Permit Information
Permit NumberBLD18-03667
StatusFinaled
Name ESI
Site Address 480 N LATAH ST
Project NameIn the Bag Promotions
Customer Number 
ePlanReviewYes
Description
(IN THE BAG PROMOTIONS) 09/11/2019 PLAN MODIFICATION #2 TO ADD AN EXTERIOR DOOR LANDING, STAIRS AND HANDRAIL. JG // 07/8/19 PLAN MODIFICATION TO TRUSS FRAMING AT THE UL U309 1-HOUR RATED EXTERIOR WALL CONSTRUCTION SEE DETAIL IN SMALL DOCUMENTS FILE. JG // Permit for a 3,942 sq. ft. addition to an existing 4,894 sq. ft. building and create an 8,836 sq. ft. building. Approval is contingent upon adhering to the approved plans on file and attached engineering. Work to include: removal of select exterior walls, removal of select removal of select door/door frame, removal of select exterior windows, removal of select exterior walls, construction of a new footings, concrete floor slab, 2x exterior walls, wood and stucco exterior siding, pre-engineered roof trusses, asphalt shingle and TPO roof covering, an accessible restroom, suspended acoustic and gypsum ceilings, some minor site work, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the 2015 IBC. Note: special inspection is required, see form #310 attached. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 7/13/20208/11/2020 DONE
mailed 8-14-2020 with second letter
Second Follow up  8/11/2020 DONE
Third Notice 5/12/20207/8/2020 DONE
mailed 7-9-2020 with first follow up
First Follow up  7/8/2020 DONE
Third Notice 4/8/20205/7/2020 DONE
mailed 5-8-2020
Third Notice 3/10/20204/3/2020 DONE
mailed 4-6-2020
Second Notice 2/16/20203/5/2020 DONE
mailed 3-6-20
First Notice 1/31/20202/6/2020 DONE
mailed 2-7-20
PubWorks Occupancy Approval1/22/20201/22/20201/22/2020 DONE
DetailsTiffany Lowery
PubWorks Occupancy Approval1/21/20201/21/20201/21/2020 DONE
DetailsBrian Murphy
Permanent Occupancy  1/21/2020 DONE
BLD-Final11/25/201911/25/201911/25/2019PPASS
DetailsTell Riley
Bob Phone #: ###-####//plan mod for steps at service door and railing complete//final is complete//no signature card to sign//
BLD-Final11/19/201911/19/201911/19/2019PNR
DetailsTell Riley
Bob Phone #: ###-####//need to modify hand rail to meet plan mod//discussed onsite//
Print Occupancy Form  9/24/2019 DONE
CHANGE STATUS TO (ISS)  9/24/2019 DONE
Print Occupancy Form  9/24/2019 DONE
OVERRIDE  9/17/2019  
Permit Ready to Issue  9/17/2019 DONE
PLAN MOD
Plan assigned to (JG)9/9/20199/9/20199/16/2019 PASS
DetailsJavier Guzman
1st rev comp, plan mod In the Bag Promotions
Routing - PLAN CHECK9/16/2019 9/16/2019 PASS
DetailsJavier Guzman
Routing - PLAN CHECK9/14/2019 9/14/2019 FAIL
DetailsJavier Guzman
Previous correction not addressed
Routing - PLAN CHECK9/10/2019 9/11/2019 FAIL
DetailsJavier Guzman
Routing - Design Review9/11/2019 9/11/2019 PASS
DetailsKatelyn Menuge
Plan Mod okay
Plan Modification Accepted  9/9/2019 DONE
plan modification per Jeff Likes. Adding railing near the will call door. Sheets SD1.1 and SD1.2
BLD-Final8/12/20198/12/20198/13/2019PPEND
DetailsTell Riley
joe Phone #: ###-####//discussed ramp at exit door--too steep--plans show 1:12//
BLD-Final7/18/20197/19/20197/19/2019PPASS
DetailsTell Riley
Joe Phone #: ###-####//building complete per plans//temp occupancy ok//final occupancy once parking lot is finished and signage is installed//
FIRE-Final Inspection7/19/20197/19/20197/19/2019PPASS
DetailsTroy Cobbley
life safety passed.

