Permit Information
Permit NumberBLD19-00822
StatusFinaled
Name BAILEY CONSTRUCTION AND CONSULTING
Site Address 7701 W OVERLAND RD
Project NameRegal Boise 4DX
Customer Number 
ePlanReviewYes
Description
(REGAL BOISE) The fire sprinkler system is used for building area increase. **The 1-hour fire barrier that enclosues the exit passageway is required to be maintaned for egress.** Permit is to remodel (1) one theater within an existing 21 theater complex. Work is to include the demolition of the existing theater furniture/equipment, new structural frame for stadium style seating, new seating, new plumbing for sensory seating, new electrical work for seating, new lighting, new sound system, and interior finishes in compliance with Ch. 8 of the 2015 IBC. There shall be no change to the existing egress system. This is a fully sprinklered building, any alterations to the sprinkler system will require a separate fire sprinkler permit and will be required to comply with NFPA #13 as regulated by the Boise City Fire Department. A new certificate of occupancy shall be issued to reflect the reduction in seats from 198 to 165 seats. **JHB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 7/13/20208/10/2020 DONE
mailed 8-14-2020
Third Notice 5/12/20207/8/2020 DONE
mailed 7-9-2020
Second Notice 4/13/20205/7/2020 DONE
mailed 5-8-2020
First Notice 3/16/20204/3/2020 DONE
mailed 4-6-2020
BLD-Final3/5/20203/6/20203/6/2020PPASS
DetailsBrandon Shaw
tyler Phone #: ###-####3
DOC - Permit Finaled3/6/20203/6/20203/6/2020PPASS
DetailsBrandon Shaw
FIRE-Final Inspection3/5/20203/6/20203/6/2020APASS
DetailsTroy Cobbley
Life safety passed. The new projector does pause movie and sound upon fire alarm activation./

Tyler Phone #: ###-####
Permanent Occupancy  3/6/2020 DONE
FIRE-Final Inspection3/3/20203/3/20203/3/2020PCANC
DetailsTroy Cobbley
Need a fire alarm permit for the relocated horn/strobes as discussed prior to a life safety inspection.

Tyler Phone #: ###-####
FIRE-Conference2/28/20202/28/20202/28/2020ADONE
DetailsJim Page
Need to verify coverings around screen, could not verify at time of conference. Sprinkler heads will need to be added if obstructions are installed above screen.
FIRE-Final Inspection2/27/20202/28/20202/28/2020ACANC
DetailsJim Page
Request turned into a conference, this request is cancelled.

tyler Phone #: ###-####
BLD-Framing/Rough-in1/31/20201/31/20202/3/2020PPASS
DetailsDave Hannah
Tyler Phone #: ###-#### lower level and stairs
BLD-Framing/Rough-in1/21/20201/21/20201/22/2020PPART
DetailsDave Hannah
Tyler Phone #: ###-#### upper setting area ok to cover
BLD-Conference1/14/20201/14/20201/17/2020PDONE
DetailsDave Hannah
Tyler Phone #: ###-####
FIRE-Conference11/21/201911/21/201911/21/2019PDONE
DetailsTroy Cobbley
Discussed fire alarm, fire sprinkler and life safety requirements.

