Permit Information
Permit NumberBLD19-01178
StatusFinaled
Name CONSTRUCTION SERVICES & REPAIRS INC
Site Address 10678 W OVERLAND RD
Project NameFlying Pie Pizzaria
Customer Number 
ePlanReviewYes
Description
(FLYING PIE PIZZARIA – NEAR WEST END OF BUILDING) The fire sprinkler system is used for building area increase and for fire area. To combine two tenant spaces (2,780 square feet and 962 square feet) into a 3,763 square foot tenant space for a new restaurant tenant. Work is to include a commercial kitchen with a pizza oven and a Type II hood, two toilet rooms upgraded to be accessible to the disabled, a below grade exterior grease interceptor, a beer cooler, a walk-in cooler, kitchen equipment, and finishes. Portions of the existing concrete floor slab will be saw cut and removed and trenches dug to allow the installation of below grade sewer pipes. After backfilling the trenches, new concrete infill slabs will be placed. The work is required to comply with the approved drawings, with the structural analysis of the roof including details, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 7/14/20208/11/2020 DONE
mailed 8-14-2020
Third Notice 5/12/20207/9/2020 DONE
mailed 7-9-2020
Second Notice 4/16/20205/7/2020 DONE
mailed 5-8-2020
First Notice 3/30/20204/6/2020 DONE
mailed 4-6-2020
Permanent Occupancy  3/20/2020 DONE
BLD-Final3/19/20203/19/20203/19/2020PPASS
DetailsMike Jordan
wayne Phone #: ###-####. All isuues resolved. Ok for perm occ.
BLD-Final3/19/20203/19/20203/19/2020APART
DetailsMike Jordan
Ok for temp occ. Provide ADA restroom signs and toilet flusher needs to be on turning side.
BLD-Final3/18/20203/19/20203/19/2020ANR
DetailsMike Jordan
Wayne Phone #: ###-####
FIRE-Final Inspection3/18/20203/18/20203/18/2020PPASS
DetailsTroy Cobbley
life safety passed.

Wayne Phone #: ###-####
FIRE-Final Inspection3/12/20203/13/20203/13/2020AFAIL
DetailsTroy Cobbley
Provide all smalll documents, remove dead bolt at Kitchen exit door, remove dead bolt at exit door near Rest Rooms and provide approved single action hardware, provide correct address, post occupant load sign, provide alarm system for the CO if required.

Wayne Phone #: ###-####
FIRE-Final Inspection3/12/20203/12/20203/12/2020PFAIL
DetailsTroy Cobbley
I tried calling contact but they did no pick up. I went to job site and found both the front and rear doors locked. No inspection performed. Will need to be rescheduled.

