Print Statement | | | 3/2/2020 | | DONE |
|
|
|
|
Print Statement | | | 1/16/2020 | | DONE |
|
|
|
|
Third Notice | | 11/30/2019 | 12/30/2019 | | DONE |
|
|
|
mailed 1-1-20 with first follow up
|
First Follow up | | | 12/30/2019 | | DONE |
|
|
|
|
Third Notice | | 10/30/2019 | 11/25/2019 | | DONE |
|
|
|
mailed 12-2-19
|
Third Notice | | 9/23/2019 | 10/25/2019 | | DONE |
|
|
|
mailed 11-1-19
|
Second Notice | | 8/15/2019 | 9/18/2019 | | DONE |
|
|
|
mailed 9-19-19
|
First Notice | | 8/9/2019 | 8/5/2019 | | DONE |
|
|
|
mailed 8-5-2019
|
Print Occupancy Form | | | 7/30/2019 | | DONE |
|
|
|
|
Permanent Occupancy | | | 7/30/2019 | | DONE |
|
|
|
|
BLD-Final | 7/2/2019 | 7/3/2019 | 7/3/2019 | A | PASS |
Tony Young
|
|
|
kevin Phone #: ###-####,, ok for occupancy now
|
BLD-Final | 6/27/2019 | 6/28/2019 | 6/28/2019 | A | PART |
Tony Young
|
|
|
Kevin Phone #: ###-####,, temp occupancy ok,, needs floor elevations, remove dead bolts
|
FIRE-Final Inspection | 6/27/2019 | 6/28/2019 | 6/28/2019 | A | PASS |
Mark Scharfen
|
|
|
Passed fire life safety.
Kevin Phone #: ###-####
|
BLD-Final | 6/26/2019 | 6/27/2019 | 6/27/2019 | P | NR |
Tony Young
|
|
|
Kevin Phone #: ###-####,, need trades ,, f/l/s
|
BLD-Framing/Rough-in | 6/13/2019 | 6/14/2019 | 6/14/2019 | A | PASS |
Tony Young
|
|
|
kevin Phone #: ###-####
|
Fees Due Hold | 6/11/2019 | | 6/13/2019 | | DONE |
Gemma Flores
|
|
|
|
Permit Ready to Issue | | | 5/31/2019 | | DONE |
|
|
|
MET
Need ACHD (bldg4inspection@gmail.com)
MET
need GC
Need rev cert of val
|
Print Occupancy Form | | | 5/31/2019 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 5/31/2019 | | DONE |
|
|
|
|
Print Occupancy Form | | | 5/31/2019 | | DONE |
|
|
|
|
(F) Reprint permit | | | 5/31/2019 | | DONE |
|
|
|
|
Plan assigned to (M_H) | 5/2/2019 | | 5/30/2019 | | DONE |
Michael Hanson
|
|
|
1st review completed - 05/24 #520 ePlan - Pigment
|
Routing - PLAN CHECK | 5/30/2019 | | 5/30/2019 | | PASS |
Michael Hanson
|
|
|
|
Routing - Design Review | 5/30/2019 | | 5/30/2019 | | PASS |
Josh Wilson
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/30/2019 | | DONE |
Michael Hanson
|
|
|
|
Route to Impact Fee Review | 5/23/2019 | 5/26/2019 | 5/24/2019 | | PASS |
Karina Myles
|
|
|
Review requested for Commercial Permit
|
Routing - FIRE | 5/2/2019 | 5/2/2019 | 5/23/2019 | | PASS |
Mark Scharfen
|
|
|
Completed fire review and uploaded rev_fire 05.23.2019.pdf
|
Routing - PLAN CHECK | 5/2/2019 | | 5/23/2019 | | FAIL |
Michael Hanson
|
|
|
See BLD plan review report in ePlan for corrections required.
|
1st review completed | | | 5/23/2019 | | DONE |
Michael Hanson
|
|
|
|
PRINT Activities | | | 5/15/2019 | | DONE |
|
|
|
|
Routing - PLUMBING | 5/2/2019 | | 5/7/2019 | | PASS |
Dan Ediger
|
|
|
Per notes, plans and ISPC
|
Routing - MECHANICAL | 5/2/2019 | | 5/3/2019 | | PASS |
Chad Schwendiman
|
|
|
|
Routing - Design Review | 5/2/2019 | | 5/2/2019 | | FAIL |
Josh Wilson
|
|
|
Ok to replace roof-top unit per Sheet A2.4... Sheet M-1 shows a new ground level unit... clarify this discrepancy
|
Routing - Addressing | 5/2/2019 | | 5/2/2019 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 5/2/2019 | | 5/2/2019 | | PASS |
Morgan Webb
|
|
|
|
Intake Approval | | | 4/29/2019 | | PASS |
|
|
|
|
Intake Approval | | | 4/22/2019 | | FAIL |
Michael Hanson
|
|
|
Provide information for new rooftop unit (size, operating weight, height, etc...)
Reply back with confirmation to delete current HVAC plan showing new unit on pad with ductwork up the outside of the building.
If the new RTU is larger in size than current it will require design review approval.
If the new RTU is heavier it will require structural analysis letter from structural engineer confirming current structural can support the additional weight.
|
Intake Approval | | | 4/19/2019 | | FAIL |
Michael Hanson
|
|
|
Provide planning and zoning approval letter for exterior mechanical work.
Provide site specific fire flow letter
Provide new structural engineering coversheet as stamp on current document is not legible.
|
Application received | | | 4/17/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Apr 17 2019 2:43AM
|