Permit Information
Permit NumberBLD19-01478
StatusUnder Review
Name OKLAND CONSTRUCTION CO INC
Site Address 749 E PARK BLVD
Project NamePark Place - Parking Garage
Customer NumberBLD19-01479
ePlanReviewYes
Description
(2 PERMITS IN EPLAN UNDER BLD19-01478) (PARK PLACE - PARKING GARAGE) (PROJECT MANAGEMENT - ANGIE BROSIOUS) (DRH19-00093) (CFH19-00029) (PARK PLACE APARTMENTS – PARKING GARAGE – NEW BUILDING) (DRH19-00093) (CFH19-00029) (8-12-20 FORMERLY, AN IMAGINARY PROPERTY LINE WAS CONSIDERED BETWEEN THE GARAGE BUILDING AND THE APARTMENT BUILDING. THE BEARING WALLS OF THE APARTMENT BUILDING NEXT TO THE IMAGINARY PROPERTY LINE WERE REQUIRED TO BE CONSTRUCTED OF FIRE-RETARDANT-TREATED WOOD AND TO HAVE A 2-HR FIRE-RESISTANCE-RATING WITH FIRE EXPOSURE FROM EACH SIDE. THE APARTMENT WALLS NEXT TO THE IMAGINARY PROPERTY LINE WERE NOT CONSTRUCTED THAT WAY. THIS PLAN MODIFICATION TO CHANGE THE MASONRY WALLS BETWEEN THE GARAGE AND THE APARTMENT BUILDING TO A 3-HR FIRE-RESISTANCE-RATED FIRE WALL. ACCORDING TO THE PROJECT STRUCTURAL ENGINEER, THE POST-TENSIONED CONCRETE SLABS THAT WILL SUPPORT THE 3-HR FIRE WALLS HAVE A 3-HR FIRE-RESISTANCE-RATING. THE FIRE WALL IS REQUIRED TO EXTEND AT LEAST 30 INCHES ABOVE THE HIGHEST PARKING GARAGE FLOOR WITH THE WALL OF THE APARTMENT BUILDING RATED FOR AT LEAST 1-HR FROM BOTH SIDES ABOVE THAT AS AN INTERIOR BEARING WALL EXPOSED TO THE WEATHER. ALL DOORS IN THE FIRE WALL, INCLUDING THE ROLL-DOWN FIRE DOORS ON THE 1ST STORY, WILL HAVE A 3-HR FIRE-PROTECTION-RATING. TO FIRE BLOCK THE COMBUSTIBLE WALL LOCATED NEXT TO THE FIRE WALL AT THE FLOOR LEVELS AND AT A MAXIMUM OF 8 FEET ON CENTER EACH WAY. THE IMAGINARY PROPERTY LINE IS NO LONGER CONSIDERED AND THE COMBUSTIBLE WALL LOCATED NEXT TO THE MASONRY FIRE WALL IS NOW CONSIDERED TO BE AN INTERIOR WALL HAVING A FIRE-RESISTANCE-RATING OF 1-HR. THE FIRE WALL IS CONSIDERED TO BE THE MEMBRANE ON ONE SIDE WITH 5/8” TYPE “X” GYPSUM BOARD BEING THE MEMBRANE ON THE OTHER SIDE.) The fire sprinkler system is used for fire area and for fire flow and is required to comply with NFPA 13 as a dry system. To construct a 6 level enclosed parking garage having a total floor area of about 135,680 square feet (about 25,338 square feet for each of the lower 5 levels and about 8,990 square feet for the 6th level). The apartment building constructed under permit BLD19-01479 will entirely surround this parking garage building. The parking garage will have a total of 356 parking spaces. At least 8 of those 356 parking spaces are required to be accessible to the disabled (at least 2 of those 8 are required to be van accessible to the disabled). All floor drains in the covered portion of the garage will drain through a sand and oil interceptor. Work is to include concrete footings, concrete foundations, concrete slabs on grade, 2-hr post tensioned concrete floors, 3-hr concrete columns, 3-hr concrete shear and bearing walls, 2-hr fire walls to entirely surround the parking garage building and to completely separate it from the apartment building, 90 minute side-hinged swinging fire doors and 90 minute vehicle roll down fire doors in the 2-hr fire wall, two 2-hr stairway enclosures with steel and concrete stairways and steel guards, two 2-hr elevator shafts with elevators and vestibules, two 2-hr trash chutes with 1-hr vestibules and 2-hr trash rooms at the bottom, bike storage rooms, maintenance storage rooms, two 2-hr mechanical shafts with exhaust fans, and concrete and steel guards. The tallest elevator is required to comply as an accessible means of egress for the disabled having standby power. Special Inspection is required for soils, concrete (including post tensioning), and masonry. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Routing - PLAN CHECK8/13/2020 8/13/2020 PASS