Call for access- Wayne Phone #: ###-####
BLD-Final3/10/20203/10/20203/10/2020PNR
DetailsMike Jordan
Wayne Phone #: ###-####. Needs life/safety and CDHD.
Print Occupancy Form  3/10/2020 DONE
reprint
BLD-Ceiling Grid Inspection2/7/20202/10/20202/10/2020ANR
DetailsMike Jordan
Wayne- call for access Phone #: ###-####. Received smoke and flame spread values for tiles. Also need documentation on how tiles are to be installed.
BLD-Ceiling Grid Inspection2/3/20202/3/20202/3/2020PNR
DetailsMike Jordan
wayne Phone #: ###-####
BLD-Ceiling Grid Inspection12/30/201912/30/201912/30/2019PNR
DetailsMike Jordan
wayne - call for access Phone #: ###-####. Needs MEP's first.
BLD-Framing/Rough-in10/1/201910/2/201910/2/2019APASS
DetailsMike Jordan
Wayne- please call for access Phone #: ###-####. All issues were resolved.
BLD-Framing/Rough-in9/25/20199/25/20199/25/2019PFAIL
DetailsMike Jordan
Wayne Phone #: ###-####. Interior wood framed walls. Needs to foam seal all penetrations through top plates with red foam. Fire block concelaed space at top of double wall behind point of sales.
BLD-Framing/Rough-in9/19/20199/19/20199/19/2019ANR
DetailsMike Jordan
Needs plumbing r.i. inspection first.
BLD-Framing/Rough-in9/18/20199/19/20199/19/2019ANH
DetailsMike Jordan
wayne Phone #: ###-####. No access.
Meeting  8/15/2019 DONE
change of gc do to retirement, no fee per tisha. see documents.
Rods Home Improvement LLP to Construction Services & Repairs INC
(F) Reprint permit  8/15/2019 DONE
Print Occupancy Form  6/28/2019 DONE
Issue PAID IN FULL permit  6/28/2019 DONE
(F) Reprint permit  6/28/2019 DONE
Routing - FIRE6/18/20196/18/20196/26/2019 PASS
DetailsMark Scharfen
06.26.2019-Completed fire review, uploaded rev_fire 06.26.2019.pdf.
Plan assigned to (CJW)5/22/20196/14/20196/26/2019 PASS
DetailsCarl Westfall
(1st done) 06/07/19 (L-3 - 15 days) (eplan - 28 sheets) Flying Pie Pizzaria (routed to staff)
PLANS/APPL TAKEN TO FRONT DESK  6/26/2019 DONE
Permit Ready to Issue  6/26/2019 DONE
emailed florian@flyingpie.org the fees due-let her know the GC will have to sign permit-attached sign off card in approved docs
met-Need GC
met-Need Rev Val
Routing - PLANNING6/18/2019 6/21/2019 PASS
DetailsLeon Letson
Routing - MECHANICAL6/18/2019 6/19/2019 PASS
DetailsTroy James
Routing - PLAN CHECK6/18/2019 6/19/2019 PASS
DetailsCarl Westfall
2nd IBC plan review approved
Plan resubmittals received  6/18/2019 DONE
Route to Impact Fee Review6/11/20196/14/20196/12/2019 PASS
DetailsShannon Cade
Review requested for Commercial Permit
Routing - FIRE5/22/20195/22/20196/11/2019 FAIL
DetailsMark Scharfen
06.11.2019-Completed fire review. Uploaded rev_fire 06.11.2019.pdf and emailed to architect.
1st review completed  6/11/2019 DONE
Plan resubmittals requested  6/11/2019 DONE
Routing - PLAN CHECK5/22/2019 6/10/2019 FAIL
DetailsCarl Westfall
1st IBC plan review completed
Routing PW Environmental5/23/2019 5/29/2019 PASS
DetailsRick Christenson
Routing - MECHANICAL5/22/2019 5/28/2019 FAIL
DetailsTroy James
See Eplan
Routing - PUBLIC WORKS5/22/2019 5/23/2019 PASS
DetailsMorgan Webb
Routing - PLUMBING5/22/2019 5/22/2019 PASS
DetailsDaryl Spivey
per plan and ISPC.
Routing - PLANNING5/22/2019 5/22/2019 FAIL
DetailsLeon Letson
Additional information required regarding number of new seats and available parking for the project.
Routing - Addressing5/22/2019 5/22/2019 PASS
DetailsDoug Chausow
Intake Approval  5/20/2019 PASS
Intake Approval  4/25/2019 FAIL
DetailsJavier Guzman
Provide and upload the following:
• The form #304 is incomplete, fill out the owner information section
• Seems there are a few scaled measurements of the floor plan A101, detail 3 on plan sheet A401, that are incorrect, revise
• Provide section details of the suspended ceiling
• Per ePlan submittal standards reserve the bottom right corner for City electronic stamps. Leave a blank 4” x 2” space located 3” off the right sheet edge to allow for the title block on all electrical, mechanical and plumbing plan sheets (see https://pds.cityofboise.org/media/464072/pdox86_electronic_standards_full_050718.pdf )
• Provide engineering calculations for the new 784 lbs. RTU and the New 804 lbs. MAU or a stamped letter from engineer stating the existing roof can support the new roof equipment.
Application received  4/12/2019 DONE
Application submitted via PDS Online on Apr 12 2019 7:58AM
Third Notice 8/16/2020