Permit NumberBLD18-04088
StatusFinaled
Name YMC INC
Site Address 3201 W AIRPORT WAY
Project NameBOI - CBRA Room HVAC Upgrade
Customer Number 
ePlanReviewYes
Description
(BOI – BOISE CITY AIR TERMINAL) The building fire sprinkler system is used for fire area. To perform upgrades to the HVAC system that serves the CBRA (Check Baggage Reconciliation Area) Room. No new mechanical rooftop equipment is approved under this permit. Work is completely within the interior of the mezzanine above the Out-Going Make-Up Baggage Area (Room #142B) on the 1st story. NO EXTERIOR WORK. The work is required to comply with the approved drawings and with all applicable codes and ordinances. This is a scope of work permit only and does not establish a Certificate of Occupancy for any portion of this building. This building already has a Certificate of Occupancy. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained for any modification to the systems as a result of this work. **JHB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 6/20/20196/25/2019 DONE
This permit finaled on the web by Rhonda Marcum
First Notice5/22/20195/22/20196/10/2019 DONE
DetailsJim Storey
mailed 6-11
BLD-Final5/21/20195/22/20195/22/2019PPASS
DetailsJim Storey
Please call Dan at least 30 min prior to inspection, thank you. Phone #: ###-#### Inspection requested via web by Rhonda Marcum
DOC - Permit Finaled5/22/20195/22/20195/22/2019PPASS
DetailsJim Storey
FIRE-Final Inspection5/21/20195/22/20195/22/2019APASS
DetailsTroy Cobbley
Life safety passed.

Please call Dan at least 30 min prior to inspection, thank you. Phone #: ###-#### Inspection requested via web by Rhonda Marcum
BLD-Final5/21/20195/21/20195/21/2019PNR
DetailsJim Storey
Please call Dan at least 30 min prior to inspection, thank you. Phone #: ###-#### Inspection requested via web by Rhonda Marcum need fire insp.
Issue PAID IN FULL permit  5/6/2019 DONE
Inspection Record Card- Bld  5/6/2019 DONE
Telephone call  5/3/2019 DONE
emailed the remaining fees due to- bgraham@ymcins.com, Danny Hamilton & Jill Singer
Meeting  4/30/2019 DONE
sent email to david informing permit is going to expire in 7 days.
Expiration Notice4/15/20195/6/20194/15/2019 DONE
DetailsBrittany Hill
Plan assigned to (JHB)11/15/201811/15/201812/6/2018 PASS
DetailsJoe Bruce
*(1st Rev Comp)12/03 (L2) - CBRA Room HVAC Improvement (DR, Bldg)
Routing - PLAN CHECK12/4/2018 12/6/2018 PASS
DetailsJoe Bruce
Exterior mechanical exhaust rooftop unit was removed from the scope of this project. **JHB**
Routing - MECHANICAL12/6/2018 12/6/2018 PASS
DetailsChad Schwendiman
PLANS/APPL TAKEN TO FRONT DESK  12/6/2018 DONE
Permit Ready to Issue  12/6/2018 DONE
(need JV account if GC is not paying fee)

MET- Need
GC Form
Revised Cert of Value
Routing - Design Review12/4/2018 12/5/2018 PASS
DetailsKayCee Babb
No Design Review required due to exterior alterations being removed from scope.
Plan resubmittals received  12/4/2018 DONE
DetailsJoe Bruce
Received resubmittal in ePlan. Applicant has removed the rooftop exhaust fan from the scope. **JHB**
Route to Impact Fee Review11/29/201812/2/201811/30/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - PLAN CHECK11/15/2018 11/29/2018 FAIL
DetailsJoe Bruce
1st review completed  11/29/2018 FAIL
DetailsJoe Bruce
Plan resubmittals requested  11/29/2018 DONE
DetailsJoe Bruce
Routed ePlan task back to applicant. **JHB**
Routing - MECHANICAL11/15/2018 11/23/2018 PASS
DetailsChad Schwendiman
Routing - Design Review11/15/2018 11/15/2018 FAIL
DetailsKayCee Babb
A Zoning Certificate is required for the proposed project due to the equipment exceeding the height of the existing parapet.
Intake Approval  11/14/2018 PASS
DetailsJoe Bruce
Application received  11/8/2018 DONE
Application submitted via PDS Online on Nov 8 2018 9:52AM
Intake Approval  11/8/2018 FAIL
DetailsJoe Bruce
1) The incorrect mechanical code is listed on sheet G0.1. The currently adopted mechanical code is the 2012 version. Update the cover sheet to the correct code cycle.