Information based on query as of Wednesday, November 18, 2026.
Permit Information
Permit NumberBLD18-04004
StatusFinaled
Name WRIGHT BROTHERS THE BLDG CO EAGLE
Site Address 350 N 9TH ST Unit: 100
Project NameJefferson Place Water Bear TI
Customer NumberBLD18-04317 DEMO
ePlanReviewYes
Description
(JEFFERSON PLACE) (WATER BEAR RESTAURANT TI) (SUITE 100) Permit for a 2,300 SF major tenant improvement for a new restaurant in Suite 100 of the existing 5-story Jefferson Place Building. Work to include: demolition of existing interior, non-structural partition walls and soffit; upgrading existing structural frame to 1-hour fire resistance rated construction; installation of new interior non-bearing partition walls; new ceiling and lighting; electrical; plumbing work for restrooms, kitchen, and bar; new mechanical ERV unit and ductwork; and interior finishes in compliance with Ch. 8 of the 2015 IBC. An alternate request was approved under BLD15-00476 for construction type change from IIIA to IIIB and requires protection of the primary structural frame with a 1-hour fire resistance rating in this tenant space. Pre-construction conference with building inspector required prior to coverage to verify rated construction. This building is fully Fire Sprinklered for additional story increase with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  11/14/2019 DONE
Print Statement  10/23/2019 DONE
Third Notice 8/10/20199/20/2019 DONE
mailed 9-23-19
Second Notice 7/20/20198/5/2019 DONE
mailed 8-6-19
First Notice 6/8/20197/10/2019 DONE
mailed 7-11
Permanent Occupancy  5/29/2019 DONE
BLD-Final5/2/20195/2/20195/2/2019PPASS
DetailsDave Hannah
Nicol Phone #: ###-#### ok for perm occ once MEC passes- per David H (MEC Final Complete 5/29/19 TCH)
FIRE-Final Inspection5/1/20195/2/20195/2/2019APASS
DetailsMark Scharfen
Verified extinguisher in place. Had verified Exit lights on 4/30. PASSED.

Nicol Phone #: ###-####
Temporary Occupancy5/2/20197/31/20195/2/2019 DONE
DetailsTiffany Carson-Herker
FIRE-Conference5/1/20195/1/20195/1/2019PDONE
DetailsTroy Cobbley
Per the general contractor a barrier is going to be installed above the cooler to provide separation.
FIRE-Final Inspection5/1/20195/1/20195/1/2019PCANC
DetailsJim Page
Nicol Phone #: ###-####
Nico canceled
BLD-Final5/1/20195/1/20195/1/2019PCANC
DetailsDave Hannah
Nicol Phone #: ###-####
Nico canceled
FIRE-Final Inspection4/30/20194/30/20194/30/2019PFAIL
DetailsMark Scharfen
Fire extinguishers are not installed will need to be on reinspection. Pocket door was noted and will be reviewed by building inspector.

Nicol Phone #: ###-####
BLD-Wall cover2/21/20192/22/20192/22/2019PPASS
DetailsDave Hannah
Nicol Phone #: ###-####
BLD-Conference2/5/20192/6/20192/6/2019APART
DetailsDave Hannah
Nicol Phone #: ###-#### to to rock top of walls
Print Occupancy Form  2/4/2019 DONE
Issue PAID IN FULL permit  2/4/2019 DONE
Permit Ready to Issue  2/1/2019 DONE
Met (jconrad@wbtbc.com)
(permit has never been issued before, resubmittals were submitted)
Plan assigned to (JAR)1/30/20191/30/20191/31/2019 DONE
DetailsJulie Romig
02/06 - 3rd Rev - 1st Rev Comp - Water Bear
Routing - PLAN CHECK1/31/2019 1/31/2019 PASS
DetailsJulie Romig
3rd Review - resubmittal of plans with rated assemblies
Plan resubmittals received  1/30/2019 DONE
Permit Ready to Issue  1/29/2019 DONE
Met
NEED
GC FORM
REVISED VALUE
Plan assigned to (JAR)11/21/201811/21/20181/28/2019 DONE
DetailsJulie Romig
1st Rev Comp - 2nd Rev Comp - L3 Water Bear
Routing - Design Review1/18/2019 1/28/2019 PASS
DetailsKayCee Babb
Per DRH18-00579.
Routing - PLAN CHECK1/28/2019 1/28/2019 PASS
DetailsJulie Romig
PLANS/APPL TAKEN TO FRONT DESK  1/28/2019 DONE
Routing - PLAN CHECK1/18/2019 1/25/2019 FAIL
DetailsJulie Romig
Routing - MECHANICAL1/18/2019 1/23/2019 PASS
DetailsTroy James
Route to Impact Fee Review12/13/201812/16/201812/13/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE11/21/201811/21/201812/13/2018 PASS
DetailsErika Akin
Attached comments to case
1st review completed  12/13/2018 FAIL
DetailsJulie Romig
Routing - Design Review12/12/2018 12/12/2018 FAIL
DetailsKayCee Babb
A Zoning Certificate is required for all exterior alterations, including proposed louvers.
Routing - PLAN CHECK11/21/2018 12/12/2018 FAIL
DetailsJulie Romig
Report emailed to architect.
Routing - PLUMBING12/5/2018 12/7/2018 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - PUBLIC WORKS12/6/2018 12/6/2018 PASS
DetailsMorgan Webb
Routing PW Environmental12/5/2018 12/6/2018 PASS
DetailsTerry Alber
Endura grease trap shown on triple sink. Dish washer not allowed to discharge to grease trap.
Routing - MECHANICAL11/21/2018 11/28/2018 FAIL
DetailsTroy James
Need hood over the dishwashers.
Routing - PLUMBING11/21/2018 11/27/2018 FAIL
DetailsDaryl Spivey
Resubmit with PW's required grease abatement on plumbing.
Routing - Addressing11/21/2018 11/26/2018 PASS
DetailsDoug Chausow
Routing PW Environmental11/21/2018 11/26/2018 FAIL
DetailsTerry Alber
No grease abatement shown. Kitchen must have "suitable and adequate" grease abatement prior to discharging to basement sewer injector system.
Routing - PLANNING11/21/2018 11/23/2018 PASS
DetailsNicolette Womack
Routing - PUBLIC WORKS11/21/2018 11/21/2018 PASS
DetailsMorgan Webb
Plan Reviewer's activity  11/19/2018 PASS
Plan Intake Review approved
Intake Approval  11/19/2018 PASS
Application received  11/1/2018 DONE
Application submitted via PDS Online on Nov 1 2018 9:44PM