Permit Information
Permit NumberBLD18-02996
StatusFinaled
Name CLEARY BUILDING CORP
Site Address 6633 S FEDERAL WAY
Project NamePeterbuilt Trucks
Customer Number 
ePlanReviewNo
Description
(PETERBILT TRUCKS) ***Special inspections required see #310 report*** Permit to construct a 60' x 42' pre-engineered metal pole building. No racking, mechanical, electrical, or plumbing work approved under this permit. Approval is contingent upon adhering to the approved plans on files and the attached engineering. This building is not fire sprinkled. MDH.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
PubWorks Occupancy Approval12/21/201812/21/201812/21/2018 DONE
DetailsTiffany Lowery
First Notice12/10/201812/10/201812/13/2018 DONE
DetailsBrandon Shaw
mailed 12-14
BLD-Final12/7/201812/10/201812/10/2018APASS
DetailsBrandon Shaw
Chris Phone #: ###-####
DOC - Permit Finaled12/10/201812/10/201812/10/2018PPASS
DetailsBrandon Shaw
FIRE-Final Inspection12/10/201812/10/201812/10/2018APART
DetailsJim Page
TCO authorized by Jim Storey on 07DEC2018, hydrant install will be verified with Paint Booth permit.
FIRE-Final Inspection12/6/201812/7/201812/7/2018ACANC
DetailsJim Page
Chris Phone #: ###-####
BLD-Final12/6/201812/7/201812/7/2018APART
DetailsJim Storey
Chris Phone #: ###-#### tco ok pending fire hyd instal on other permited job at paint booth.
FIRE-Final Inspection11/30/201812/3/201812/3/2018AFAIL
DetailsTroy Cobbley
Provide new fire hydrant as referenced under the review notes and BLD18-01396, provide a fire extinguisher, min. 4A with current inspection tag as discussed, remove the thumbturn deadbolt. Keyed is ok with indicator and sticker. Lever hardware can be provided as long as it is single action ADA type. Building not to be used until approved.

Chris Phone #: ###-####
BLD-Final11/20/201811/21/201811/21/2018AFAIL
DetailsJim Storey
Chris Phone #: ###-#### need sign off pw/fire achd// lever door handle required
BLD-Framing/Rough-in11/13/201811/13/201811/13/2018PPART
DetailsBrandon Shaw
Pending replacment of warped/broken 2x's...
Pending other trades rough in...
OK to cover exterior
BLD-Footing10/15/201810/16/201810/16/2018APASS
DetailsJim Storey
John Phone #: ###-#### si exsempt
Issue PAID IN FULL permit  10/3/2018 DONE
(F) Reprint permit  10/3/2018 DONE
OVERRIDE  9/28/2018  
OVERRIDE  9/28/2018  
Print Occupancy Form  9/28/2018 DONE
Telephone call  9/28/2018 DONE
Spoke with Chris to inform him the permit is ready. That we need the 302, 306 and a letter from ACHD
Plan assigned to (M_H)8/21/2018 9/28/2018 DONE
DetailsMichael Hanson
09/20 #502 L3 Paper. 1st review completed - structural corrections required refer to email. MDH Forwarded structural engineer response to off site structural (AHJ) 09/18/2018. MDH
Routing - PLAN CHECK8/23/2018 9/28/2018 PASS
DetailsMichael Hanson
Case Summary (BLD)  9/28/2018 DONE
DetailsMichael Hanson
PLANS/APPL TAKEN TO FRONT DESK  9/28/2018 DONE
DetailsMichael Hanson
Override - Condition Holds  9/28/2018  
Permit Ready to Issue  9/28/2018 DONE
Need ACHD - met (receipt attached)

Value and GC Met
*******NEED REVISED CERT OF VALUE FOR COMPLETE VALUE INCLUDING PROFIT & OVERHEAD. IF NO CHANGE FROM INITIAL VALUE NEED COPY OF CONTRACT BID. PLEASE SEE ADELE OR TISHA FOR QUESTIONS********
AS WELL AS GC FORM
Routing - FIRE9/6/20189/6/20189/27/2018 PASS
DetailsErika Akin
Attached comments to case and plans
Routing Off Site - STRUCTURAL9/17/2018 9/26/2018 PASS
DetailsMichael Hanson
Response from engineer sent to off site - structural (AHJ) 09/18/2018. MDH
Route to Impact Fee Review9/17/20189/20/20189/18/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
1st review completed  9/17/2018 PASS
DetailsMichael Hanson
Routing Off Site - STRUCTURAL8/23/2018 9/6/2018 FAIL
DetailsMichael Hanson
See email from AHJ engineering. MDH
Routing - Design Review9/6/2018 9/6/2018 PASS
DetailsKatelyn Menuge
Routing - PLANNING9/6/2018 9/6/2018 PASS
DetailsKatelyn Menuge
Telephone call  8/23/2018 DONE
called courier for pick up for outside engineering review
Routing - PUBLIC WORKS8/21/2018 8/23/2018 PASS
DetailsRachael Beierle
Routing - Erosion and Sediment8/23/2018 8/23/2018 PASS
DetailsAndy J. Long
Project has an approved ESC plan. Certified RP designated. Site preparation inspection is required upon commencement of construction.
Routing PW Environmental8/22/2018 8/23/2018 PASS
DetailsRick Christenson
Routing PW Drainage8/22/2018 8/22/2018 PASS
DetailsBrian Murphy
Routing - Addressing8/21/2018 8/21/2018 PASS
DetailsDoug Chausow
Plans ACCEPTED BY PLAN TECH  8/21/2018 DONE
Recd Pcfee & Taken To Pln CK  8/21/2018 DONE
Intake Approval  8/21/2018 PASS
DetailsMichael Hanson
Application received 8/17/2018