**PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 2365 sq. ft., two story (first story 1299 sq. ft., second story 1066 sq. ft.) single family dwelling with 4 bedrooms, 3 bathrooms, approximately 689 sq. ft. attached garage per the approved plans and any notations. R-2D zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/29/20207/30/20207/30/2020APASS
DetailsBrandon Shaw
Lockbox on the hose bib. Code is 1987 Phone #: ###-#### Inspection requested via web by Tyler Hildebrand
DOC - Permit Finaled7/30/20207/30/20207/30/2020PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results7/30/20207/30/20207/30/2020ADONE
DetailsBrandon Shaw
ACH50- 4.2
BLD-Final6/17/20206/18/20206/18/2020AFAIL
DetailsBrandon Shaw
Address to be readily visable...
Post Blower door test...
Glazing at stiar landing to be tempered...
BLD-Aging Inspection12/27/201912/27/201912/27/2019 DEFR
DetailsBrandon Shaw
Extend Permit 90/180 days12/27/201912/27/201912/27/2019PDONE
DetailsBrandon Shaw
BLD-Aging Inspection8/15/20198/15/20198/15/2019 PASS
DetailsBrandon Shaw
Extend Permit 90/180 days8/15/20198/15/20198/15/2019PDEFR
DetailsBrandon Shaw
BLD-Energy code compliance4/3/20194/3/20194/3/2019PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Tyler Hildebrand
BLD-Framing/Rough-in4/1/20194/2/20194/2/2019APASS
DetailsJim Storey
* see Joist calculations for penetrations located with the plans on the drywall mud located in kitchen area. Please call after inspection. Phone #: ###-#### Inspection requested via web by Tyler Hildebrand
BLD-Framing/Rough-in3/22/20193/25/20193/25/2019APART
DetailsJim Storey
Call if any questions or concerns. Phone #: ###-#### Inspection requested via web by Tyler Hildebrand plm drilled top chord of I joist two locatins need engineer fix from manufacture/ fire blk drop ceilling at walls// need mech insp. // air seal not done.
BLD-Aging Inspection3/14/20193/14/20193/14/2019 PASS
DetailsJim Storey
Plan Modification Accepted  1/14/2019 DONE
New manual j report
Routing - MECHANICAL1/14/2019 1/14/2019 PASS
DetailsTroy James
Resubmitted manual j report
BLD-Footing10/30/201810/30/201810/30/2018PPASS
DetailsJim Storey
Pat Phone #: ###-####
Issue PAID IN FULL permit  10/29/2018 DONE
Inspection Record Card- Bld  10/29/2018 DONE
OVERRIDE  10/26/2018  
Plan assigned to (J_N)10/8/201810/8/201810/26/2018 DONE
Details
10/19 sfd L1 ePlan. 2nd review, braced wall line offsets. 1st Review 10/18 need bracing calculations
Routing - PLAN CHECK10/26/2018 10/26/2018 PASS
DetailsJenny Nelson
PLANS/APPL TAKEN TO FRONT DESK  10/26/2018 DONE
DetailsJenny Nelson
Permit Ready to Issue  10/26/2018 DONE
Need
GC FORM
Routing - PLAN CHECK10/23/2018 10/23/2018 FAIL
DetailsJenny Nelson
1st review completed  10/18/2018 FAIL
DetailsJenny Nelson
Need bracing calculations
Routing - PLAN CHECK10/8/2018 10/18/2018 FAIL
DetailsJenny Nelson
Route to Impact Fee Review10/8/201810/11/201810/9/2018 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL10/8/2018 10/9/2018 PASS
DetailsTroy James
Routing - PLANNING10/8/2018 10/8/2018 PASS
DetailsSue Cummings
Routing - Addressing10/8/2018 10/8/2018 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS10/8/2018 10/8/2018 PASS
DetailsMorgan Webb
Plans ACCEPTED BY PLAN TECH  10/8/2018 DONE
Intake Approval  10/8/2018 PASS
Recd Pcfee & Taken To Pln CK  10/8/2018 DONE
Application received  10/2/2018 DONE
Application submitted via PDS Online on Oct 2 2018 1:47PM
Intake Approval  10/2/2018 FAIL
NEED
RESCHECK
MANUAL J
INDICATE ATTICE/CRAWL SPACE
MEC EQUIPMENT (DID NOT SEE FURNACE, AC OR W.H)