BLD-Final | 8/6/2020 | 8/6/2020 | 8/6/2020 | P | PASS |
Jim Storey
|
|
|
Screened- call for access Tyler Phone #: ###-####
|
DOC - Permit Finaled | 8/6/2020 | 8/6/2020 | 8/6/2020 | P | PASS |
Jim Storey
|
|
|
|
BLD-Framing/Rough-in | 6/16/2020 | 6/17/2020 | 6/17/2020 | A | PASS |
Jim Storey
|
|
|
Tyler *screened* Phone #: ###-####
|
BLD-Wall Bracing | 5/28/2020 | 5/28/2020 | 5/28/2020 | P | PASS |
Jim Storey
|
|
|
Shear inspection garage. Fire wall and truss engineering complete. Drywaller will hang two layers below when dried in. Phone #: ###-#### Inspection requested via web by Tyler Hildebrand nail hanger to truss
|
BLD-Energy code compliance | 5/26/2020 | 5/26/2020 | 5/26/2020 | P | PASS |
Tony Young
|
|
|
Tyler Phone #: ###-####,, seal pack ok also
|
BLD-Framing/Rough-in | 5/21/2020 | 5/21/2020 | 5/21/2020 | P | PASS |
Jim Storey
|
|
|
|
BLD-Wall Bracing | 5/19/2020 | 5/20/2020 | 5/20/2020 | A | FAIL |
Jim Storey
|
|
|
shear garage- Tyler *Screened* Phone #: ###-####
|
Fees Due Hold | 5/5/2020 | | 5/11/2020 | | DONE |
|
|
|
|
Telephone call | | | 5/5/2020 | | DONE |
|
|
|
Sent email to contractor that not all plan mod fees were paid.
|
Plan Modification Accepted | | | 5/1/2020 | | DONE |
|
|
|
plan mod - Manual J per Kyle Lepper of LPR Architecture
|
BLD-Wall Bracing | 4/13/2020 | 4/13/2020 | 4/13/2020 | P | PASS |
Jim Storey
|
|
|
Plans are on the south unit in a black tube. Please call after inspection Phone #: ###-#### Inspection requested via web by Tyler Hildebrand
|
BLD-Wall Bracing | 4/7/2020 | 4/7/2020 | 4/7/2020 | P | NR |
Tell Riley
|
|
|
Shear inspection. Call to do a virtual inspection if possible Phone #: ###-#### Inspection requested via web by Tyler Hildebrand//need shear plans//
|
BLD-Footing | 1/27/2020 | 1/28/2020 | 1/28/2020 | P | PASS |
Bob Archibald
|
|
|
stem wall // Scott Phone #: ###-####
|
BLD-Footing | 1/21/2020 | 1/21/2020 | 1/21/2020 | P | PASS |
Jim Storey
|
|
|
SCOTT Phone #: ###-####
|
BLD-Foundation | 1/17/2020 | 1/17/2020 | 1/17/2020 | P | FAIL |
Jim Storey
|
|
|
Scott Phone #: ###-#### ground frozen do not place concrete
|
Routing - PLANNING | 1/13/2020 | | 1/13/2020 | | PASS |
Katelyn Menuge
|
|
|
Plan Mod Pass
|
Issue PAID IN FULL permit | | | 12/23/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 12/23/2019 | | DONE |
|
|
|
|
Telephone call | | | 12/20/2019 | | DONE |
|
|
|
received GC form from Kyle Lepper (kyle@lprarchitecture.com
Let him know we still need 306
|
Telephone call | | | 12/17/2019 | | DONE |
|
|
|
Spoke with a Tyler who wanted to pay fees. informed him we still need the GC to turn in a 302 and 306 form before we can add in the rest of the fees.
|
Meeting | | | 12/6/2019 | | DONE |
|
|
|
sent email to kyle@lprarchitecture.com, tony@tkboise.com and tyler@mbuilt.co informing permit will expire in 19 days and will either need to pay for the permit or submit at a later date (granted 2 extensions)
|
Telephone call | | | 11/19/2019 | | DONE |
|
|
|
left message for kyle and emailed kyle, anthony & tyler informing them this permit will expire 12-25 and has already be granted the two 180 day extensions we allow
|
Extend Review Timeline | | | 6/26/2019 | | DONE |
|
|
|
1st approved 180 day extension per adele. see documents
|
Extend Review Timeline | | | 6/26/2019 | | DONE |
|
|
|
final approved 180 day extension per adele. see documents
|
OVERRIDE | | | 3/25/2019 | | |
|
|
|
|
Plan assigned to (RDP) | 2/20/2019 | 2/20/2019 | 3/25/2019 | | DONE |
Rob Patrick
|
|
|
03/11 sfd L2 Townhouse; 03/05 Failed; Corrections Req'd
|
Routing - PLAN CHECK | 3/25/2019 | | 3/25/2019 | | PASS |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/25/2019 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 3/25/2019 | | DONE |
|
|
|
do not issue without BLD18-02367
need GC form
met
Need RP
|
1st review completed | | | 3/5/2019 | | FAIL |
Rob Patrick
|
|
|
Corrections Req'd
|
Routing - PLAN CHECK | 2/20/2019 | | 3/5/2019 | | FAIL |
Rob Patrick
|
|
|
Corrections Req'd
|
Routing - MECHANICAL | 2/20/2019 | | 2/28/2019 | | PASS |
Troy James
|
|
|
|
Routing - PUBLIC WORKS | 2/20/2019 | | 2/22/2019 | | PASS |
Morgan Webb
|
|
|
|
Route to Impact Fee Review | 2/20/2019 | 2/23/2019 | 2/21/2019 | | PASS |
Shannon Cade
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - PLANNING | 2/20/2019 | | 2/21/2019 | | PASS |
Katelyn Menuge
|
|
|
|
Routing - Addressing | 2/20/2019 | | 2/21/2019 | | PASS |
Doug Chausow
|
|
|
|
Intake Approval | | | 2/20/2019 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 2/20/2019 | | DONE |
|
|
|
|
Intake Approval | | | 2/19/2019 | | |
|
|
|
|
Meeting | | | 2/19/2019 | | |
|
|
|
|
Intake Approval | | | 2/19/2019 | | |
|
|
|
|
Meeting | | | 2/19/2019 | | |
|
|
|
|
Application received | | 2/19/2019 | | | |
|
|
|
|
Application received | | 2/19/2019 | | | |
|
|
|
|
Routing - MECHANICAL | 5/4/2020 | | | | |
|
|
|
|