BLD-Blower Door Test Results | 10/16/2019 | 10/16/2019 | 10/16/2019 | P | DONE |
Tell Riley
|
|
|
4.34 ACH 50 1712 cfm @ 50 pa
|
BLD-Final | 10/16/2019 | 10/16/2019 | 10/16/2019 | P | PASS |
Tell Riley
|
|
|
Vinny Phone #: ###-####//corrections made//
|
DOC - Permit Finaled | 10/16/2019 | 10/16/2019 | 10/16/2019 | P | PASS |
Tell Riley
|
|
|
|
BLD-Final | 9/27/2019 | 10/1/2019 | 10/1/2019 | A | FAIL |
Tell Riley
|
|
|
Vinny Phone #: ###-####//need to seal penetrations at garage house separation wall//add insulation to crawl access door//no attic access 2nd level//add light in closet under stairs//
|
BLD-Energy code compliance | 7/24/2019 | 7/25/2019 | 7/25/2019 | A | PASS |
Tell Riley
|
|
|
Vinny Phone #: ###-####
|
BLD-Energy code compliance | 7/22/2019 | 7/23/2019 | 7/23/2019 | A | CANC |
Tell Riley
|
|
|
Vini Phone #: ###-####
|
BLD-Framing/Rough-in | 7/22/2019 | 7/23/2019 | 7/23/2019 | A | PASS |
Tell Riley
|
|
|
Vini Phone #: ###-####//ok to insulate only//add hanger at girder for beam//add fireblocking at stairway//will check at energy//
|
BLD-Framing/Rough-in | 7/17/2019 | 7/18/2019 | 7/18/2019 | A | NR |
Tell Riley
|
|
|
Vinnie Phone #: ###-####//need plumbing rough in passed///
|
BLD-Energy code compliance | 7/17/2019 | 7/18/2019 | 7/18/2019 | A | CANC |
Tell Riley
|
|
|
Vinnie Phone #: ###-####
|
BLD-Wall Bracing | 7/1/2019 | 7/2/2019 | 7/2/2019 | A | PASS |
Tell Riley
|
|
|
Vinnie Phone #: ###-####//corrections made//
|
BLD-Wall Bracing | 6/25/2019 | 6/27/2019 | 6/27/2019 | P | PART |
Tell Riley
|
|
|
Kerry Phone #: ###-####//add blocking on second story..finish nailing second story//fasten OSB to sill plate all the way around the first floor//
|
BLD-Foundation | 5/23/2019 | 5/24/2019 | 5/24/2019 | P | PASS |
Jim Sly
|
|
|
Dane Phone #: ###-####
|
BLD-Foundation | 5/22/2019 | 5/23/2019 | 5/23/2019 | P | PASS |
Jim Sly
|
|
|
Dane Phone #: ###-####
|
BLD-Foundation | 5/20/2019 | 5/21/2019 | 5/22/2019 | P | NR |
Jim Sly
|
|
|
Dane Phone #: ###-####
|
BLD-Footing | 5/15/2019 | 5/16/2019 | 5/16/2019 | A | PASS |
Jim Sly
|
|
|
Dane Phone #: ###-####
|
BLD-Footing | 5/14/2019 | 5/15/2019 | 5/15/2019 | P | PASS |
Brandon Shaw
|
|
|
Work in progres...
|
OVERRIDE | | | 5/14/2019 | | |
|
|
|
|
Plan assigned to (RDP) | 5/3/2019 | 5/3/2019 | 5/14/2019 | | DONE |
Rob Patrick
|
|
|
05/09 #402 L1 ePlan - SFD...05/08 Failed
|
Routing - PLAN CHECK | 5/14/2019 | | 5/14/2019 | | PASS |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/14/2019 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 5/14/2019 | | DONE |
|
|
|
met
|
Issue PAID IN FULL permit | | | 5/14/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 5/14/2019 | | DONE |
|
|
|
|
1st review completed | | | 5/8/2019 | | FAIL |
Rob Patrick
|
|
|
Corrections Req'd
|
Routing - PLAN CHECK | 4/26/2019 | | 5/8/2019 | | FAIL |
Rob Patrick
|
|
|
Corrections Req'd
|
Routing - PLANNING | 4/26/2019 | | 5/8/2019 | | PASS |
Brent Moore
|
|
|
|
Plan assigned to (M_H) | 4/26/2019 | | 5/3/2019 | | DEFR |
Michael Hanson
|
|
|
05/09 #402 L1 ePlan - SFD
|
Route to Impact Fee Review | 4/26/2019 | 4/29/2019 | 4/29/2019 | | PASS |
Karina Myles
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - MECHANICAL | 4/26/2019 | | 4/29/2019 | | PASS |
Troy James
|
|
|
|
Routing - Addressing | 4/26/2019 | | 4/26/2019 | | PASS |
Doug Chausow
|
|
|
|
Routing - PUBLIC WORKS | 4/26/2019 | | 4/26/2019 | | PASS |
Angela Hardy
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 4/26/2019 | | DONE |
|
|
|
|
Intake Approval | | | 4/26/2019 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 4/26/2019 | | DONE |
|
|
|
|
Application received | | | 4/25/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Apr 25 2019 9:48PM
|