Joe Phone #: ###-####
BLD-Final7/18/20197/18/20197/18/2019PNR
DetailsTell Riley
Joe Phone #: ###-####//need electrical final//need fire final//new sidewalks and ADA ramp to be poured 7/19/19//
FIRE-Final Inspection7/17/20197/18/20197/18/2019APART
DetailsTroy Cobbley
Hvac unit won't go into heat mode for duct detector testing. Owner agreed to lock out the unit until it is repaired and shut down could be tested. All other life safety items appear ok. Joe Phone #: ###-####
Print Occupancy Form  7/18/2019 DONE
BLD-Framing/Rough-in7/9/20197/10/20197/10/2019APASS
DetailsTell Riley
Joe Phone #: ###-####//truss framing and beams installed per plans for modification//engineering was reveiwed//two electrical wires were fire caulked at the penetrations//
OVERRIDE  7/9/2019  
Plan assigned to (JG)6/27/20196/27/20197/9/2019 PASS
DetailsJavier Guzman
plan mod In the Bag Promotions
Routing - PLAN CHECK7/8/2019 7/9/2019 PASS
DetailsJavier Guzman
Routing Off Site - STRUCTURAL7/8/2019 7/9/2019 PASS
DetailsJavier Guzman
Plan Mod - Truss Modification signed off in ePlan by KPFF Cory Harelson
Permit Ready to Issue  7/9/2019 DONE
plan mod-please do not re issue
CHANGE STATUS TO (ISS)  7/9/2019 DONE
plan mod
Print Occupancy Form  7/9/2019 DONE
Print Occupancy Form  7/9/2019 DONE
Print Occupancy Form  7/9/2019 DONE
Print Occupancy Form  7/9/2019 DONE
Print Occupancy Form  7/9/2019 DONE
BLD-Ceiling Grid Inspection7/1/20197/1/20197/2/2019PPASS
DetailsDave Hannah
Joe- modification reveiw has nothing to do with this inspection Phone #: ###-####
Plan Modification Accepted  6/27/2019 DONE
plan mod for truss modification submitted by Jeff Likes
BLD-Framing/Rough-in6/25/20196/26/20196/26/2019AFAIL
DetailsJim Storey
Joe Phone #: ###-#### stop work/ submitals to get aproved by planreview not done/ need ul listings for wall assemley trusses bearing in wall . prevously noted with c/n an not responded to.
BLD-Ceiling Grid Inspection6/25/20196/25/20196/26/2019PNR
DetailsDave Hannah
joe Phone #: ###-####
BLD-Framing/Rough-in6/21/20196/24/20196/24/2019APART
DetailsDave Hannah
Joe Phone #: ###-#### blocking in wall at trusses ok to cover with sheet rock
BLD-Energy code compliance6/19/20196/19/20196/19/2019PPASS
DetailsBrandon Shaw
Ceiling insulation...
BLD-Other6/13/20196/14/20196/14/2019APASS
DetailsDave Hannah
Joe- drywall nai off inspection Phone #: ###-####
BLD-Wall cover6/10/20196/10/20196/11/2019PPART
DetailsDave Hannah
Joe Phone #: ###-#### picl up butt seams 8 oc/ plm pipe repairs to gyp and fire stop / and truss removal or fire rating pending. ok to cover int walls
BLD-Wall cover6/7/20196/10/20196/10/2019AFAIL
DetailsJim Storey
Joe Phone #: ###-#### defered to pm
BLD-Wall cover6/6/20196/6/20196/6/2019PPASS
DetailsJim Storey
vapor barrier exterior // Joe Phone #: ###-####/ pending architect submittal for wall protection
BLD-Energy code compliance6/4/20196/5/20196/5/2019APART
DetailsJim Storey
Joe- Phone #: ###-#### wall insulation ok/ need vappor barrior/ pending p/l fire wall aplacation at trusses.
BLD-Other5/16/20195/17/20195/20/2019APART
DetailsDave Hannah
fire wall // Joe Phone #: ###-#### sheet rock behind ledger ok
BLD-Wall Bracing4/30/20195/1/20195/1/2019AFAIL
DetailsJim Storey
Joe Phone #: ###-#### over driven renail
BLD-Framing/Rough-in4/30/20195/1/20195/1/2019AFAIL
DetailsJim Storey
Joe Phone #: ###-#### c/n 602 1 hr from bothsides provide engineering to resolve to planreview.
BLD-Other4/2/20194/3/20194/3/2019PPASS
DetailsDave Hannah
pre slab // Joe Phone #: ###-####
BLD-Footing3/18/20193/19/20193/19/2019PPASS
DetailsDave Hannah
pour time 3pm-Joe Phone #: ###-####
Issue PAID IN FULL permit  2/22/2019 DONE
Print Occupancy Form  2/22/2019 DONE
OVERRIDE  2/20/2019  
Plan assigned to (JG)10/12/201810/12/20182/20/2019 PASS
DetailsJavier Guzman
1st rev comp, 11/06 In The Bag Promotions Addition ePlan,
PLANS/APPL TAKEN TO FRONT DESK  2/20/2019 DONE
Permit Ready to Issue  2/20/2019 DONE
MET ashleyhaneborg@esi-express.com
Need
GC
Rev cert of val
RP
Routing - PLAN CHECK2/13/2019 2/20/2019 PASS
DetailsJavier Guzman
Routing PW Sewer Design2/13/2019 2/19/2019 PASS
DetailsDeAnn Brown
If for any reason the building addition cannot be plumbed into the existing sewer service line, Contact City of Boise Public Works for a tap permit to tap existing sewer main.
