Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD19-00968
StatusFinaled
Name XP CONSTRUCTION LLC
Site Address 7911 W USTICK RD
Project NameBuilding B - Shell Improvement
Customer Number 
ePlanReviewYes
Description
(BUILDING B – MAIN FLOOR SHELL IMPROVEMENTS) NO OCCUPANCY ALLOWED UNDER THIS PERMIT. TENANT SHALL APPLY FOR CERTIFICATE OF OCCUPANCY PRIOR TO OCCUPYING THE SPACE. Permit is to create a new exterior storefront door opening. Approval is contingent upon adhering to the approved plans on file, CZC18-00309 and attached engineering. Work to include: removal of select portion of exterior wall, new header and king studs per engineering, new storefront double doors, select new exterior concrete landing and sidewalk and interior finishes in compliance with Ch. 8 of the current IBC. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Telephone call  2/20/2020 DONE
left message and send email to inform that there is fees due on this permit
Telephone call  2/7/2020 DONE
email Troy fees due, unable to leave message box is full
Telephone call  1/3/2020 DONE
Left a message (doesn't state name) to touch bases when fees may be paid
Print Statement  11/27/2019 DONE
maied with second notice
Print Statement  11/14/2019 DONE
Print Statement  7/15/2019 DONE
Second Notice 6/20/20197/10/2019 DONE
mailed 7-11
First Notice5/7/20195/7/20196/10/2019 DONE
DetailsJim Sly
mailed 6-11
BLD-Final5/6/20195/6/20195/7/2019PPASS
DetailsJim Sly
Troy Phone #: ###-####
DOC - Permit Finaled5/7/20195/7/20195/7/2019APASS
DetailsJim Sly
FIRE-Final Inspection5/2/20195/2/20195/2/2019PPASS
DetailsMark Scharfen
Conducted fire life safety on vanilla finish. Passed .
Troy Phone #: ###-####
BLD-Framing/Rough-in4/30/20194/30/20194/30/2019PPASS
DetailsJim Sly
Call for access- Troy Phone #: ###-####
BLD-Framing/Rough-in4/29/20194/29/20194/29/2019PCANC
DetailsJim Sly
Call for access- Troy Phone #: ###-####
Inspection Record Card- Bld  4/17/2019 DONE
Issue PAID IN FULL permit  4/17/2019 DONE
Route to Impact Fee Review4/10/20194/13/20194/11/2019 PASS
DetailsShannon Cade
Review requested for Commercial Permit
Permit Ready to Issue  4/11/2019 DONE
ALL MET-
Need
GC form
Revised Cert of Value
Plan assigned to (JG)4/9/20194/9/20194/10/2019 PASS
DetailsJavier Guzman
04/12 L1 Building Core Door addition ePlan
Routing - Design Review4/9/2019 4/10/2019 PASS
DetailsKatelyn Menuge
Routing - PLAN CHECK4/9/2019 4/10/2019 PASS
DetailsJavier Guzman
1st review completed  4/10/2019 DONE
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  4/10/2019 DONE
Routing - Addressing4/9/2019 4/9/2019 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS4/9/2019 4/9/2019 PASS
DetailsAngela Hardy
Plan Reviewer's activity  4/8/2019 DONE
DetailsBrian McGowan
Spoke with Troy about the interior walls. At some previous time the existing walls shown on the original TI were removed. As per Troy, no walls or cabinetry exist to interfere with the installation of the door.
Intake Approval  4/8/2019 PASS
DetailsJavier Guzman
Intake Approval  4/5/2019 FAIL
DetailsBrian McGowan
4/5/19
1. Please provide a sketch showing the existing walls around the area where the proposed door is to be located. The only Floor Plan I can find on record show a desk and walls that will need to be removed or modified.
Intake Approval  4/2/2019 FAIL
DetailsBrian McGowan
4/2/19

1. Please provide the layout of the existing/current Floor Plan. The only Floor Plan I can find on record show a desk and walls that will need to be removed or modified.
Intake Approval  3/29/2019 FAIL
DetailsBrian McGowan
3/29/19
1. Add the name of the Registered Design Professional in Responsible Charge to form #304.
2. The existing Floor Plan provided does not indicate any future door location. Please provide structural calculations for the proposed opening signed and stamped by an Idaho Licensed Engineer.
3.The existing Floor Plan indicates a desk and walls that will need to be moved or removed for this door to be installed. Provide a Demolition Plan showing any proposed changes and a proposed new Floor Plan for any walls to be installed (a wall detail will need to be included if so).
4. Any modifications to electrical or mechanical must be represented.
Intake Approval  3/28/2019 FAIL
DetailsBrian McGowan
Please provide the following information in order for your Prescreen to be approved;
1. A completed Form #304. (Name of the Design Professional)
2. Planning and Zoning Approval Letter for an exterior modification.
3. Please provide the existing layout of the Floor Plan to show how the proposed door will be incorporated with the current floor plan.
4. Please provide the original plans showing the notation for the future door and existing structure. If not, provide engineering as needed/required. (BLD95-00632 mf#971021)
5. Any modifications to electrical or mechanical must be represented.
Application received  3/26/2019 DONE
Application submitted via PDS Online on Mar 26 2019 9:18PM