BLD-Final | 7/24/2019 | 7/25/2019 | 7/25/2019 | A | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick
|
DOC - Permit Finaled | 7/25/2019 | 7/25/2019 | 7/25/2019 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Blower Door Test Results | 7/25/2019 | 7/25/2019 | 7/25/2019 | A | DONE |
Brandon Shaw
|
|
|
ACH50- 3.86
|
PubWorks Occupancy Approval | 7/25/2019 | 7/25/2019 | 7/25/2019 | | DONE |
Melissa Jannusch
|
|
|
A letter from the applicant’s civil engineer indicating that the final grading and drainage is acceptable has been received by Public Works. Final occupancy may be approved by the building department. Melissa Jannusch ###-####.
|
BLD-Energy code compliance | 4/23/2019 | 4/23/2019 | 4/23/2019 | P | PASS |
Brandon Shaw
|
|
|
Corrections SAT...
|
BLD-Framing/Rough-in | 4/22/2019 | 4/22/2019 | 4/22/2019 | P | FAIL |
Jim Storey
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick truss rep to supply sign off a1 out of plmb// a13 web brace/ hvac cut out king stud overspacing for bearing wall.
|
BLD-Other | 4/22/2019 | 4/22/2019 | 4/22/2019 | P | PASS |
Jim Storey
|
|
|
Soffit please Phone #: ###-#### Inspection requested via web by Kyle Seick
|
BLD-Wall Bracing | 3/28/2019 | 3/29/2019 | 3/29/2019 | A | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick
|
BLD-Foundation | 3/12/2019 | 3/12/2019 | 3/12/2019 | P | PASS |
Brandon Shaw
|
|
|
Work in progress...
|
BLD-Foundation | 3/11/2019 | 3/12/2019 | 3/12/2019 | A | CANC |
Brandon Shaw
|
|
|
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell Inspection cancelled from web by: Kyle Seick
|
BLD-Foundation | 3/11/2019 | 3/12/2019 | 3/11/2019 | A | CANC |
Brandon Shaw
|
|
|
Phone #: ###-#### >> Inspection requested via web by Kyle Seick Inspection cancelled via mobile web on Monday, March 11, 2019.
|
BLD-Foundation | 3/10/2019 | 3/11/2019 | 3/11/2019 | A | FAIL |
Mike Jordan
|
|
|
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell. Reinforcement not per plan.
|
BLD-Conference | 3/10/2019 | 3/11/2019 | 3/10/2019 | A | CANC |
Brandon Shaw
|
|
|
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell Inspection cancelled via mobile web on Sunday, March 10, 2019.
|
BLD-Footing | 3/8/2019 | 3/8/2019 | 3/9/2019 | P | PASS |
Jim Sly
|
|
|
Edgar Phone #: ###-####
|
PubWorks Subgrade Approval | 3/6/2019 | 3/6/2019 | 3/6/2019 | | DONE |
Melissa Jannusch
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Melissa Jannusch ###-####.
|
Issue PAID IN FULL permit | | | 2/15/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 2/15/2019 | | DONE |
|
|
|
|
OVERRIDE | | | 2/7/2019 | | |
|
|
|
|
Plan assigned to (RDP) | 1/30/2019 | 1/30/2019 | 2/7/2019 | | DONE |
Rob Patrick
|
|
|
02/13 sfd L2 ePlan...1st Complete. Failed for Braced wall
|
Routing - PLAN CHECK | 1/30/2019 | | 2/7/2019 | | FAIL |
Rob Patrick
|
|
|
Need Braced Wall Materials
|
1st review completed | | | 2/7/2019 | | FAIL |
Rob Patrick
|
|
|
|
Routing - PLAN CHECK | 2/7/2019 | | 2/7/2019 | | PASS |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 2/7/2019 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 2/7/2019 | | DONE |
|
|
|
met
|
Routing - PLANNING | 1/25/2019 | | 2/6/2019 | | PASS |
Sue Cummings
|
|
|
|
Plan assigned to (BJM) | 1/25/2019 | 1/25/2019 | 1/30/2019 | | DEFR |
Brian McGowan
|
|
|
02/13 sfd L2 ePlan
|
Route to Impact Fee Review | 1/25/2019 | 1/28/2019 | 1/28/2019 | | PASS |
Shannon Cade
|
|
|
Initial residential review of new SFD permits requested for now.
Impact fees assessed at $2,562.37 are correct for the North River area of impact. SLC
|
Routing - Erosion and Sediment | 1/25/2019 | | 1/28/2019 | | PASS |
Michael Zawacki
|
|
|
Foothills sub, site prep inspection required.
|
Routing PW Grading-Hillside | 1/25/2019 | | 1/28/2019 | | PASS |
Melissa Jannusch
|
|
|
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at ###-#### with questions.
Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at ###-####.
The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.
|
Routing - FIRE | 1/25/2019 | 1/25/2019 | 1/25/2019 | | PASS |
Lee G Meredith
|
|
|
No Sprinklers Required.
|
Routing - Addressing | 1/25/2019 | | 1/25/2019 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 1/25/2019 | | 1/25/2019 | | PASS |
Morgan Webb
|
|
|
|
Routing - MECHANICAL | 1/25/2019 | | 1/25/2019 | | PASS |
Troy James
|
|
|
|
Intake Approval | | | 1/25/2019 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 1/25/2019 | | DONE |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 1/25/2019 | | DONE |
|
|
|
|
Application received | | | 1/24/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Jan 24 2019 9:47AM
|