Permit Information
Permit NumberBLD18-03923
StatusFinaled
Name PARKWAY C&A LP
Site Address 7499 W OVERLAND RD
Project NameHampton Inn and Suites Remodel
Customer NumberEARLY START BLD18-04155
ePlanReviewNo
Description
(HAMPTON INN AND SUITES REMODEL) // 06/10/19 PLAN MOD TO FIRE RATE THE LOBBY BEAM USING OPTION 2 (GA FILE BM1137) OR OPTION 3 (UL N759). JAR // 06/06/19 PLAN MOD TO REPAIR PORTE COCHERE ROOF DUE TO WATER DAMAGE. REPAIR TO MATCH ORIGINAL DESIGN AND TO BE CONSTRUCTED AS 1-HOUR FIRE RESISTANCE RATED ASSEMBLY WITH RATED PENETRATIONS. ALL RECESSED LIGHTS TO BE UL LISTED. JAR // This building is fire sprinklered. Permit for minor remodel to an existing hotel. Work to include: interior demo of office non-rated, non-bearing, partition walls; new interior non-rated, non-bearing partition walls and doors in office area; replacement of existing light fixtures with new LED fixtures; interior finishes including replacement of plumbing fixtures; new flooring and other new interior finishes in compliance with Ch. 8 of the 2015 IBC. Certificate of completion to be issued upon completion of work. **JAR**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Telephone call  3/9/2020 DONE
Left a message with Brandon about final values for electric
Meeting  3/3/2020 DONE
emailed chris to see if he has an idea of when fees may be paid
Telephone call  2/6/2020 DONE
Called Parkway for Final values. Receptionist said Chris not available but will call back. Gave address and permit #
Print Statement  1/22/2020 DONE
THIRD AND FINAL PAST DUE NOTICE
Print Statement  1/8/2020 DONE
Print Statement  12/10/2019 DONE
Second Notice 11/8/201911/26/2019 DONE
mailed 12-2-19
First Notice9/10/20199/10/201910/29/2019 DONE
DetailsMike Jordan
mailed 11-1
BLD-Final9/9/20199/10/20199/10/2019APASS
DetailsMike Jordan
Brandon Phone #: ###-####
DOC - Permit Finaled9/10/20199/10/20199/10/2019PPASS
DetailsMike Jordan
FIRE-Final Inspection9/4/20199/4/20199/4/2019PPASS
DetailsTroy Cobbley
Life safety passed. Card signed. Brandon Phone #: ###-####
BLD-Framing/Rough-in8/29/20198/30/20198/30/2019APASS
DetailsMike Jordan
Brandon Phone #: ###-####. Beyween noon and two. All issues regarding through penetrations for new tub drains has been resolved.
BLD-Conference8/28/20198/29/20198/29/2019ACANC
DetailsMike Jordan
Brandon Phone #: ###-####. Moved to friday 8-30.
BLD-Final7/25/20197/26/20197/26/2019APART
DetailsTell Riley
Brandon Phone #: ###-####//temp occupancy for offices behind lobby area//
FIRE-Final Inspection7/24/20197/25/20197/25/2019PPART
DetailsTroy Cobbley
Life safety is being given a partial for the remodeled office area behind the new check-in counter. Brandon Phone #: ###-####
BLD-Final7/24/20197/25/20197/25/2019APART
DetailsTell Riley
Brandon ###-####//need to verify with Troy for temp occupancy for lobby area only//ok for temp occupancy for reception area//do not occupy office areas and back room until all inspections complete//
BLD-Final7/23/20197/24/20197/24/2019PCANC
DetailsTell Riley
Brandon Phone #: ###-####
FIRE-Final Inspection7/24/20197/25/20197/24/2019APART
DetailsTroy Cobbley
Life safety is passed for the Lobby area but not the back office area. Per discussion emergency lighting will be required for the existing lobby prior to a final sign off just as it is being required at the bottom of both stairwells.

Brandon Phone #: ###-####
BLD-Ceiling Grid Inspection7/1/20197/2/20197/2/2019APASS
DetailsMike Jordan
Uri Phone #: ###-####
FIRE-Final Inspection7/2/20197/3/20197/2/2019ACANC
DetailsTroy Cobbley
cancel per Yuiry Yuriy Phone #: ###-####
BLD-Final7/2/20197/3/20197/2/2019PCANC
DetailsMike Jordan
cancel per Yuiry Yuriy Phone #: ###-####
BLD-Framing/Rough-in6/26/20196/26/20196/26/2019PPASS
DetailsMike Jordan
2 layers of 5/8 type X rock for previously unprotected beam ok for cover.