Routing - Design Review2/13/2019 2/13/2019 PASS
DetailsKatelyn Menuge
Okay-taller parapet at exterior east wall
Routing - FIRE2/5/20192/5/20192/11/2019 PASS
DetailsErika Akin
Attached comments to case
Routing - PLAN CHECK2/5/2019 2/6/2019 FAIL
DetailsJavier Guzman
Routing PW Drainage2/5/2019 2/6/2019 PASS
DetailsBrian Murphy
Routing PW Sewer Design2/5/2019 2/5/2019 FAIL
DetailsDeAnn Brown
Building addition plumbing plans show a sewer service exiting building on north side, but there are no submitted plans showing how the sewer service connects to the existing service line or directly to the sewer main in the roadway. Please include plans with this information.
Routing - Design Review2/5/2019 2/5/2019 PASS
DetailsKatelyn Menuge
Routing - PUBLIC WORKS2/5/2019 2/5/2019 PASS
DetailsMorgan Webb
Routing - FIRE1/8/20191/8/20191/23/2019 FAIL
DetailsErika Akin
Attached comments to case and emailed architect
Routing - PLUMBING1/17/2019 1/22/2019 PASS
DetailsDan Ediger
Per plans and ISPC
Routing - PLAN CHECK1/8/2019 1/18/2019 FAIL
DetailsJavier Guzman
Routing Off Site - STRUCTURAL1/8/2019 1/17/2019 PASS
DetailsJavier Guzman
signed off in ePlan by KPFF Cory Harelson

Routing PW Drainage1/8/2019 1/16/2019 FAIL
Routing PW Sewer Design1/8/2019 1/14/2019 FAIL
DetailsDeAnn Brown
Building addition plumbing plans show a sewer service exiting building on north side, but there are no submitted plans showing how the sewer service connects to the existing service line or directly to the sewer main in the roadway. Please include.
Routing - Design Review1/8/2019 1/10/2019 FAIL
DetailsKatelyn Menuge
Please update C1.0 to match changes made on SD1.1
Routing - PUBLIC WORKS1/8/2019 1/9/2019 PASS
DetailsMorgan Webb
Routing - Erosion and Sediment1/8/2019 1/9/2019 PASS
DetailsMichael Zawacki
Certified RP needed before construction activity begins.
Route to Impact Fee Review11/21/201811/24/201811/23/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE10/12/201810/12/201811/21/2018 FAIL
DetailsErika Akin
Attached comments to case and emailed architect
1st review completed  11/21/2018 DONE
Routing - PLAN CHECK10/12/2018 11/7/2018 FAIL
DetailsJavier Guzman
Routing Off Site - STRUCTURAL10/12/2018 11/5/2018 FAIL
DetailsJavier Guzman
Failed in ePlan by KPFF Cory Harelson

Routing PW Environmental10/12/2018 10/23/2018 PASS
DetailsRick Christenson
Routing PW Drainage10/12/2018 10/22/2018 FAIL
o of m appdx j system size, drainage report
Routing - MECHANICAL10/12/2018 10/16/2018 PASS
DetailsTroy James
Routing - PLUMBING10/12/2018 10/15/2018 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - Design Review10/12/2018 10/15/2018 FAIL
DetailsKatelyn Menuge
DRH18-00158 - See changemarks
Routing PW Sewer Design10/12/2018 10/15/2018 FAIL
DetailsDeAnn Brown
Submit site utility plan that shows connection to existing sewer system.
Routing PW Solid Waste10/12/2018 10/15/2018 PASS
DetailsEvan Carpenter
Routing - Erosion and Sediment10/12/2018 10/15/2018 FAIL
DetailsMichael Zawacki
No ESC narrative or BMP maps provided. Construction activity includes excavation and foundation and changing access and sidewalks.
Routing PW Street Lights10/12/2018 10/12/2018 PASS
DetailsTom Marshall
Routing - PLANNING10/12/2018 10/12/2018 PASS
DetailsNicolette Womack
CUP18-00051
Routing - Addressing10/12/2018 10/12/2018 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS10/12/2018 10/12/2018 PASS
DetailsMorgan Webb
Plans ACCEPTED BY PLAN TECH  10/10/2018 DONE
Recd Pcfee & Taken To Pln CK  10/10/2018 DONE
Intake Approval  10/10/2018 FAIL
DetailsJulie Romig
1) Electrical, Plumbing, and Mechanical values on Certificate of Value Page 5 of permit application.
2) Verification of Legal Lot or Parcel form with signed by subdivision planner.
3) Sheet M0.1 is too large to open. Reduce file size to less than and re-upload.
Intake Approval  10/10/2018 PASS
Application received  10/4/2018 DONE
Application submitted via PDS Online on Oct 4 2018 11:40AM
Third Notice 8/16/2020