BLD-Blower Door Test Results | 8/1/2019 | 8/1/2019 | 8/1/2019 | A | DONE |
Tell Riley
|
|
|
4.29 ACH 50
1263 CFM @ 50 pa
|
BLD-Final | 7/31/2019 | 8/1/2019 | 8/1/2019 | A | PASS |
Tell Riley
|
|
|
Larry Phone #: ###-####//corrections made//final complete//
|
DOC - Permit Finaled | 8/1/2019 | 8/1/2019 | 8/1/2019 | P | PASS |
Tell Riley
|
|
|
|
BLD-Final | 7/29/2019 | 7/30/2019 | 7/30/2019 | A | FAIL |
Tell Riley
|
|
|
Larry Phone #: ###-####//need to add smoke detector and smoke carbon combo per plans//
|
BLD-Energy code compliance | 3/18/2019 | 3/19/2019 | 3/19/2019 | A | PASS |
Jim Sly
|
|
|
Phone #: ###-####
|
BLD-Framing/Rough-in | 3/14/2019 | 3/15/2019 | 3/15/2019 | A | PART |
Tony Young
|
|
|
Larry Phone #: ###-####,, brace gables per engineering,, ok to insulate
|
Routing - MECHANICAL | 3/6/2019 | | 3/6/2019 | | PASS |
Troy James
|
|
|
Resubmitted manual j report
|
BLD-Wall Bracing | 2/13/2019 | 2/13/2019 | 2/13/2019 | P | PASS |
Tony Young
|
|
|
Larry Phone #: ###-####
|
BLD-Wall Bracing | 12/28/2018 | 12/28/2018 | 12/28/2018 | P | PART |
Tony Young
|
|
|
Javier Phone #: ###-####,, foundation ok,, work in progress
|
BLD-Footing | 12/27/2018 | 12/27/2018 | 12/27/2018 | P | PASS |
Tony Young
|
|
|
Edgar Phone #: ###-####
|
Issue PAID IN FULL permit | | | 12/20/2018 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 12/20/2018 | | DONE |
|
|
|
|
Routing - FIRE | 12/12/2018 | 12/12/2018 | 12/12/2018 | | PASS |
Lee G Meredith
|
|
|
New SFH
An NFPA 13D fire sprinkler system is required to be installed per PUD16-00029.
|
CHANGE STATUS TO (REV) | | | 12/12/2018 | | DONE |
|
|
|
Needed to go through fire review. Please see Leon or Michael for questions
|
CHANGE STATUS TO (RDY) | | | 12/12/2018 | | DONE |
|
|
|
|
Routing - PLANNING | 11/15/2018 | | 12/12/2018 | | FAIL |
Leon Letson
|
|
|
Fire sprinklers required per PUD16-00029.
|
Place hold on job | 12/12/2018 | | 12/12/2018 | | DONE |
Brittany Hill
|
|
|
make sure permit went through review for fire before issuance
|
OVERRIDE | | | 11/27/2018 | | |
|
|
|
|
1st review completed | | | 11/27/2018 | | DONE |
Michael Hanson
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/27/2018 | | DONE |
Michael Hanson
|
|
|
|
Permit Ready to Issue | | | 11/27/2018 | | DONE |
|
|
|
DO NOT ISSUE PER LEON. THIS SHOULD HAVE GONE THROUGH FIRE REVIEW, HOME IS REUIRED TO BE FIRE SPRINKLE. HE WILL SPEAK WITH MICHAEL
|
Plan assigned to (M_H) | 11/15/2018 | | 11/27/2018 | | DONE |
Michael Hanson
|
|
|
11/28 #402 L1 ePlan
|
Routing - PLAN CHECK | 11/15/2018 | | 11/27/2018 | | PASS |
Michael Hanson
|
|
|
|
Route to Impact Fee Review | 11/15/2018 | 11/18/2018 | 11/19/2018 | | PASS |
Eric Bilimoria
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - MECHANICAL | 11/15/2018 | | 11/19/2018 | | PASS |
Troy James
|
|
|
|
Routing - PUBLIC WORKS | 11/15/2018 | | 11/16/2018 | | PASS |
Angela Hardy
|
|
|
|
Application received | | | 11/15/2018 | | DONE |
|
|
|
Application submitted via PDS Online on Nov 15 2018 12:29PM
|
Plans ACCEPTED BY PLAN TECH | | | 11/15/2018 | | DONE |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 11/15/2018 | | DONE |
|
|
|
|
Intake Approval | | | 11/15/2018 | | PASS |
|
|
|
|
Routing - Addressing | 11/15/2018 | | 11/15/2018 | | PASS |
Doug Chausow
|
|
|
Address: 2470 N Birchgrove Ln
|