BLD-Framing/Rough-in6/25/20196/26/20196/26/2019PCANC
DetailsMike Jordan
yurry Phone #: ###-####.
Plan Reviewer's activity  6/21/2019 DONE
DetailsJulie Romig
Received email from owner that they will be removing the non-rated recessed Porte Cochere lights and replacing them with surface mounted lights to maintain the fire-resistance rated horizontal assembly. Installing rated access panel for electrical junction. All penetrations to comply with 2015 IBC 714.4. Work to be field verified by inspector.
BLD-Final6/19/20196/20/20196/20/2019PPART
DetailsMike Jordan
Yury-1st floor minus the front desk and back office Phone #: ###-####. Ok to occupy 1st. floor except for main lobby area.
FIRE-Final Inspection6/19/20196/20/20196/20/2019APART
DetailsTroy Cobbley
Life safety for the first floor, except for the Main Lobby and associated back office passed.

Yury-1st floor minus the front desk and back office Phone #: ###-####
BLD-Conference6/12/20196/13/20196/13/2019ADONE
DetailsMike Jordan
Eri Phone #: ###-####
Plan assigned to (JAR)6/7/20196/7/20196/11/2019 DONE
DetailsJulie Romig
06/13 - Plan Mod Hampton Inn Lobby Beam
Routing - PLAN CHECK6/7/2019 6/11/2019 PASS
DetailsJulie Romig
Permit Ready to Issue  6/11/2019 DONE
PLAN MOD
Inspection Record Card- Bld  6/11/2019 DONE
Telephone call  6/11/2019 DONE
Spoke with chris informing him that the plan mod is ready and the fee amount due
CHANGE STATUS TO (ISS)  6/11/2019 DONE
Permit Ready to Issue  6/7/2019  
PLAN MOD
Telephone call  6/7/2019 DONE
left a message for chris informing him that the plan modification is ready to be picked up and the fee amount due
Plan Modification Accepted  6/7/2019 DONE
2nd Plan mod for fire protection of unprotected beam. Plan application and 2 sets of documents. Taken to Julie
Routing - PLAN CHECK6/4/2019 6/6/2019 PASS
DetailsJulie Romig
Plan Modification Accepted  6/4/2019 DONE
This modification is to add in the needed repairs to the entry canopy, the canopy had a major roof leak and ruined most of the GYP sheathing causing the ceiling to start to collapse. We removed the damaged portion and would like to refinish the entry canopy back to it's original condition.
Plans stamped and taken to Reviewer
BLD-Framing/Rough-in5/30/20195/31/20195/31/2019AFAIL
DetailsJim Storey
Yurri Phone #: ###-#### II a const. beam in lobby unprotected. sub mit to planreview as to how to address.
BLD-Framing/Rough-in5/29/20195/30/20195/30/2019APART
DetailsMike Jordan
Jery Phone #: ###-####. Interior steel stud framed walls in lobby area only ok. Needs t patch sheetrock at floor ceiling assemblies and fircaulk all penetrations. A mech permit is also required for the new duct work that was added in drop down ceiling area. A plan mod or a seperate building permit is also required for the repair of the porte cochere. A correction notice was issued.
BLD-Framing/Rough-in5/23/20195/23/20195/24/2019PNR
DetailsDave Hannah
reception area // Yuri Phone #: ###-####
BLD-Conference4/29/20194/29/20194/29/2019PDONE
DetailsMike Jordan
The correct fire caulking on 1st. floor has now been used.
BLD-Conference4/29/20194/29/20194/29/2019AFAIL
DetailsMike Jordan
Noted that caulking used is a fire block and not a UL listed fire stop. Contractor to insatll correct materials and will reinspect this afternoon. A correction notice was also issued to fire stop all tub drains and plumbing penetrations for new lavs on the 3rd and 4th floors, to maintain the exisiting fire protection.
BLD-Conference4/25/20194/26/20194/26/2019ACANC
DetailsMike Jordan
BLD-Conference4/25/20194/25/20194/25/2019PDONE
DetailsMike Jordan
BLD-Final4/19/20194/24/20194/24/2019ACANC
DetailsMike Jordan
1st, 2nd and 3rd // Yuriy Phone #: ###-####
BLD-Conference4/24/20194/24/20194/24/2019ADONE
DetailsMike Jordan
1st, 2nd and 3rd // Yuriy Phone #: ###-####
BLD-Final4/17/20194/18/20194/18/2019PPART
DetailsMike Jordan
Steve Phone #: ###-####. OPK to occupy 2nf. floor.
