Permit Information
Permit NumberBLD18-03196
StatusFinaled
Name HC COMPANY INC
Site Address 6074 N DISCOVERY WAY Unit: 120
Project NameConnect Your Care - Suite #120
Customer NumberBLD18-03324
ePlanReviewYes
Description
**(CONNECT YOUR CARE – COLUMBIA BLDG - SUITE #120)** (2 PERMITS FILED UNDER BLD18-03196 IN EPLANREVIEW) Permit is to remodel an existing 15,037 sq. ft. tenant space by dividing it into two separate tenant spaces, this tenant space is to be 10,000 sq. ft. and the remaining 5,037 sq. ft. is to be an unoccupied tenant space created under BLD18-03324. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frame and relocate, removal of select millwork, removal of select interior windows, construction of select interior nonbearing wall to demise tenant spaces, create (4) offices and a conference room, select wall infill, relocate select light fixtures, electrical work, plumbing work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  1/16/2019 DONE
First Notice 12/30/20181/7/2019 DONE
mailed 1-11-19
Permanent Occupancy  12/20/2018 DONE
BLD-Final12/18/201812/19/201812/19/2018PPASS
DetailsJim Sly
John Phone #: ###-####
FIRE-Final Inspection12/18/201812/19/201812/19/2018APASS
DetailsTroy Cobbley
life safety passed


John Phone #: ###-####
BLD-Final11/29/201811/30/201811/30/2018APEND
DetailsDave Hannah
John Phone #: ###-#### ok for tco ok for perm co after fire fina;ls
FIRE-Final Inspection11/29/201811/30/201811/30/2018APART
DetailsTroy Cobbley
A temporary for life safety is being given with Ron's approval until the project related fire alarm permit is finaled. FIR18-00909

John Phone #: ###-####
BLD-Final11/27/201811/29/201811/29/2018ANR
DetailsMike Jordan
John Phone #: ###-####. Needs fire alarm permit. Fire/life/safety fianl failed.
FIRE-Final Inspection11/28/201811/29/201811/29/2018AFAIL
DetailsTroy Cobbley
The exit signs and emergency lights need to be repaired or replaced in both east facing and north facing entry lobby's. Also need a fire alarm permit for the modifications required.

Call 10 mins away- John Phone #: ###-####
FIRE-Final Inspection11/27/201811/28/201811/28/2018PFAIL
DetailsTroy Cobbley
Need the exit sign relocated as discussed and a fire alarm permit for the required modifications.

John Phone #: ###-####
BLD-Ceiling Grid Inspection11/6/201811/7/201811/7/2018PPASS
DetailsJim Sly
John Phone #: ###-####
BLD-Framing/Rough-in10/9/201810/10/201810/10/2018APASS
DetailsJim Sly
John Phone #: ###-####
Print Occupancy Form  10/9/2018 DONE
Issue PAID IN FULL permit  9/28/2018 DONE
Print Occupancy Form  9/28/2018 DONE
Plan assigned to (JG)9/12/20189/12/20189/25/2018 PASS
DetailsJavier Guzman
9/24 L2 Connect Youth Care ePlan
Routing - PLAN CHECK9/12/2018 9/25/2018 PASS
DetailsJavier Guzman
1st review completed  9/25/2018 DONE
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  9/25/2018 DONE
Permit Ready to Issue  9/25/2018 DONE
NEED
GC FORM - met
REVISED VALUE - met

All met -

DO NOT ISSUE W/OUT BLD18-03324
Routing - Addressing9/12/2018 9/12/2018 PASS
DetailsDoug Chausow
Suite 120
Routing - PUBLIC WORKS9/12/2018 9/12/2018 PASS
DetailsMorgan Webb
sign off also indemark BLD18-03324
Intake Approval  9/11/2018 PASS
DetailsJavier Guzman
Intake Approval  9/7/2018 FAIL
DetailsJoe Bruce
1) Form #304 Registered Design Professional form is missing the owner information.
2) Incorrect codes are referenced on Sheet G001. The adopted building codes are incorrectly listed for the NEC and IMC codes. Resubmit sheet with correct code references.
3) Provide exit signs and emergency lighting locations (existing and new) on plan.
4) Sheet A613 does not have the required space reserved for City approval stamps as specified in the Electronic Plans Submittal Standards. Revise sheets with a blank 4” x 2” space located 3” off the right sheet edge to allow for the title block.
Application received  8/30/2018 DONE
Application submitted via PDS Online on Aug 30 2018 2:42PM