Permit Information
Permit NumberBLD19-00125
StatusFinaled
Name PRUETT CONSTRUCTION LLC
Site Address 4503 W IRVING ST
Project NamePassmore Addition
Customer Number 
ePlanReviewYes
Description
Permit for a 1,496sq' two-story addtion and full structural remodel of the existing home. Final layout is 4bd/2bth. All work per plans, notations, local codes & ordinances. Separate electrical, plumbing & mechanical permits required. **JAB**
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/23/201910/24/201910/24/2019APASS
DetailsTell Riley
Please call before. Phone #: ###-#### Inspection requested via web by Vaughn Pruett//approved plans provided//corrections made//upper kitchen moved to interior wall--only difference on plans//final complete per approved plans//
DOC - Permit Finaled10/24/201910/24/201910/24/2019PPASS
DetailsTell Riley
BLD-Final10/17/201910/18/201910/18/2019AFAIL
DetailsTell Riley
Please call before Phone #: ###-#### Inspection requested via web by Vaughn Pruett//correction notice issued//several items noted for code compliance//will need plans onsite for final as well//
BLD-Energy code compliance7/17/20197/17/20197/17/2019PPART
DetailsTell Riley
Vaughn Phone #: ###-####//corrections made//designer printed new shear page--CS14 straps not needed//add insulation to wall between garage utility//
BLD-Framing/Rough-in7/12/20197/15/20197/15/2019APASS
DetailsTell Riley
Vaughn Phone #: ###-####//trusses ok//hold downs ok//add straps for shear walls per plans//ok to insulate only//
BLD-Framing/Rough-in7/11/20197/12/20197/12/2019AFAIL
DetailsTell Riley
Vaugh Phone #: ###-####//add straps per plans//HDU anchors need 5" in concrete//need truss plans//correction notice posted..//
Override - Parcel Holds7/11/20191/1/19007/11/2019  
this is not the final so insp ok
Routing - MECHANICAL7/8/2019 7/8/2019 PASS
DetailsTroy James
Manual j report. Back up heat source is a pellet stove and gas fireplace.
BLD-Wall Bracing6/10/20196/11/20196/11/2019AFAIL
DetailsTell Riley
Vaughan Pruett Phone #: ###-####// no hold downs installed// obtain retro from designer for hold down install. call for re inspection.// ok to install house wrap. nailing ok per plans
BLD-Foundation5/1/20195/2/20195/2/2019PPASS
DetailsJim Sly
Dustin-stem wall Phone #: ###-####
BLD-Footing4/26/20194/29/20194/29/2019APASS
DetailsJim Sly
Dustin Phone #: ###-####
Issue PAID IN FULL permit  4/16/2019 DONE
Inspection Record Card- Bld  4/16/2019 DONE
Plan assigned to (JAB) Josh1/16/20191/16/20193/27/2019 PASS
DetailsJosh Bogle
1/21 remodel, ePlan - 1st done
Routing - PLAN CHECK3/27/2019 3/27/2019 PASS
DetailsJosh Bogle
PLANS/APPL TAKEN TO FRONT DESK  3/27/2019 DONE
DetailsJosh Bogle
ESC yes - Energy yes
Permit Ready to Issue  3/27/2019 DONE
NEED
RP
Routing - PLANNING3/26/2019 3/26/2019 PASS
DetailsSue Cummings
O.K. now
Plan Reviewer's activity  3/26/2019 DONE
DetailsJosh Bogle
left msg for Vaughn asking about beam sizes - plans may have a glitch that is making them illegible
Routing - PLANNING3/14/2019 3/14/2019 FAIL
DetailsSue Cummings
ROS #11731 combines the percels into one. Back up area concrete need to be 3 ft. from PL
Routing - PLAN CHECK3/14/2019 3/14/2019 FAIL
DetailsJosh Bogle
beams innadequate
Routing - PLANNING2/14/2019 2/15/2019 FAIL
DetailsSue Cummings
The ROS has not yet been completed. Needs to show approach the new garage
Routing - PLAN CHECK2/14/2019 2/15/2019 FAIL
DetailsJosh Bogle
see e-mail 2.15.19
Plan Reviewer's activity  2/14/2019 DONE
DetailsJosh Bogle
accepted resubmittal - inquired with LTL about ROS
1st review completed  1/16/2019 FAIL
DetailsJosh Bogle
Routing - PLAN CHECK1/15/2019 1/16/2019 FAIL
DetailsJosh Bogle
see e-mail to Vaughn 1.16.19
Intake Approval  1/15/2019 PASS
Intake Approval  1/14/2019 FAIL
Site plan must include both parcels with set backs. The current site plan implies the new addition encroaches on unknown property. Also, make sure that the setback distances import clearly and are readable.
Intake Approval  1/11/2019 FAIL
Please upload all plan sheets individually
Application received  1/10/2019 DONE
Application submitted via PDS Online on Jan 10 2019 5:27PM
Routing - PLANNING1/16/2019   FAIL
Two kitchens are not allowed.