Information based on query as of Thursday, July 4, 2024.
Permit Information
Permit NumberBLD18-03600
StatusFinaled
Name ALTECCA LLC
Site Address 1003 W MAIN ST
Project NameGood Burger III + The Drop
Customer NumberBLD18-04572 EARLY START
ePlanReviewYes
Description
(GOOD BURGER III) **Permit for a tenant improvement in an existing 1,502 sq. ft. tenant space for a new restaurant and commercial kitchen. Work to include construction of new interior nonbearing partition walls; new seating and kitchen; plumbing, electrical, and mechanical work; and interior finishes in compliance with Ch. 8 of the 2015 IBC. All work to be done per the approved plans and applicable codes and ordinances. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations to the sprinkler/alarm system will require a separate permit and shall comply with NFPA 13 as regulated by the fire department. **JHB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice 4/5/20194/8/2019 DONE
mailed 4-11-19
BLD-Final3/26/20193/26/20193/26/2019PPASS
DetailsDave Hannah
Permanent Occupancy  3/26/2019 DONE
Zoning Approval3/21/20193/21/20193/21/2019 DONE
DetailsAndrea Tuning
CHANGE STATUS TO (ISS)  3/19/2019 DONE
different company for outdoor seating
BLD-Final3/13/20193/14/20193/14/2019APART
DetailsDave Hannah
Taylor-still needs mec final & P&Z ok''d a temp Phone #: ###-#### ok for temp occ ok for perm occ after others go perm
Temporary Occupancy3/14/20196/12/20193/14/2019 DONE
DetailsCandy A. Nichols
FIRE-Final Inspection3/13/20193/13/20193/13/2019PPASS
DetailsJim Page
Final inspection for sprinklers complete, final inspection for fire alarms complete, hood suppression system inspection complete. Final life fire safety inspection for area of work complete.

Taylor Phone #: ###-####
Zoning Approval Temp3/13/20193/13/20193/13/2019 DONE
DetailsAndrea Tuning
14 day temporary occpancy has been issued per the direction of Cody Riddle. Once the duct work has been painted as required, final occupancy can be signed off.
FIRE-Final Inspection3/12/20193/12/20193/12/2019PCANC
DetailsJim Page
Fire alarms and hood suppression system inspection did not happen, this request is cancelled and will need to be rescheduled to coincide with fire alarm and hood suppression inspection.

call 10 mins ahead- Tyler Phone #: ###-####
Meeting  3/12/2019 DONE
Owner of Good Burger informed us a new architect is taking over the project. They will be submitting a plan mod. (Tisha informed me if the old architect will release his plans we can add the new architect Joe T to complete the plan mod. Will need to add Joe as an applicant in eplan when the application is filled out)
BLD-Conference3/11/20193/11/20193/11/2019PDONE
DetailsJim Page
Fire conference complete.

Taylor Phone #: ###-####
BLD-Conference3/8/20193/8/20193/8/2019PDONE
DetailsDave Hannah
Taylor Phone #: ###-####
FIRE-Final Inspection3/8/20193/8/20193/8/2019PFAIL
DetailsJim Page
Fire sprinkler, hood suppression (FIR19-00178 is for the hood suppression) and fire alarm permits are still in issued status and have not had final inspections, FIR permits for fire alarm, fire sprinkler and hood suppression must be inspected and finaled before life fire safety can be completed.

Taylor Phone #: ###-####
BLD-Ceiling Grid Inspection2/8/20192/8/20192/8/2019PPASS
DetailsDave Hannah
Taylor Phone #: ###-####
BLD-Other1/28/20191/28/20191/30/2019PPASS
DetailsDave Hannah
Taylor-dry wall Phone #: ###-####
BLD-Framing/Rough-in1/24/20191/25/20191/25/2019APASS
DetailsDave Hannah
Taylor Phone #: ###-####
Plan assigned to (JHB)1/15/20191/15/20191/25/2019 CANC
DetailsJoe Bruce
Good Burger III - Plan MOD
BLD-Framing/Rough-in1/24/20191/24/20191/24/2019PDEFR
DetailsJim Storey
Taylor Phone #: ###-#### out of time
BLD-Framing/Rough-in1/22/20191/23/20191/23/2019APART
DetailsMike Jordan
Taylor Phone #: ###-####. Ok to one side walls. Needs to complete fire caulking on through penetrations in floor. Ok to insulate and install base layer on 2hr. fire wall.
Plan resubmittals received  1/16/2019 CANC
DetailsJoe Bruce
Recevied plan modification for sheets M.10 and M.11. **JHB**

