Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD18-04462
StatusFinaled
Name WOOD RIVER BUILDERS
Site Address 131 E DEMMING LN
Project Name131 DEMMING
Customer Number 
ePlanReviewYes
Description
**PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 1977 sq. ft., two story (first story 1041 sq. ft., second story 936 sq. ft.) single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 120 sq. ft. of covered patio/porch and a 420 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/10/20197/11/20197/11/2019APASS
DetailsBrandon Shaw
Bobby Phone #: ###-####
DOC - Permit Finaled7/11/20197/11/20197/11/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results7/11/20197/11/20197/11/2019ADONE
DetailsBrandon Shaw
ACH50- 3.82
BLD-Final7/8/20197/9/20197/9/2019AFAIL
DetailsBrandon Shaw
Post blower door test results...
BLD-Energy code compliance4/12/20194/12/20194/12/2019PPASS
DetailsJim Storey
Bobby Phone #: ###-####
BLD-Other4/10/20194/11/20194/11/2019APASS
DetailsJim Storey
fire rated soffit // Bobby Phone #: ###-####
BLD-Energy code compliance4/10/20194/11/20194/11/2019AFAIL
DetailsJim Storey
Bobby Phone #: ###-#### no depth indcator/ no access back bed rm.
BLD-Energy code compliance4/9/20194/10/20194/10/2019PNR
DetailsJim Storey
Todd Phone #: ###-####
BLD-Framing/Rough-in4/8/20194/9/20194/9/2019APASS
DetailsJim Storey
Todd Phone #: ###-####
BLD-Wall Bracing3/21/20193/22/20193/22/2019APASS
DetailsBrandon Shaw
Work in progress...
BLD-Footing2/21/20192/22/20192/22/2019PPASS
DetailsJim Storey
Matt Phone #: ###-####
BLD-Footing2/20/20192/20/20192/20/2019PCANC
DetailsJim Storey
Matt Phone #: ###-####
BLD-Footing2/19/20192/19/20192/19/2019PNR
DetailsMike Jordan
Matt Phone #: ###-####
BLD-Footing2/11/20192/12/20192/12/2019ACANC
DetailsBrandon Shaw
Matt Phone #: ###-####
Issue PAID IN FULL permit  1/15/2019 DONE
Inspection Record Card- Bld  1/15/2019 DONE
OVERRIDE  12/19/2018  
Plan assigned to (J_N)12/14/201812/14/201812/19/2018 DONE
DetailsJenny Nelson
12/27 sfd L1 ePlan. 1st review, beam doesn't match structural calculations
Routing - PLAN CHECK12/19/2018 12/19/2018 PASS
DetailsJenny Nelson
PLANS/APPL TAKEN TO FRONT DESK  12/19/2018 DONE
DetailsJenny Nelson
Permit Ready to Issue  12/19/2018 DONE
met
Routing - Addressing12/14/2018 12/18/2018 PASS
DetailsLaura Hunter
1st review completed  12/18/2018 FAIL
DetailsJenny Nelson
Routing - PLAN CHECK12/14/2018 12/18/2018 FAIL
DetailsJenny Nelson
Beam doesn't match structural calculations
Route to Impact Fee Review12/14/201812/17/201812/17/2018 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL12/14/2018 12/17/2018 PASS
DetailsTroy James
Routing - PLANNING12/14/2018 12/17/2018 PASS
DetailsSue Cummings
Routing - PUBLIC WORKS12/14/2018 12/17/2018 PASS
DetailsAngela Hardy
Application received  12/14/2018 DONE
Application submitted via PDS Online on Dec 14 2018 3:22PM
Plans ACCEPTED BY PLAN TECH  12/14/2018 DONE
Intake Approval  12/14/2018 PASS
Recd Pcfee & Taken To Pln CK  12/14/2018 DONE