BLD-Final4/16/20194/17/20194/17/2019PNR
DetailsMike Jordan
2nd floor // Steve Phone #: ###-####. Needs electrical final.
FIRE-Final Inspection4/16/20194/17/20194/17/2019APART
DetailsTroy Cobbley
Life safety for the 2nd floor passed.// Steve Phone #: ###-####
BLD-Final2/21/20192/22/20192/22/2019PPART
DetailsMike Jordan
3rd floor // Steve Phone #: ###-####. Ok to occupy 3rd floor.
FIRE-Final Inspection2/21/20192/22/20192/22/2019APART
DetailsTroy Cobbley
Temp for life safety on 3rd floor. Contractor had to remove the new LED bulbs from the emergency lights and re-install the old bulbs for them to work on battery back up. // Steve Phone #: ###-####
BLD-Final2/14/20192/15/20192/15/2019PPART
DetailsJim Sly
Steve- wants partial on the 4th floor for a temp c of o Phone #: ###-####
Temp OK for 4th floor ........Only.
FIRE-Final Inspection2/15/20192/15/20192/15/2019PPART
DetailsJim Page
Life fire safety inspection for level 4 complete. Stairwells to remain clear with no storage once TCO is authorized.
FIRE-Final Inspection2/14/20192/15/20192/15/2019AFAIL
DetailsJim Page
Left a voicemail with point of contact provided, waited for 30 minutes to recieve a return call, no return call was made, proceeded to next inspection, this request will need to be rescheduled.

Steve- wants partial on the 4th floor for a temp c of o Phone #: ###-####
Issue PAID IN FULL permit  12/6/2018 DONE
Inspection Record Card- Bld  12/6/2018 DONE
Meeting  12/5/2018 DONE
Emailed Chris, csauve@HMSID.COM, to verify the revised value is not including the early start/demo. he responded that he will double check with GC because he believes it does
Plan assigned to (JAR)10/25/201810/25/201812/4/2018 DONE
DetailsJulie Romig
12/03 - 2nd Rev - 1st Rev Comp - PAPER - L2 Hampton Hotel & Suites Interior Remodel
Case Summary (BLD)  12/4/2018 DONE
PLANS/APPL TAKEN TO FRONT DESK  12/4/2018 DONE
Permit Ready to Issue  12/4/2018 DONE
NEED CSAUVE@HMSID.COM-- ALL MET
CLOSE OUT BLD18-04155 (WHEN -03923 ISSUED)

MET
REVISED VALUE
GC FORM
Inspection Record Card- Bld  12/4/2018 DONE
Telephone call  12/4/2018 DONE
customer came in so didn't call-he will be back with the 302 & 306 filled out by the GC-we can give them the fees once we get that
Routing - FIRE11/27/201811/27/201812/3/2018 PASS
DetailsErika Akin
Attached comments to case
Routing - PLAN CHECK11/27/2018 11/29/2018 PASS
DetailsJulie Romig
Route to Impact Fee Review11/16/201811/19/201811/19/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
1st review completed  11/16/2018 FAIL
DetailsJulie Romig
Routing - PLAN CHECK  11/16/2018 FAIL
DetailsJulie Romig
Report emailed to architect.
Routing - FIRE 10/25/201811/15/2018 FAIL
DetailsErika Akin
Attached comments to case and emailed architect
Case Summary (BLD)  11/7/2018 DONE
Routing - PUBLIC WORKS  10/29/2018 PASS
Routing - PLUMBING10/29/2018 10/29/2018 PASS
DetailsDan Ediger
Per plans and ISPC
Routing - Addressing10/25/2018 10/26/2018 PASS
DetailsDoug Chausow
Plans ACCEPTED BY PLAN TECH  10/25/2018 DONE
Intake Approval  10/25/2018 PASS
DetailsJulie Romig
Recd Pcfee & Taken To Pln CK  10/25/2018 DONE
BLD-Conference8/15/20198/16/2019 A 
DetailsMike Jordan
Brandon Hout Phone #: ###-####
BLD-Conference4/26/20194/26/2019 P 
DetailsMike Jordan
Application received 10/25/2018