Telephone call | | | 2/20/2020 | | DONE |
|
|
|
left message and send email to inform that there is fees due on this permit
|
Telephone call | | | 2/7/2020 | | DONE |
|
|
|
email Troy fees due, unable to leave message box is full
|
Telephone call | | | 1/3/2020 | | DONE |
|
|
|
Left a message (doesn't state name) to touch bases when fees may be paid
|
Print Statement | | | 11/27/2019 | | DONE |
|
|
|
maied with second notice
|
Print Statement | | | 11/14/2019 | | DONE |
|
|
|
|
Print Statement | | | 7/15/2019 | | DONE |
|
|
|
|
Second Notice | | 6/20/2019 | 7/10/2019 | | DONE |
|
|
|
mailed 7-11
|
First Notice | 5/7/2019 | 5/7/2019 | 6/10/2019 | | DONE |
Jim Sly
|
|
|
mailed 6-11
|
BLD-Final | 5/6/2019 | 5/6/2019 | 5/7/2019 | P | PASS |
Jim Sly
|
|
|
Troy Phone #: ###-####
|
DOC - Permit Finaled | 5/7/2019 | 5/7/2019 | 5/7/2019 | A | PASS |
Jim Sly
|
|
|
|
FIRE-Final Inspection | 5/2/2019 | 5/2/2019 | 5/2/2019 | P | PASS |
Mark Scharfen
|
|
|
Conducted fire life safety on vanilla finish. Passed . Troy Phone #: ###-####
|
BLD-Framing/Rough-in | 4/30/2019 | 4/30/2019 | 4/30/2019 | P | PASS |
Jim Sly
|
|
|
Call for access- Troy Phone #: ###-####
|
BLD-Framing/Rough-in | 4/29/2019 | 4/29/2019 | 4/29/2019 | P | CANC |
Jim Sly
|
|
|
Call for access- Troy Phone #: ###-####
|
Inspection Record Card- Bld | | | 4/17/2019 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 4/17/2019 | | DONE |
|
|
|
|
Route to Impact Fee Review | 4/10/2019 | 4/13/2019 | 4/11/2019 | | PASS |
Shannon Cade
|
|
|
Review requested for Commercial Permit
|
Permit Ready to Issue | | | 4/11/2019 | | DONE |
|
|
|
ALL MET-
Need
GC form
Revised Cert of Value
|
Plan assigned to (JG) | 4/9/2019 | 4/9/2019 | 4/10/2019 | | PASS |
Javier Guzman
|
|
|
04/12 L1 Building Core Door addition ePlan
|
Routing - Design Review | 4/9/2019 | | 4/10/2019 | | PASS |
Katelyn Menuge
|
|
|
|
Routing - PLAN CHECK | 4/9/2019 | | 4/10/2019 | | PASS |
Javier Guzman
|
|
|
|
1st review completed | | | 4/10/2019 | | DONE |
Javier Guzman
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/10/2019 | | DONE |
|
|
|
|
Routing - Addressing | 4/9/2019 | | 4/9/2019 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 4/9/2019 | | 4/9/2019 | | PASS |
Angela Hardy
|
|
|
|
Plan Reviewer's activity | | | 4/8/2019 | | DONE |
Brian McGowan
|
|
|
Spoke with Troy about the interior walls. At some previous time the existing walls shown on the original TI were removed. As per Troy, no walls or cabinetry exist to interfere with the installation of the door.
|
Intake Approval | | | 4/8/2019 | | PASS |
Javier Guzman
|
|
|
|
Intake Approval | | | 4/5/2019 | | FAIL |
Brian McGowan
|
|
|
4/5/19
1. Please provide a sketch showing the existing walls around the area where the proposed door is to be located. The only Floor Plan I can find on record show a desk and walls that will need to be removed or modified.
|
Intake Approval | | | 4/2/2019 | | FAIL |
Brian McGowan
|
|
|
4/2/19
1. Please provide the layout of the existing/current Floor Plan. The only Floor Plan I can find on record show a desk and walls that will need to be removed or modified.
|
Intake Approval | | | 3/29/2019 | | FAIL |
Brian McGowan
|
|
|
3/29/19
1. Add the name of the Registered Design Professional in Responsible Charge to form #304.
2. The existing Floor Plan provided does not indicate any future door location. Please provide structural calculations for the proposed opening signed and stamped by an Idaho Licensed Engineer.
3.The existing Floor Plan indicates a desk and walls that will need to be moved or removed for this door to be installed. Provide a Demolition Plan showing any proposed changes and a proposed new Floor Plan for any walls to be installed (a wall detail will need to be included if so).
4. Any modifications to electrical or mechanical must be represented.
|
Intake Approval | | | 3/28/2019 | | FAIL |
Brian McGowan
|
|
|
Please provide the following information in order for your Prescreen to be approved;
1. A completed Form #304. (Name of the Design Professional)
2. Planning and Zoning Approval Letter for an exterior modification.
3. Please provide the existing layout of the Floor Plan to show how the proposed door will be incorporated with the current floor plan.
4. Please provide the original plans showing the notation for the future door and existing structure. If not, provide engineering as needed/required. (BLD95-00632 mf#971021)
5. Any modifications to electrical or mechanical must be represented.
|
Application received | | | 3/26/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Mar 26 2019 9:18PM
|