BLD-Final | 7/18/2019 | 7/18/2019 | 7/18/2019 | A | PASS |
Mike Jordan
|
|
|
home will be opened up, garage door code is 2468. thanks Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
DOC - Permit Finaled | 7/18/2019 | 7/18/2019 | 7/18/2019 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 7/16/2019 | 7/17/2019 | 7/17/2019 | A | NH |
Mike Jordan
|
|
|
garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle. No access.
|
BLD-Energy code compliance | 5/16/2019 | 5/16/2019 | 5/16/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 5/16/2019 | 5/16/2019 | 5/16/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. All issues have been resolved.
|
BLD-Framing/Rough-in | 5/15/2019 | 5/17/2019 | 5/16/2019 | A | CANC |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
|
BLD-Energy code compliance | 5/15/2019 | 5/17/2019 | 5/16/2019 | A | CANC |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
|
BLD-Framing/Rough-in | 5/14/2019 | 5/15/2019 | 5/15/2019 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Install hte missing simpson hold down on iterior shear wall. Repair OSB on interior shear wall at electrical outlets and dryer vents. install missed lateral bracing on A8 and A9 trusses. Strap double top plate break on interior wall at D4G truss interior bearing. Provide gussett type connections for handstack truss above stairway and provide load path. Correction notice posted. Ok to insulate.
|
BLD-Framing/Rough-in | 5/8/2019 | 5/14/2019 | 5/14/2019 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Needs mech ri inspection.
|
BLD-Wall Bracing | 5/6/2019 | 5/6/2019 | 5/6/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Foundation | 4/11/2019 | 4/12/2019 | 4/12/2019 | P | PART |
Mike Jordan
|
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD-Footing | 4/10/2019 | 4/11/2019 | 4/11/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD-Footing | 4/10/2019 | 4/10/2019 | 4/10/2019 | P | NR |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
Issue PAID IN FULL permit | | | 3/21/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 3/21/2019 | | DONE |
|
|
|
|
OVERRIDE | | | 3/6/2019 | | |
|
|
|
|
Plan assigned to (RDP) | 2/20/2019 | 2/20/2019 | 3/6/2019 | | DONE |
Rob Patrick
|
|
|
03/05 sfd L1 ePlan...02/27 Failed
|
Routing - PLAN CHECK | 3/6/2019 | | 3/6/2019 | | PASS |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/6/2019 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 3/6/2019 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 2/20/2019 | | 2/27/2019 | | FAIL |
Rob Patrick
|
|
|
Corrections Req'd
|
1st review completed | | | 2/27/2019 | | FAIL |
Rob Patrick
|
|
|
Corrections Req'd
|
Routing - MECHANICAL | 2/20/2019 | | 2/22/2019 | | PASS |
Troy James
|
|
|
|
Route to Impact Fee Review | 2/20/2019 | 2/23/2019 | 2/21/2019 | | PASS |
Shannon Cade
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - PLANNING | 2/20/2019 | | 2/20/2019 | | PASS |
Sue Cummings
|
|
|
Airport Influence Area "A"
|
Routing - Addressing | 2/20/2019 | | 2/20/2019 | | PASS |
Doug Chausow
|
|
|
Changed Roan Meadows Dr to Roan Meadows Ct
|
Routing - PUBLIC WORKS | 2/20/2019 | | 2/20/2019 | | PASS |
Morgan Webb
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 2/20/2019 | | DONE |
|
|
|
|
Intake Approval | | | 2/20/2019 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 2/20/2019 | | DONE |
|
|
|
|
Application received | | | 2/19/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Feb 19 2019 10:58AM
|