Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD19-00740
StatusFinaled
Name MJT CONSTRUCTION INC
Site Address 7100 W STATE ST
Project NameAlbertsons Interior Remodel
Customer Number 
ePlanReviewYes
Description
(ALBERTSONS - NORTHGATE SHOPPING CENTER) Permit for the replacement and installation of new sales area equipment, check stands and relocate floral department. New work to include: non-load bearing partition walls, millwork, (12) checkout stations, (2) slider entry doors, rooftop mechanical system, below slab plumbing work, (2) sinks in deli area, sink in floral area, water heater, floor sinks, cleanouts, below slab electrical work, conduit, wiring, and outlets. This building is fully fire sprinkled and has an approved fire alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Note: Special Inspections Required see form 310. Racking at back of store not approved under this permit separate permit is required. MDH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 9/29/20199/26/2019 DONE
This permit finaled on the web by Michele Rodgers
First Notice8/27/20198/27/20199/19/2019 DONE
DetailsBrandon Shaw
mailed 9-20-19
BLD-Final8/26/20198/27/20198/27/2019PPASS
DetailsBrandon Shaw
Call ahead 15 minutes // TOM Phone #: ###-####
DOC - Permit Finaled8/27/20198/27/20198/27/2019PPASS
DetailsBrandon Shaw
FIRE-Final Inspection8/26/20198/27/20198/27/2019APASS
DetailsJim Page
Previously noted items have been corrected, fire sprinkler ispections are complete, no fire alarm modifications, fire extinguishers are in common areas with current inspection tags. Final life fire safety inspection for area of work complete.

TOM Phone #: ###-####
FIRE-Final Inspection8/6/20198/7/20198/7/2019AFAIL
DetailsJim Page
FIR permits (2 permits for this project) for fire sprinkler work have not been inspected or finaled, life fire safety inspection will not be signed off until fire sprinkler permits are finaled.

Tom Phone #: ###-####
BLD-Ceiling Grid Inspection6/26/20196/27/20196/27/2019APASS
DetailsTony Young
ceiling over beer // Tom Phone #: ###-####
BLD-Other5/9/20195/10/20195/10/2019APART
DetailsTony Young
t bar // Tom Phone #: ###-####,, west cart storage area,, ok after trades
BLD-Footing5/3/20195/6/20195/6/2019APART
DetailsBrandon Shaw
Tom-car stoarge
Pending Special inspection...
BLD-Framing/Rough-in5/2/20195/3/20195/3/2019PPASS
DetailsBrandon Shaw
Tom Phone #: ###-####
BLD-Footing5/2/20195/3/20195/3/2019PCANC
DetailsTony Young
Tom Phone #: ###-#### canel per Tom
BLD-Footing4/22/20194/23/20194/23/2019PPASS
DetailsJim Sly
Tom Phone #: ###-####
Cart storage .....West side.
BLD-Framing/Rough-in4/16/20194/17/20194/17/2019APART
DetailsTony Young
Tom Phone #: ###-####,, immunization room extension ok
BLD-Framing/Rough-in4/15/20194/16/20194/16/2019APART
DetailsTony Young
Austin Phone #: ###-####,, flower cooler area walls ok
BLD-Framing/Rough-in4/12/20194/12/20194/12/2019PNR
DetailsBrandon Shaw
All trades need to aquire permits...
Issue PAID IN FULL permit  4/11/2019 DONE
(F) Reprint permit  4/11/2019 DONE
Inspection Record Card- Bld  4/11/2019 DONE
Routing - PLAN CHECK4/10/2019 4/10/2019 PASS
DetailsMichael Hanson
PLANS/APPL TAKEN TO FRONT DESK  4/10/2019 DONE
DetailsMichael Hanson
Permit Ready to Issue  4/10/2019 DONE
met-Need GC
met-Need Rev Val
Plan assigned to (M_H)3/20/2019 4/10/2019 DONE
DetailsMichael Hanson
1st review completed - 04/02 #518 L2 ePlan
Route to Impact Fee Review4/1/20194/4/20194/2/2019 PASS
DetailsKarina Myles
Review requested for Commercial Permit
Routing - FIRE3/20/20193/20/20194/1/2019 PASS
DetailsMark Scharfen
IFC Review 04.01.2019.pdf uploaded. Passed.
1st review completed  4/1/2019 FAIL
DetailsMichael Hanson
Routing - PLAN CHECK3/20/2019 3/29/2019 FAIL
DetailsMichael Hanson
See changemarks in ePlan for corrections required.
Routing - MECHANICAL3/20/2019 3/26/2019 PASS
DetailsChad Schwendiman
Routing - PLUMBING3/20/2019 3/21/2019 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - PUBLIC WORKS3/20/2019 3/21/2019 PASS
DetailsAngela Hardy
Routing - Addressing3/20/2019 3/21/2019 PASS
DetailsDoug Chausow
Routing - Design Review3/20/2019 3/21/2019 PASS
DetailsKatelyn Menuge
CZC19-00059
Intake Approval  3/20/2019 PASS
DetailsJoe Bruce
Plans approved by Joe Bruce.
Intake Approval  3/14/2019 FAIL
DetailsJoe Bruce
Please provide the following to complete your prescreen:
1) Planning and Zoning letters of approval are required for the additional rooftop mounted air cooled condenser equipment being added for this project. Please contact Katelyn Menuge at ###-#### kmenuge@cityofboise.org - Design Review for more information on the application requirements for this project. The zoning approval certificate will be required prior to intake approval.
2) All drawings are required to be stamped and signed by and Idaho Licensed Engineer. Please provide a stamp/signature/date on the Refrigeration "R" drawings. No stamp was provided on these drawings.
3) Special Inspections are required for the field welding shown on the structural drawings. Please note the special inspections on the plans and have the engineer and owner fill out and sign Form #310 Statement of Special Inspections reflecting the required special inspections for this project. Upload this document into the documents folder.
4) Provide locations of fire extinguishers on the floor plan for both new and existing extinguishers.
5) Provide cut sheets or details on the plans showing accessibility of new check stands.
Application received  3/9/2019 DONE
Application submitted via PDS Online on Mar 9 2019 11:43AM