Permit Information
Permit NumberBLD19-00591
StatusFinaled
Name STEED CONSTRUCTION
Site Address 7960 W RIFLEMAN ST Unit: STE 110
Project NameArtisan Pediatric Eyecare
Customer Number 
ePlanReviewYes
Description
(ARTISAN PEDIATRIC EYECARE – TOWN SQUARE STATION BUILDING “B”) Permit for tenant improvements to an existing 6,974 sq. ft. tenant space previously occupied by Toy Town for a new medical office. Work to include: demolition of portions of exterior wall, existing interior non-bearing walls, doors, and plumbing; relocating exterior storefront doors and installing new windows; new interior non-bearing partition walls and doors; new gypsum board and suspended ACT ceilings; new accessible single user restrooms; electrical power and lighting; new mechanical RTU, exhaust fans, mini-split units, and ductwork; new plumbing work; and interior finishes in compliance with 2015 IBC Ch. 8. Special inspections required per the attached Form 310. This building has a fire sprinkler system used for building area increase and for story increase. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **JAR**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  4/3/2020 DONE
1st notice
Print Statement  3/11/2020 DONE
Second Notice 1/9/20201/22/2020 DONE
This permit finaled on the web by Nate Walrath
First Notice 12/5/201912/30/2019 DONE
mailed 1-1-20
BLD-Final11/22/201911/25/201911/25/2019APASS
DetailsMike Jordan
Mike Phone #: ###-####. Ok for perm occ.
Permanent Occupancy  11/25/2019 DONE
BLD-Final8/1/20198/2/20198/2/2019APART
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. Ok for temp occ. ok to see clients. Needs to provide ADA compliant counter at main check in desk.
BLD-Final7/25/20197/26/20197/26/2019PPART
DetailsTell Riley
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman//temp occupancy to move in equipment//no patient exams until final occupancy//
FIRE-Final Inspection7/25/20197/26/20197/26/2019PPASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work complete.

Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman
BLD-Ceiling Grid Inspection6/20/20196/20/20196/20/2019PPASS
DetailsMike Jordan
Early afternoon Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman
BLD-Ceiling Grid Inspection6/19/20196/19/20196/19/2019PFAIL
DetailsMike Jordan
provide means of keeping main and cross runners from spreading.
BLD-Ceiling Grid Inspection6/18/20196/19/20196/19/2019ANR
DetailsMike Jordan
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. Mech inspection above grid has failed.
BLD-Framing/Rough-in4/26/20194/26/20194/26/2019PPASS
DetailsMike Jordan
Jim Phone #: ###-####. Interior steel stud framed walls,hardlids and soffits only.
Permit Ready to Issue  4/9/2019 DONE
ALL MET: kevin.raymes@steedconstruction.com

NEED
GC form and Revised Cert of Value
Issue PAID IN FULL permit  4/9/2019 DONE
Print Occupancy Form  4/9/2019 DONE
Plan assigned to (JAR)3/8/20193/8/20194/8/2019 DONE
DetailsJulie Romig
04/10 - 2nd Rev - 1st Rev Comp - L3 Artisan Pediatric Eyecare
Routing - PLAN CHECK4/4/2019 4/8/2019 PASS
DetailsJulie Romig
PLANS/APPL TAKEN TO FRONT DESK  4/8/2019 DONE
Route to Impact Fee Review4/2/20194/5/20194/2/2019 PASS
DetailsKarina Myles
Review requested for Commercial Permit
Routing - FIRE3/8/20193/8/20194/1/2019 PASS
DetailsMark Scharfen
IFC Review 04.01.2019.pdf uploaded.
1st review completed  4/1/2019 FAIL
DetailsJulie Romig
Routing - PLAN CHECK3/8/2019 4/1/2019 FAIL
DetailsJulie Romig
Routing PW Environmental3/12/2019 3/18/2019 PASS
DetailsRick Christenson
Routing - MECHANICAL3/12/2019 3/12/2019 PASS
DetailsTroy James
Routing PW Solid Waste3/12/2019 3/12/2019 PASS
DetailsEvan Carpenter
Routing - PUBLIC WORKS3/8/2019 3/12/2019 PASS
DetailsAngela Hardy
Routing - MECHANICAL3/8/2019 3/11/2019 FAIL
DetailsTroy James
Emailed correction to Mechanical Engineer and Architect.
Routing - PLUMBING3/8/2019 3/11/2019 PASS
DetailsDaryl Spivey
Increase cold water sizing to 1 1/2 to meet required demand for plumbing fixtures.
Routing - PLANNING3/8/2019 3/11/2019 PASS
DetailsNicolette Womack
Routing - Addressing3/8/2019 3/11/2019 PASS
DetailsDoug Chausow
Routing - Design Review3/8/2019 3/8/2019 PASS
DetailsKatelyn Menuge
CZC19-00045
Intake Approval  3/6/2019 PASS
Intake Approval  2/28/2019 FAIL
DetailsBrian McGowan
Please provide the following information in order to process the Prescreen;
1. Sheet A501 shows an exterior door being added. Provide Planning and Zoning Approval Letters.

Thank you,
Application received  2/26/2019 DONE
Application submitted via PDS Online on Feb 26 2019 3:06PM