DetailsCarl Westfall
Routing - PLAN CHECK8/11/2020 8/12/2020 PASS
DetailsCarl Westfall
Plan intake review approved
Plan Modification Accepted  8/11/2020 DONE
3HR firewall and openings at parking garage. Fireblocking at corridior wall to ratain 1HR fire resistance rating
BLD-Foundation6/22/20206/24/20206/25/2020PPEND
DetailsDave Hannah
Area D foundation. MTI is schedule for a Thursday am pour. Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Concrete5/5/20205/5/20205/6/2020PPART
DetailsBrandon Shaw
LEVEL 6 SUSPENDED SLAB POUR - POUR AREA A. EAST SHEAR WALL @ LEVEL 5.
Pend Special inspection...
BLD-Concrete4/24/20204/24/20204/28/2020PPEND
DetailsDave Hannah
10 columns @ level 5 area A (south west corner of level 5) Phone #: ###-#### Inspection requested via web by Garrett Camp ok after spec inspection sign offs
BLD-Concrete4/27/20204/27/20204/28/2020PPEND
DetailsDave Hannah
SUSPENDED SLAB POUR - LEVEL 5 POUR AREA C; SHEAR WALL @ SOUTH SIDE OF LEVEL 5. POURING TOMORROW MORNING. Phone #: ###-#### Inspection requested via web by Garrett Camp ok after spec inspection sign offs
BLD-Concrete4/17/20204/20/20204/21/2020PPART
DetailsDave Hannah
PT deck level 5 pour 2. MTI is scheduled. 4 am Tuesday pour. Phone #: ###-#### Inspection requested via web by Jim Williams work i progress
BLD-Concrete4/17/20204/20/20204/21/2020APART
DetailsDave Hannah
Shear wall west elevation level 5-6 Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Concrete4/13/20204/13/20204/14/2020PPASS
DetailsDave Hannah
LEVEL 5 - POUR AREA A - PT DECK. COLUMNS @ EAST SIDE LEVEL 4-5 AND LEVEL 4 - NORTH SHEAR WALL. Phone #: ###-#### Inspection requested via web by Garrett Camp
BLD-Conference3/26/20203/27/20203/31/2020PPART
DetailsDave Hannah
south shear wall and 10 columns pour B. MTI has been scheduled. Concrete scheduled for 10 am Monday Inspection requested via web by Jim Williams
BLD-Concrete3/23/20203/24/20203/25/2020PPEND
DetailsDave Hannah
West shear wall reinforcement, 10 columns. suspended slab level 4 pour B. MTI is scheduled 4 am 3/25 concrete. Phone #: ###-#### Inspection requested via web by Jim Williams ok after spec inspection sign offs
BLD-Concrete3/19/20203/19/20203/19/2020PPEND
DetailsDave Hannah
Columns and shear wall Phone #: ###-#### Inspection requested via web by Jim Williams ok after spec inspection sign offs
BLD-Concrete3/9/20203/10/20203/11/2020ACANC
DetailsDave Hannah
LEVEL 3 - SOUTH SHEAR WALL; 10 COLUMNS LEVEL 3 POUR B AREA. Phone #: ###-#### Inspection requested via web by Garrett Camp
BLD-Concrete3/11/20203/11/20203/11/2020PPEND
DetailsDave Hannah
SUSPENDED SLAB LEVEL 3 - AREA C Phone #: ###-#### Inspection requested via web by Garrett Camp ok after spec inspection sign offs
BLD-Concrete3/2/20203/3/20203/9/2020PPASS
DetailsDave Hannah
LEVEL 3 - SUSPENDED SLAB - POUR B Phone #: ###-#### Inspection requested via web by Garrett Camp