Ziggy Phone #: ###-####
Issue PAID IN FULL permit  11/21/2019 DONE
Print Occupancy Form  11/21/2019 DONE
Print Occupancy Form  11/21/2019 DONE
Print Occupancy Form  11/21/2019 DONE
Plan assigned to (JHB)10/1/201910/1/201910/16/2019 PASS
DetailsJoe Bruce
10/21 (plan mod) Regal 4DX Theater, ePlan
Routing - PLAN CHECK10/16/2019 10/16/2019 PASS
DetailsJoe Bruce
Permit Ready to Issue  10/16/2019 DONE
MET
Need GC
Need Rev Val
Routing - PLAN CHECK10/10/2019 10/10/2019 FAIL
DetailsJoe Bruce
Exits must be separated by 1/3 the diagonal distance.
Plan resubmittals requested  10/10/2019 DONE
DetailsJoe Bruce
Plan resubmittals received  10/1/2019 DONE
tenant remodel of auditorium 2 of existing (21) screen cinema. per Lucy Wu
CHANGE STATUS TO (REV)  10/1/2019 DONE
resubmittal
Change Expiration Date Only  9/26/2019 DONE
first permit extension requested granted by Joe Bruce. 180 days
Telephone call  9/23/2019  
Spoke with Lucy to see how she would like to continue with this project. she stated they will send in a request for an extension
Expiration Notice8/14/20199/5/20198/14/2019 DONE
DetailsBrittany Hill
Plan assigned to (JHB)4/25/20194/25/20196/11/2019 PASS
DetailsJoe Bruce
06/10 (2nd Rev) 05/17 (L3) Regal 21, 4DX Theater, eplan
Routing - PLAN CHECK6/3/2019 6/11/2019 PASS
DetailsJoe Bruce
Routing Off Site - STRUCTURAL6/3/2019 6/11/2019 PASS
DetailsJoe Bruce
PLANS/APPL TAKEN TO FRONT DESK  6/11/2019 DONE
Permit Ready to Issue  6/11/2019 DONE
Need GC
need rev cert of val
Plan resubmittals received  6/3/2019 DONE
DetailsJoe Bruce
Route to Impact Fee Review5/17/20195/20/20195/17/2019 PASS
DetailsKarina Myles
Review requested for Commercial Permit
Routing - FIRE4/25/20194/25/20195/17/2019 PASS
DetailsErika Akin
Attached comments to case
1st review completed  5/17/2019 FAIL
DetailsJoe Bruce
Plan resubmittals requested  5/17/2019 DONE
DetailsJoe Bruce
Routing - PLAN CHECK4/25/2019 5/16/2019 FAIL
DetailsJoe Bruce
Routing Off Site - STRUCTURAL4/25/2019 5/7/2019 FAIL
DetailsJoe Bruce
KPFF
Routing - Erosion and Sediment4/25/2019 4/25/2019 PASS
DetailsMichael Zawacki
Void, no ESC required, interior renovation.
Routing - PLUMBING4/25/2019 4/25/2019 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - Addressing4/25/2019 4/25/2019 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS4/25/2019 4/25/2019 PASS
DetailsMorgan Webb
NO NEW PLUMBING
Intake Approval  4/22/2019 PASS
Intake Approval  4/4/2019 FAIL
DetailsJoe Bruce
Additional Items Needed on the checklist:
5) Per checklist: Form #304, Registered Design Professional Form was not submitted. Please provide form #304 into the documents folder with the owners signature and design professional information.
6) Per Checklist: Site Specific Fire Flow at the fire hydrant letter is required from Suez Water. Please email: katie.birkenstein@suez.com for your request to receive the required letter for plan review. Upload this document into the documents folder.
Intake Approval  3/29/2019 FAIL
DetailsJoe Bruce
Please note that you have submitted the wrong application for the scope of this project. This should be submitted as a #520 Major TI and not the #502 New Commercial / Addition Application. Provide the following to complete your prescreen:
1) Complete and fill out checklist #520 Major Tenant Improvement Checklist and upload this document into the "documents" folder. This document must be completely filled out and all drawings/documents provided.
2) The drawing file size cannot exceed 1.0 MB per drawing file. Please reduce the electronic file size of the individual drawings that exceed 1.0 MB and upload.
3) Electrical, Mechanical, and Structural drawings do not have the required space reserved for City approval stamps as specified in the Electronic Plans Submittal Standards. Revise sheets with a blank 4” x 2” (4"x4" on cover) space located 3” off the right sheet edge to allow for the title block. Verify ALL plan sheets have the required space for city approval stamp.
4) The Architect's stamp is missing the a date and signature on all the drawings. Please provide the signature and date per the Idaho State Board rules and regulations.
Application received  3/15/2019 DONE
Application submitted via PDS Online on Mar 15 2019 10:17AM
Third Notice 8/15/2020