into REV status
Routing PW Drainage10/31/2018 10/31/2018 PASS
DetailsBrian Murphy
Routing - FIRE10/16/201810/16/201810/30/2018 PASS
DetailsErika Akin
Attached revised comments to case
Plan assigned to (JG)8/16/20188/16/201810/30/2018 PASS
DetailsJavier Guzman
1st rev comp, 9/20 CJD Investments New ePlan, pend fire and eng
Routing Off Site - STRUCTURAL10/16/2018 10/30/2018 PASS
DetailsJavier Guzman
signed off in ePlan by KPFF Jordan Terry

PLANS/APPL TAKEN TO FRONT DESK  10/30/2018 DONE
Routing - PLAN CHECK10/16/2018 10/24/2018 PASS
DetailsJavier Guzman
Routing - PLANNING10/16/2018 10/23/2018 PASS
DetailsAndrea Tuning
No review required for Current Planning
Routing PW Sewer Design10/16/2018 10/17/2018 PASS
DetailsDeAnn Brown
Routing PW Drainage10/16/2018 10/17/2018 PASS
DetailsBrian Murphy
Routing - PLUMBING10/16/2018 10/16/2018 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - Design Review10/16/2018 10/16/2018 PASS
DetailsAndrea Tuning
Route to Impact Fee Review9/27/20189/30/201810/4/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE8/21/20188/21/20189/27/2018 FAIL
DetailsErika Akin
Attached comments to case and emailed architect
1st review completed  9/27/2018 FAIL
DetailsJavier Guzman
Routing - PLAN CHECK8/21/2018 9/21/2018 FAIL
DetailsJavier Guzman
Routing Off Site - STRUCTURAL8/21/2018 9/11/2018 FAIL
DetailsJavier Guzman
Failed in ePlan by KPFF Jordan Terry
Routing - Design Review8/21/2018 9/11/2018 FAIL
DetailsAndrea Tuning
Failed in ePlan by DR Andrea Tuning (DRH18-00208)
Routing PW Environmental8/22/2018 8/29/2018 PASS
DetailsRick Christenson
Routing PW Solid Waste8/22/2018 8/23/2018 PASS
DetailsEvan Carpenter
Routing - MECHANICAL8/21/2018 8/23/2018 PASS
DetailsTroy James
Routing - PLUMBING8/21/2018 8/22/2018 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing PW Sewer Design8/22/2018 8/22/2018 FAIL
DetailsDeAnn Brown
Please show and label existing 3" pressure sewer pipeline that crosses east/west through the parking lot to connection manhole on sheet C-5 and all other applicable utility/demo sheets. This pipeline passes under the new 6" fire water line. I can provide record drawings (drbrown@cityofboise.org).
Routing PW Street Lights8/22/2018 8/22/2018 PASS
DetailsTom Marshall
Routing PW Drainage8/22/2018 8/22/2018 FAIL
DetailsBrian Murphy
need perc test
Routing - Addressing8/21/2018 8/22/2018 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS8/21/2018 8/22/2018 PASS
DetailsRachael Beierle
Routing - Erosion and Sediment8/21/2018 8/21/2018 PASS
DetailsMichael Zawacki
Please refer to ESC18-01130 which was issued with GRD18-00064
Routing - PLANNING8/21/2018 8/21/2018 FAIL
DetailsAndrea Tuning
Light poles must be lcoated outside the setbacks.

Planter islands must be 9-feet wide.
Plans ACCEPTED BY PLAN TECH  8/21/2018 DONE
Recd Pcfee & Taken To Pln CK  8/21/2018 DONE
Intake Approval  8/16/2018 PASS
Intake Approval  8/7/2018 FAIL
DetailsJulie Romig
1. Owner's signature on form 310.
2. Shallow Injection Well Inventory form indicated on checklist but not provided - please upload.
3. Sheet 11-CSUEZ-1_SUEZ WATER PLAN" is missing stamp/signature.
4. Mechanical Sheets M002 and M003 are too large to open. Reduce file size to less than 1 MB and reupload.
5. Per submittal standards, a 4” x 2” space located 3” off the right sheet edge is to be left blank for the city stamp. Reupload sheets that do not have this blank space.
Thank you,
Application received  8/3/2018 DONE
Application submitted via PDS Online on Aug 3 2018 11:51AM