BLD-Final | 3/7/2019 | 3/7/2019 | 3/7/2019 | A | PASS |
Mike Jordan
|
|
|
door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
DOC - Permit Finaled | 3/7/2019 | 3/7/2019 | 3/7/2019 | P | PASS |
Mike Jordan
|
|
|
All issues resolved.
|
BLD-Blower Door Test Results | 3/7/2019 | 3/7/2019 | 3/7/2019 | A | DONE |
Mike Jordan
|
|
|
4.32ACH @ 50pa
|
BLD-Final | 2/26/2019 | 2/27/2019 | 2/27/2019 | A | FAIL |
Mike Jordan
|
|
|
Door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle. Post address, Com0lete exterior stone work, provide blower door test result, Provide code comliant stairs and landing from back door. Correction notice posted.
|
BLD-Energy code compliance | 1/18/2019 | 1/18/2019 | 1/18/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 1/18/2019 | 1/18/2019 | 1/18/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 1/15/2019 | 1/17/2019 | 1/17/2019 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complte lateral bracing on A3 and A4 trusses. Ok to insulate. Corection notice posted.
|
BLD-Wall Bracing | 1/2/2019 | 1/2/2019 | 1/2/2019 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Foundation | 12/12/2018 | 12/13/2018 | 12/13/2018 | A | PASS |
Brandon Shaw
|
|
|
Per plans...
|
BLD-Foundation | 12/12/2018 | 12/12/2018 | 12/12/2018 | P | CANC |
Mike Jordan
|
|
|
|
DOC - Permit Finaled | 12/12/2018 | 12/12/2018 | 12/12/2018 | P | PASS |
Mike Jordan
|
|
|
(This activity was added in error so we have changed the case status back to Issued.)
|
BLD-Foundation | 12/11/2018 | 12/12/2018 | 12/12/2018 | P | DONE |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron lira
|
BLD-Footing | 12/10/2018 | 12/10/2018 | 12/10/2018 | P | PART |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 12/5/2018 | 12/6/2018 | 12/6/2018 | P | FAIL |
Brandon Shaw
|
|
|
As per ACI 318... forms, rebar, and soil sub-grade to be a minimum 35 F...
At itme of inspection, average sub-grade temp 11-28 F...
|
Issue PAID IN FULL permit | | | 11/14/2018 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 11/14/2018 | | DONE |
|
|
|
|
OVERRIDE | | | 10/19/2018 | | |
|
|
|
|
Plan assigned to (J_N) | 10/4/2018 | 10/4/2018 | 10/19/2018 | | DONE |
|
|
|
10/17 sfd L1 ePlan. 1st review complete 10/16, wall bracing
|
Routing - PLAN CHECK | 10/19/2018 | | 10/19/2018 | | PASS |
Jenny Nelson
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/19/2018 | | DONE |
Jenny Nelson
|
|
|
|
Permit Ready to Issue | | | 10/19/2018 | | DONE |
|
|
|
met
|
1st review completed | | | 10/16/2018 | | FAIL |
Jenny Nelson
|
|
|
Wall bracing
|
Routing - PLAN CHECK | 10/4/2018 | | 10/16/2018 | | FAIL |
Jenny Nelson
|
|
|
Wall bracing
|
Route to Impact Fee Review | 10/4/2018 | 10/7/2018 | 10/5/2018 | | PASS |
Eric Bilimoria
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - MECHANICAL | 10/4/2018 | | 10/5/2018 | | PASS |
Troy James
|
|
|
|
Routing - Addressing | 10/4/2018 | | 10/5/2018 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 10/4/2018 | | 10/4/2018 | | PASS |
Morgan Webb
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 10/4/2018 | | DONE |
|
|
|
|
Intake Approval | | | 10/4/2018 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/4/2018 | | DONE |
|
|
|
|
Routing - PLANNING | 10/4/2018 | | 10/4/2018 | | PASS |
Sue Cummings
|
|
|
|
Application received | | | 10/2/2018 | | DONE |
|
|
|
Application submitted via PDS Online on Oct 2 2018 10:29AM
|