Print Statement | | | 8/13/2020 | | DONE |
|
|
|
1st past due
|
Print Statement | | | 7/22/2020 | | DONE |
|
|
|
1ST MAILED STATEMENT
|
Third Notice | | 4/8/2020 | 4/9/2020 | | DONE |
|
|
|
This permit finaled on the web by Kenny Elumbaugh
|
Telephone call | | | 4/8/2020 | | DONE |
|
|
|
called and spoke with Christy in accounting. She believes the final values were submitted for the wrong project. I explained to her how to submit final values online and she said she and kenny will get together and do that tomorrow. I gave her my direct phone number to call with questions.
|
Third Notice | | 3/10/2020 | 4/3/2020 | | DONE |
|
|
|
mailed 4-6-2020
|
Telephone call | | | 3/30/2020 | | DONE |
|
|
|
emailed applicant to request clarification on why they included trades final values when none were required. Emailed direction of how to submit for final values online.
|
Second Notice | | 2/17/2020 | 3/5/2020 | | DONE |
|
|
|
mailed 3-6-20
|
First Notice | 1/16/2020 | 1/16/2020 | 2/7/2020 | | DONE |
Brandon Shaw
|
|
|
mailed 2-10-20
|
BLD-Final | 1/15/2020 | 1/16/2020 | 1/16/2020 | P | DONE |
Brandon Shaw
|
|
|
Nate Phone #: ###-####
|
DOC - Permit Finaled | 1/16/2020 | 1/16/2020 | 1/16/2020 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Final | 1/16/2020 | 1/16/2020 | 1/16/2020 | P | PASS |
Jim Storey
|
|
|
|
FIRE-Final Inspection | 1/15/2020 | 1/16/2020 | 1/16/2020 | A | PASS |
Jim Page
|
|
|
No fire sprinklers, no fire alarms, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for scope of work is complete.
Nate Phone #: ###-####
|
Letter of compliance/Occupancy | | | 1/16/2020 | | DONE |
|
|
|
|
Zoning Approval | 1/6/2020 | 1/6/2020 | 1/6/2020 | | PASS |
Katelyn Menuge
|
|
|
|
Print Occupancy Form | | | 12/5/2019 | | DONE |
|
|
|
|
Zoning Approval Temp | 12/4/2019 | 12/4/2019 | 12/4/2019 | | PASS |
Katelyn Menuge
|
|
|
Bonded for Landscape
|
BLD-Footing | 11/4/2019 | 11/5/2019 | 11/5/2019 | P | PASS |
Brandon Shaw
|
|
|
Trash enclosure...
|
BLD-Wall Bracing | 10/1/2019 | 10/2/2019 | 10/2/2019 | P | PASS |
Brandon Shaw
|
|
|
Exterior sheeting and re-enforcing for signage and parapets...
|
BLD-Framing/Rough-in | 9/9/2019 | 9/10/2019 | 9/10/2019 | A | PASS |
Brandon Shaw
|
|
|
North and East walls, shear... OK to cover, interior and exteior...
|
BLD-Foundation | 7/9/2019 | 7/10/2019 | 7/10/2019 | P | PASS |
Brandon Shaw
|
|
|
Work in progress... North side entryway, and one of two colunm pads, East side enrty...
|
BLD-Footing | 7/9/2019 | 7/10/2019 | 7/10/2019 | P | PASS |
Brandon Shaw
|
|
|
Work in progress...
|
Issue PAID IN FULL permit | | | 6/18/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 6/18/2019 | | |
|
|
|
|
Permit Ready to Issue | | | 5/31/2019 | | DONE |
|
|
|
NEED
GC FORM
REVISED VALUE
|
Routing Off Site - STRUCTURAL | 5/21/2019 | | 5/30/2019 | | PASS |
Michael Hanson
|
|
|
Passed per ePlan review by D. Haugland @ AHJ.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/30/2019 | | DONE |
Michael Hanson
|
|
|
|
Plan assigned to (M_H) | 4/27/2019 | | 5/30/2019 | | DONE |
Michael Hanson
|
|
|
1st review completed - 05/08 #518 L2 ePlan - Jacksons #173
|
Route to Impact Fee Review | 5/21/2019 | 5/24/2019 | 5/22/2019 | | PASS |
Karina Myles
|
|
|
Review requested for Commercial Permit
|
Routing Off Site - STRUCTURAL | 4/27/2019 | | 5/13/2019 | | FAIL |
Michael Hanson
|
|
|
See corrections required by D. Haugland AHJ engineering.
|
1st review completed | | | 5/9/2019 | | FAIL |
Michael Hanson
|
|
|
|
Routing - PLAN CHECK | 4/27/2019 | | 5/6/2019 | | PASS |
Michael Hanson
|
|
|
|
Routing - Design Review | 4/27/2019 | | 4/30/2019 | | PASS |
Katelyn Menuge
|
|
|
Comply with DR approval DRH19-00113.
|
Intake Approval | | | 4/25/2019 | | FAIL |
Michael Hanson
|
|
|
This permit has failed prescreen due to the following:
1. Missing completed and signed #518 checklist
2. Missing information on #310 form page 1. All fields must be filled out.
|
Intake Approval | | | 4/25/2019 | | |
Javier Guzman
|
|
|
|
Application received | | | 4/23/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Apr 23 2019 11:05AM
|