BLD-Concrete3/2/20203/2/20203/2/2020PCANC
DetailsDave Hannah
COLUMNS @ LEVEL 3 AREA A - FIRST POUR Phone #: ###-#### Inspection requested via web by Garrett Camp ok after spec inpection sign off
BLD-Concrete2/27/20202/27/20202/28/2020APEND
DetailsDave Hannah
north shear wall, 2 columns at ramp Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Concrete2/19/20202/25/20202/25/2020APEND
DetailsDave Hannah
PT slab Pour 1 level 3 Phone #: ###-#### Inspection requested via web by Jim Williams ok after spec inspection sign off
BLD-Concrete2/19/20202/20/20202/25/2020PPEND
DetailsDave Hannah
Columns and shear wall parking garage east Phone #: ###-#### Inspection requested via web by Jim Williams ok after spec inspection sign off
BLD-Concrete2/12/20202/13/20202/19/2020APART
DetailsDave Hannah
10 columns and west concrete shear wall level 2-3 Phone #: ###-#### Inspection requested via web by Jim Williams
Print Occupancy Form  11/5/2019 DONE
Issue PAID IN FULL permit  11/5/2019 DONE
Telephone call  11/4/2019 DONE
sent an email to kim informing this permit is expired and that she may send in a request for an extension
OVERRIDE  10/31/2019  
Plan assigned to (CJW)6/3/20197/12/201910/31/2019 PASS
DetailsCarl Westfall
(1st done) 07/05/19 (New Building - 25 days) (eplan - 330 sheets) Park Place Garage Building (issue after footing permit)
Plan Reviewer's activity  10/31/2019 PASS
This permit was held up until after the footing and foundation permit was approved (BLD19-03918).
PLANS/APPL TAKEN TO FRONT DESK  10/31/2019 DONE
Permit Ready to Issue  10/31/2019 DONE
MET WESTON@GARDNERCOMPANY.NET
**DO NOT ISSUE WITHOUT BLD19-01479**

NEED
RP
MET
GC Form
ACHD
Revised Value
Routing - PLANNING10/11/2019 10/15/2019 PASS
DetailsDavid Moser
Routing PW Street Lights10/11/2019 10/14/2019 PASS
DetailsTom Marshall
Routing - PLAN CHECK10/11/2019 10/14/2019 PASS
DetailsCarl Westfall
Plan resubmittals received  10/11/2019 DONE
Plan resubmittals requested  10/8/2019 DONE
Routing - FIRE9/24/20199/24/201910/7/2019 PASS
DetailsErika Akin
Attached comments to case
Routing Off Site - STRUCTURAL9/24/2019 10/4/2019 PASS
DetailsCarl Westfall
Jared Bauder (Jacobs - CH2MHill)
Routing - PLAN CHECK9/19/2019 10/2/2019 PASS
DetailsCarl Westfall
Pending Structural
Routing - Design Review9/24/2019 10/2/2019 PASS
DetailsJosh Wilson
Routing - PLUMBING9/24/2019 9/30/2019 PASS
DetailsDan Ediger
Per plans and ISPC. See Redlines
Routing - MECHANICAL9/24/2019 9/26/2019 PASS
DetailsTroy James
Routing PW Street Lights9/24/2019 9/25/2019 FAIL
DetailsTom Marshall
Routing - PLANNING9/24/2019 9/24/2019 FAIL
DetailsDavid Moser
need to provide access agreement with Parks for connection to greenbelt and Public Works approved Site Restoration Plan
Routing - PLAN CHECK9/19/2019 9/24/2019 FAIL
DetailsCarl Westfall
Delay in routing do to improperly uploaded drawings
Plan resubmittals received  9/19/2019 DONE
Routing - FIRE8/17/20198/17/20199/10/2019 FAIL
DetailsErika Akin
Attrached comments to case and emailed architect
Plan resubmittals requested  9/10/2019 DONE
Routing Off Site - STRUCTURAL8/17/2019 9/5/2019 FAIL
DetailsCarl Westfall
Jared Bauder (Jacobs - CH2MHill)
Plan Reviewer's activity  9/4/2019 DONE
Emailed the Structural Engineer Consultant asking about the status of the 2nd review. Also talked to Fire.
