Permit Information
Permit NumberBLD19-01112
StatusFinaled
Name KC GARDNER RIVERWOODS LC
Site Address 800 W MAIN ST Unit: 1200
Project NameGardner Company - Level 12
Customer Number 
ePlanReviewYes
Description
(GARDNER COMPANY) 8th & Main Building – Suite # 1200. This building is sprinklered to comply as a high-rise building. Permit is to remodel a 4,610 square foot office space on the 11,250 square foot 12th floor (Shell and Core done under BLD12-01991). Work is to include: demolition of existing non-bearing walls/doors, construction of interior non-bearing walls to create; a waiting / reception area, 3 conference rooms, 9 individual offices, an open office area, a file storage area, a copy/work room, and a break room. There will be installation of new lighting, installation of new plumbing, installation of new mechanical, and new interior finishes to comply with Chapter 8 of the 2015 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JHB**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Print Statement  3/11/2020 DONE
Print Statement  1/24/2020 DONE
Second Notice 12/6/201912/30/2019 DONE
mailed 1-1-20
First Notice 10/31/201911/26/2019 DONE
mailed 12-2-19
Permanent Occupancy  10/21/2019 DONE
BLD-Final10/18/201910/18/201910/18/2019PPASS
DetailsJim Storey
Larren Phone #: ###-####
FIRE-Final Inspection10/9/201910/10/201910/10/2019APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work complete, signatures provided for associated trades on project signature card.

Laren Phone #: ###-####
FIRE-Final Inspection10/9/201910/9/201910/9/2019PCANC
DetailsJim Page
Inspection request cancelled per conversation with point of contact due to fire alarm failure, inspection request will be rescheduled to coincide with next fire alarm inspection.

Larrin Phone #: ###-####
BLD-Framing/Rough-in7/3/20197/5/20197/5/2019APASS
DetailsJim Storey
LARREN Phone #: ###-#### ele and plm firestopped at floor ok plm permit and insp can not see .
Issue PAID IN FULL permit  6/3/2019 DONE
Print Occupancy Form  6/3/2019 DONE
Plan assigned to (JHB)4/15/20194/15/20195/28/2019 PASS
DetailsJoe Bruce
05/28 (2nd Rev) 04/26 (L2) Gardner Group TI
Routing - PLAN CHECK5/22/2019 5/28/2019 PASS
DetailsJoe Bruce
PLANS/APPL TAKEN TO FRONT DESK  5/28/2019 DONE
Permit Ready to Issue  5/28/2019 DONE
MET (WALK IN)
NEED
GC FORM
REVISED VALUE
Plan resubmittals received  5/22/2019 DONE
DetailsJoe Bruce
Route to Impact Fee Review4/25/20194/28/20194/26/2019 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - PLAN CHECK4/15/2019 4/25/2019 FAIL
DetailsJoe Bruce
1st review completed  4/25/2019 FAIL
DetailsJoe Bruce
Plan resubmittals requested  4/25/2019 DONE
DetailsJoe Bruce
Routing - MECHANICAL4/15/2019 4/16/2019 PASS
DetailsTroy James
Routing - PLUMBING4/15/2019 4/16/2019 PASS
DetailsDaryl Spivey
Per plan and ISPC.
Routing - Addressing4/15/2019 4/16/2019 PASS
DetailsDoug Chausow
Suite 1200
Routing - PUBLIC WORKS4/15/2019 4/16/2019 PASS
DetailsAngela Hardy
Intake Approval  4/15/2019 PASS
DetailsJoe Bruce
Prescreen approved by CDM.
Application received  4/8/2019 DONE
Application submitted via PDS Online on Apr 8 2019 4:56PM