Permit Information
Permit NumberBLD19-00751
StatusFinaled
Name EKC INC
Site Address 1072 N LIBERTY ST Unit: 300
Project NameSARMC Cons. Gen. Surgery T.I.
Customer Number 
ePlanReviewYes
Description
(SAINT ALPHONSUS CONS. GEN. SURGERY CLINIC – 3RD FLOOR – SUITE #300) **PLAN MOD (10-8-19) - REVISE FLOOR PLAN LAYOUT INCLUDING DOOR SIZE/HARDWARE, FLOOR PLAN LAYOUT, MECHANICAL, PLUMBING, AND ELECTRICAL DESIGN HAS BEEN REVISED ON THE DRAWINGS. The fire sprinkler system is used for high-rise and for occupancy. To remodel 7,962 sq. ft. of the 3rd floor of an existing medical office building. Work to include: interior noncombustible nonbearing walls, suspended acoustical ceiling, gypsum board soffit, toilet room, new doors, counters, cabinets, mechanical, plumbing, and electrical, and new finishes in compliance with Ch. 8 of the 2015 IBC. The work is required to comply with the approved drawings and with all applicable codes and ordinances. Any alterations or modifications to the building’s Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 and NFPA 72 as regulated by the Boise Fire Department. This facility is an outpatient health clinic with procedure rooms. Since there are only (3) three treatment rooms and the patients will not be rendered incapable of self-preservation, this shall be classified as an outpatient clinic, type “B” occupancy. **JHB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 1/4/20202/5/2020 DONE
This permit finaled on the web by Charlene Meadows
Second Notice 12/6/201912/30/2019 DONE
mailed 1-1-20
First Notice 10/26/201911/26/2019 DONE
mailed 12-2-19
BLD-Final10/16/201910/16/201910/16/2019PPASS
DetailsMike Jordan
Inspection requested via web by James Hibbard. Ok for perm occ.
FIRE-Final Inspection10/15/201910/16/201910/16/2019APASS
DetailsTroy Cobbley
Life safety passed. No card on site to sign.

7am
Phone #: ###-#### Inspection requested via web by James Hibbard
FIRE-Alarm Testing10/15/201910/16/201910/16/2019AFAIL
DetailsTroy Cobbley
Fire alarm testing needs to be scheduled with the project related FIR permit. 7am
Phone #: ###-#### Inspection requested via web by James Hibbard
Permanent Occupancy  10/16/2019 DONE
Permit Ready to Issue  10/15/2019 DONE
PLAN MOD
CHANGE STATUS TO (ISS)  10/15/2019 DONE
plan mod fee paid change status to ISS
Plan assigned to (JHB)10/4/201910/4/201910/11/2019 PASS
DetailsJoe Bruce
10/15 (plan mod) St Alphonsus - suite #300
Routing - MECHANICAL10/8/2019 10/11/2019 PASS
DetailsTroy James
Routing - PLAN CHECK10/8/2019 10/10/2019 PASS
DetailsJoe Bruce
Routing - PLUMBING10/8/2019 10/9/2019 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Route to Impact Fee Review10/4/201910/7/201910/7/2019 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
FIRE-Final Inspection10/3/201910/4/201910/4/2019AFAIL
DetailsTroy Cobbley
Need the project related fire alarm and fire sprinkler permits finaled. I noted that doors have been revised but there were no stamped plans showing the changes had been approved on site. The single main exit door has been changed to a double door with door magnets. It appears to need to meet IFC chapter 10 "sensor controled door" which will require a sensor and interconnection with the fire alarm system. Please contact Jim at ###-####
Plan Modification Accepted  10/4/2019 DONE
hardware schedule updated per associated changes
BLD-Ceiling Grid Inspection9/10/20199/10/20199/10/2019APASS
DetailsMike Jordan
Mike can you be here after 10 am to inspect the ceiling grid. Phone #: ###-#### Inspection requested via web by James Hibbard
BLD-Ceiling Grid Inspection9/9/20199/9/20199/9/2019PFAIL
DetailsMike Jordan
James Hibbard is the contact on 3rd floor of the Mulvaney building Phone #: ###-#### Inspection requested via web by James Hibbard. Noted missing clips and wires not tied.
FIRE-Sprinkler Rough-in6/5/20196/5/20196/5/2019PCANC
DetailsTroy Cobbley
Wrong permit called in for the inspection type requested.

Contact Jim Hibbard for any questions Phone #: ###-#### Inspection requested via web by James Hibbard
BLD-Framing/Rough-in6/3/20196/3/20196/3/2019PPASS
DetailsMike Jordan
contact Jim Hibbard for any questions Phone #: ###-#### Inspection requested via web by James Hibbard. Interior steel stud framed walls only ok.
BLD-Framing/Rough-in5/23/20195/28/20195/28/2019ANR
DetailsMike Jordan
Contact Jim Hibbard for any questions Phone #: ###-#### Inspection requested via web by James Hibbard. Needs electrical permit and rough in inspections first.
Issue PAID IN FULL permit  4/30/2019 DONE
Print Occupancy Form  4/30/2019 DONE
Plan assigned to (JHB)3/18/20193/18/20193/28/2019 PASS
DetailsJoe Bruce
03/27 (L2) SARMC Cons. Gen. Surgery ePlan
Routing - FIRE3/18/20193/18/20193/28/2019 PASS
DetailsMark Scharfen
IFC Review 03.28.2019.pdf uploaded.
1st review completed  3/28/2019 DONE
DetailsJoe Bruce
PLANS/APPL TAKEN TO FRONT DESK  3/28/2019 DONE
Permit Ready to Issue  3/28/2019  
MET ERIN@EKCCONSTRUCTION.COM
Need
GC FORM
CERT OF VALUE
Plan Reviewer's activity  3/26/2019 DONE
DetailsJoe Bruce
Spoke with Mark Hirschi and received clarification that this is NOT an ambulatory care facility. The procedure rooms will be used for minor procedures that do not render the patient incapable of self-preservation. **JHB**
Routing - PLAN CHECK3/18/2019 3/26/2019 PASS
DetailsJoe Bruce
Routing PW Environmental3/18/2019 3/25/2019 PASS
DetailsTerry Alber
No Pretreatment issues apparent.
Routing PW Solid Waste3/18/2019 3/21/2019 PASS
DetailsEvan Carpenter
No changes to solid waste.
Routing - MECHANICAL3/18/2019 3/19/2019 PASS
DetailsTroy James
Routing - PLUMBING3/18/2019 3/18/2019 PASS
DetailsDaryl Spivey
per plan and ISPC.
Routing - Addressing3/18/2019 3/18/2019 PASS
DetailsDoug Chausow
Suite 300
Routing - PUBLIC WORKS3/18/2019 3/18/2019 PASS
DetailsAngela Hardy
Intake Approval  3/14/2019 PASS
DetailsJavier Guzman
Application received  3/11/2019 DONE
Application submitted via PDS Online on Mar 11 2019 1:41PM