Routing - Design Review8/17/2019 8/23/2019 FAIL
DetailsJosh Wilson
DR Modification not yet approved (DRH19-00362)
Routing - Addressing8/17/2019 8/21/2019 PASS
DetailsDoug Chausow
Routing PW Drainage8/17/2019 8/21/2019 PASS
DetailsBrian Murphy
Routing PW Street Lights8/20/2019 8/20/2019 FAIL
DetailsTom Marshall
Need a street light plan.
Routing - PLUMBING8/17/2019 8/20/2019 FAIL
DetailsDan Ediger
Complete corrections acording to the ChangeMark
Routing - PLANNING8/17/2019 8/20/2019 FAIL
DetailsDavid Moser
Need access agreement with Parks and Rec and need Site Restoration Plan approved by Public Works and Parks & Rec
Routing - MECHANICAL8/17/2019 8/19/2019 PASS
DetailsTroy James
Routing - PLAN CHECK8/14/2019 8/17/2019 FAIL
DetailsCarl Westfall
Plan resubmittals received  8/14/2019 DONE
Route to Impact Fee Review7/27/20197/30/20197/30/2019 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE6/3/20196/3/20197/11/2019 FAIL
DetailsErika Akin
Attached comments to case and emailed architect
Routing - PLAN CHECK6/3/2019 7/11/2019 FAIL
DetailsCarl Westfall
Park Place Apartments - Garage
1st review completed  7/11/2019 DONE
Plan resubmittals requested  7/11/2019 DONE
Routing Off Site - STRUCTURAL6/3/2019 6/14/2019 FAIL
DetailsCarl Westfall
Jared Bauder (Jacobs - CH2MHill)
Routing PW Drainage6/4/2019 6/11/2019 FAIL
DetailsBrian Murphy
CAN BE PASSED BUT NEED TO PASS GRADING PLAN FIRST
Routing PW Flood Plain6/4/2019 6/10/2019 PASS
DetailsJason C. Taylor
Project is outside Special Flood Hazard Area, no floodplain review required. If you have any questions, please call Jason Taylor at ###-####.
Routing - MECHANICAL6/3/2019 6/6/2019 FAIL
DetailsTroy James
See eplan
Routing - PLUMBING6/3/2019 6/5/2019 FAIL
DetailsDan Ediger
Sizing per ISPC
Routing - PLANNING6/3/2019 6/5/2019 FAIL
DetailsDavid Moser
need to provide access agreement with Parks for connection to greenbelt and Public Works approved Site Restoration Plan
Routing - Addressing6/3/2019 6/5/2019 FAIL
DetailsDoug Chausow
Provide separate floor plans for floors 4 and 5 (currently combined onto one sheet) with unit numbers.
Routing PW Street Lights6/4/2019 6/5/2019 FAIL
DetailsTom Marshall
Routing - Erosion and Sediment6/3/2019 6/5/2019 PASS
DetailsMichael Zawacki
Please refer to ESC19-00542 issued with grading permit as main site permit.
Routing PW Solid Waste6/4/2019 6/5/2019 PASS
DetailsPeter J. McCullough
SW containers to be moved by building staff to designated location
Routing PW Sewer Design6/4/2019 6/4/2019 PASS
DetailsDeAnn Brown
Routing - PUBLIC WORKS6/3/2019 6/4/2019 PASS
DetailsAngela Hardy
Intake Approval  6/3/2019 PASS
DetailsCarl Westfall
Prescreen approved/fees paid 6-3-19
Routing - Design Review6/3/2019 6/3/2019 FAIL
DetailsJosh Wilson
See changemarks on multiple sheets. Elevations do not match those approved with DRH19-00093. Submit a Design Review modification.
Plan Reviewer's activity  5/31/2019 PASS
Plan intake review approved
Intake Approval  5/14/2019 FAIL
(5-14-19) Refer to the circled items in the plan intake checklist. Resolve each item as directed. CJW
Intake Approval  5/6/2019 FAIL
M and P sheets not oriented properly. They were deleted. Completely filled out plan intake checklist 502 required.
Application received  4/30/2019 DONE
Application submitted via PDS Online on Apr 30 2019 4:24PM
Plan assigned to (CJW)8/11/20208/11/2020   
DetailsCarl Westfall
plan mod - Park place apartments (routed to staff)