Permit Information
Permit NumberBLD19-00475
StatusFinaled
Name CARROLL CONSTRUCTION
Site Address 407 W BANNOCK ST Unit: 100
Project NameEdwards Jones - Suite #100
Customer NumberDEMO BLD19-00600,BLD19-00476 &00477
ePlanReviewYes
Description
(EDWARD JONES – RADAR BLDG - MAIN FLOOR SUITE #100) // 7-10-2019 PLAN MODIFICATION TO ADD NEW TENANT EDWARD JONES TO SUITE #100, FLOOR PLAN AND ELECTRICAL WORK MODIFICATIONS. JG// (An Interior non-structural demo permit was issued under BLD19-00600) Permit is to remodel an existing 1,502 sq. ft. business space and related exterior site work. Approval is contingent upon adhering to the approved plans on file, plan review report and attached engineering. Work to include: removal of concrete sidewalk, exterior awnings, removal of exterior concrete basement and main floor entry stairs/landings/retaining wall/guards and handrails, back fill rear area at removed stairs/retaining wall, removal of select exterior walls, removal of roof assembly, removal of interior stairs and infill floor opening, removal of interior bearing and nonbearing walls, removal of exterior and interior door/door frames, removal of chimney and infill floor opening, removal of select raised floor, removal of exterior windows, removal of gypsum ceiling, removal of millwork, removal of plumbing fixtures, new exterior concrete sidewalk, construction of new exterior concrete front entry stairs/landings and a retaining walls with guards and handrails, new exterior front and rear awnings, new unenclosed vertical platform lift, select new structural roof support at new RTU’s, new roof assembly with spray-in cell foam insulation, construction of interior bearing and non-bearing walls to create an conference room, an office, (3) open office areas, a reception area, a break/work area and an accessible restroom, new interior furred at the exterior envelope walls with insulation, new exterior windows, new door/door frames, new exterior storefront entry door, new select wall infill at old exterior wall door opening, millwork, new gypsum and suspended acoustic ceiling, light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. Note: special inspection required, see 310 form. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice 7/27/20198/5/2019 DONE
mailed 8-5-2019
Permanent Occupancy  7/17/2019 DONE
BLD-Final7/16/20197/16/20197/16/2019PPASS
DetailsDave Hannah
Armando Phone #: ###-####
BLD-Final7/15/20197/16/20197/16/2019APEND
DetailsDave Hannah
Armando Phone #: ###-####
Zoning Approval7/16/20197/16/20197/16/2019 PASS
DetailsKayCee Babb
FIRE-Final Inspection7/15/20197/15/20197/15/2019PPASS
DetailsJim Page
No fire sprinklers, no fire alarms, fire extinguisher is placed with a current inspection tag. Final life fire safety inspection for area of work complete.

Armando Phone #: ###-####
Zoning Approval7/15/20197/15/20197/15/2019 FAIL
DetailsKayCee Babb
Accessible parking sign needs to be removed from non accessible parking stall and relocated to newly painted accesible parking stall to meet ADA requirements.
OVERRIDE  7/12/2019  
Print Occupancy Form  7/12/2019 DONE
plan mod
CHANGE STATUS TO (ISS)  7/12/2019 DONE
plan mod
Permit Ready to Issue  7/12/2019 DONE
DO NOT ISSUE plan mod accepted
Plan assigned to (JG)7/8/20197/8/20197/11/2019 PASS
DetailsJavier Guzman
Plan Mod VANILLA – RADAR BLDG ePlan
Routing - PLAN CHECK7/10/2019 7/11/2019 PASS
DetailsJavier Guzman
Plan Reviewer's activity  7/11/2019 DONE
DetailsJavier Guzman
Per Architect phone conversation on 7/11/2019 this new opening #2 already had an existing beam header over the new reconstructed wall. This area of the new framed opening #2 is not load bearing per architect Matt Rhees
Routing - PUBLIC WORKS7/10/2019 7/10/2019 PASS
DetailsAngela Hardy
FIRE-Final Inspection7/9/20197/9/20197/9/2019PCANC
DetailsJim Page
As of these notes the permit status is under review for floor plan modifications, floor plan needs to match city approved drawings for life fire safety inspection, need permit to be in issued status for life fire safety inspection to be completed, this request is cancelled and a new inspection will need to be requested when permit is back in issued status.