****CANCEL PLAN MOD PER ROBYN****
Plan resubmittals requested  1/16/2019 DONE
DetailsJoe Bruce
1) File names should match the previously uploaded sheets so that it overwrites the existing file. Upload the plan modification sheets with the same file name as the previous sheets.
2) There revisions made between M.11 and M.10 could not be established. Please cloud modify and revise the date on the plans for the sheets being modified.
CHANGE STATUS TO (ISS)  1/16/2019 DONE
****CANCEL PLAN MOD PER ROBYN****
Plan Modification Accepted  1/15/2019 DONE
Sheets M.10 and M.11 shirft of some mechanical equipment.
Issue PAID IN FULL permit  1/14/2019 DONE
Print Occupancy Form  1/14/2019 DONE
Plan assigned to (JHB)11/30/201811/30/20181/10/2019 PASS
DetailsJoe Bruce
*(2nd Rev Comp) 12/10 The Good Burger (L-3) (DR)
Plan resubmittals received  1/10/2019 DONE
DetailsJoe Bruce
Routing - Design Review1/10/2019 1/10/2019 PASS
DetailsAndrea Tuning
PLANS/APPL TAKEN TO FRONT DESK  1/10/2019 DONE
Permit Ready to Issue  1/10/2019 DONE
NEED- met
GC FORM
REVISED VALUE

MET
ACHD
Routing - PLAN CHECK12/19/2018 12/20/2018 PASS
DetailsJoe Bruce
Routing - MECHANICAL12/19/2018 12/20/2018 PASS
DetailsTroy James
Mechanical Engineer will provide a plan mod for the grease duct changes. Grease ducts will have to be installed with reserviors per IMC.
Plan resubmittals requested  12/20/2018 DONE
DetailsJoe Bruce
Spoke with Robyn about additional DR requirements for permit to be issued. **JHB**
Plan resubmittals received  12/19/2018 DONE
DetailsJoe Bruce
Recvied corrected sheets in ePlan. **JHB**
Routing - Design Review12/19/2018 12/19/2018 FAIL
DetailsAndrea Tuning
A design review approval is required for the ductwork that will be applied to the exterior of the building. The application shoudl should the color, location and attachment details of the proposed ductwork.
Plan resubmittals received  12/18/2018 DONE
DetailsJoe Bruce
Sheets file names did not match in ePlan. **JHB**
Plan resubmittals requested  12/18/2018 DONE
DetailsJoe Bruce
Sent request to archtitect to upload sheets with matching file names. **JHB**
Route to Impact Fee Review12/11/201812/14/201812/11/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
1st review completed  12/11/2018 FAIL
DetailsJoe Bruce
Plan resubmittals requested  12/11/2018 DONE
DetailsJoe Bruce
Emailed plan review report to architect. **JHB**
Routing - PLAN CHECK11/15/2018 12/11/2018 FAIL
DetailsCarl D Madsen
Routing - FIRE11/15/201811/15/201812/10/2018 PASS
DetailsErika Akin
Attached comments to case
Plan assigned to (CDM)11/15/201811/15/201811/30/2018 DEFR
DetailsCarl D Madsen
12/10 Good Burger III (L-3)
Zoning Approval11/28/201811/28/201811/28/2018 DONE
DetailsAndrea Tuning
Red lined to exclude the outdoor dining.
Routing PW Environmental11/15/2018 11/27/2018 PASS
DetailsTerry Alber
Review passed based on shown grease line and existing grease interceptor. Grease abatement is required.
Routing - PUBLIC WORKS11/15/2018 11/26/2018 PASS
DetailsMorgan Webb
Routing - MECHANICAL11/15/2018 11/26/2018 FAIL
DetailsTroy James
Routing - PLUMBING11/15/2018 11/26/2018 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - Addressing11/15/2018 11/16/2018 PASS
DetailsDoug Chausow
Address: 1003 W Main St
Routing - Design Review11/15/2018 11/15/2018 FAIL
DetailsAndrea Tuning
Outdoor seating will require a site plan and elevations approved by Design Review staff and City Clerk approval of a Sidewalk Café permit prior to building permit submittal or placement of any furnishings. Furnishings shall allow for a minimum 5-foot-wide pedestrian corridor, free of obstructions at all times. All furnishings shall be limited to 3-feet in height.

Any structural encroachments into the right-of-way require Design Review approval and a recorded license agreement with the Ada County Highway District.
Routing - PLANNING11/15/2018 11/15/2018 PASS
DetailsDavid Moser
Use allowed in C-5 zone and P-1 Parking overlay, See DRH approval
Intake Approval  11/13/2018 PASS
Intake Approval  10/24/2018 FAIL
DetailsJavier Guzman
Provide and upload the following:
• Provide a Site specific fire flow at hydrants letter from Suez Water or other public water provider
• Provide Planning & Zoning letters of approval for exterior work (overhead and bi-fold doors)
• Provide engineering calculations for the hanging type 1 hood (500 lbs.) and added rooftop weight from MAU (860 lbs.) and rooftop exhaust fan (400 lbs.) and/or any rooftop openings.
Application received  10/1/2018 DONE
Application submitted via PDS Online on Oct 1 2018 10:04AM
Intake Approval  10/1/2018 FAIL
DetailsJavier Guzman
Per applicant asked to fail and return prescreen to applicant