Armodo Phone #: ###-####
Plan Modification Accepted  7/8/2019 DONE
minor floor plan modification
BLD-Ceiling Grid Inspection7/1/20197/2/20197/2/2019APASS
DetailsDave Hannah
Armando Phone #: ###-####
BLD-Other5/30/20195/31/20195/31/2019ADEFR
DetailsDave Hannah
welding // almondo Phone #: ###-#### needs spec insp
BLD-Concrete5/22/20195/23/20195/23/2019ADONE
DetailsDave Hannah
Armando Phone #: ###-####
BLD-Energy code compliance5/8/20195/8/20195/9/2019PPASS
DetailsDave Hannah
after 2 // Armando Phone #: ###-####
BLD-Framing/Rough-in4/11/20194/12/20194/12/2019APASS
DetailsDave Hannah
Ken Phone #: ###-####
BLD-Conference3/22/20193/25/20193/25/2019ADONE
DetailsDave Hannah
Ken Phone #: ###-####
Route to Impact Fee Review3/14/20193/17/20193/15/2019 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Issue PAID IN FULL permit  3/15/2019 DONE
Inspection Record Card- Bld  3/15/2019 DONE
OVERRIDE  3/14/2019  
Plan assigned to (JG)2/22/20192/22/20193/14/2019 PASS
DetailsJavier Guzman
1st rev comp, 3/13 (L3) Radar Building - Shell & 1st Flr Vanilla TI, ePlan
Routing - PLAN CHECK2/22/2019 3/14/2019 PASS
DetailsJavier Guzman
1st review completed  3/14/2019 FAIL
DetailsJavier Guzman
Routing - Design Review3/14/2019 3/14/2019 PASS
DetailsKayCee Babb
Per CZC19-00016, as updated 3-11-19.
Routing - PLAN CHECK3/14/2019 3/14/2019 PASS
DetailsJavier Guzman
Routing Off Site - STRUCTURAL3/14/2019 3/14/2019 PASS
DetailsJavier Guzman
Detail 12 on A4.0 shows the plate being 3"x3" but the callout is a 4"x4" plate. According to the calculations the the anchor bolt spacing is to be 3" on center. It appears that the 3" dimension shown in detail 12 on A4.0 should be to the anchor bolts and not the end of the base plate. Please verify.
Revised detail 12 on plan sheet A4.0 showed the base plate being 4” x 4” with the pre drilled holes at 3” on center according to outsource engineers changemark request. Plans were not resent to outsource.
(engineers chagemark stated the following “Detail 12 on A4.0 shows the plate being 3"x3" but the callout is a 4"x4" plate. According to the calculations the the anchor bolt spacing is to be 3" on center. It appears that the 3" dimension shown in detail 12 on A4.0 should be to the anchor bolts and not the end of the base plate. Please verify.” )
PLANS/APPL TAKEN TO FRONT DESK  3/14/2019 DONE
Permit Ready to Issue  3/14/2019 DONE
NEED
REVISED VALUE
RP
Routing Off Site - STRUCTURAL2/22/2019 3/13/2019 FAIL
DetailsJavier Guzman
failed in ePlan by AHJ Engineers Chris Holladay

Routing - Erosion and Sediment2/22/2019 3/11/2019 PASS
DetailsAndy J. Long
ESC plan waiver request approved. Need to designate who the onsite ESC Responsble Person will be.
Routing - MECHANICAL2/22/2019 2/27/2019 PASS
DetailsTroy James
Permit for exterior work only
Routing - PLUMBING2/22/2019 2/22/2019 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - Addressing2/22/2019 2/22/2019 PASS
DetailsDoug Chausow
Suite 100
Routing - PUBLIC WORKS2/22/2019 2/22/2019 PASS
DetailsAngela Hardy
Routing - Design Review2/22/2019 2/22/2019 FAIL
DetailsKayCee Babb
Submitted plans vary from those approved through CZC19-00016. Elevations differ and rooftop mechanical equipment was never reviewed. Applicant needs to provide Design Review Staff with updated drawings and equipment details for review.
Intake Approval  2/22/2019 PASS
DetailsBrian McGowan
Prescreen approved by Brian McGowan.
Intake Approval  2/19/2019 FAIL
DetailsBrian McGowan
In order to finish processing the Prescreen please resolve the following:
1. The Engineer's designs on the Architectural Sheets need to have the Engineer's stamp and signature.

Thank you,
Application received  2/15/2019 DONE
Application submitted via PDS Online on Feb 15 2019 4:42PM