Routing - MECHANICAL | 2/18/2020 | | 2/18/2020 | | PASS |
Troy James
|
|
|
Resubmitted manual j report
|
BLD-Final | 1/14/2020 | 1/15/2020 | 1/15/2020 | P | PASS |
Tell Riley
|
|
|
Phone #: ###-#### Inspection requested via web by James Jackson//corrections made//final complete//
|
DOC - Permit Finaled | 1/15/2020 | 1/15/2020 | 1/15/2020 | P | PASS |
Tell Riley
|
|
|
|
BLD-Final | 1/13/2020 | 1/14/2020 | 1/14/2020 | A | FAIL |
Tell Riley
|
|
|
Phone #: ###-#### Inspection requested via web by James Jackson//CN posted on electrical panel--need bollard for mechanical protection-need to seal gyp board behind furnace//
|
BLD-Blower Door Test Results | 1/14/2020 | 1/14/2020 | 1/14/2020 | A | DONE |
Tell Riley
|
|
|
5.0 ACH 50
|
BLD-Energy code compliance | 10/15/2019 | 10/16/2019 | 10/16/2019 | A | PASS |
Tell Riley
|
|
|
Phone #: ###-#### Inspection requested via web by James Jackson
|
BLD-Framing/Rough-in | 10/14/2019 | 10/15/2019 | 10/15/2019 | A | PASS |
Tell Riley
|
|
|
Phone #: ###-#### Inspection requested via web by James Jackson//corrections made//
|
BLD-Framing/Rough-in | 10/11/2019 | 10/14/2019 | 10/14/2019 | A | PART |
Tell Riley
|
|
|
Phone #: ###-#### Inspection requested via web by James Jackson//need truss plans and fire blocking at concealed space//ok to insulate only//
|
Routing - MECHANICAL | 10/9/2019 | | 10/9/2019 | | PASS |
Chad Schwendiman
|
|
|
Revised manual J
|
Meeting | | | 10/9/2019 | | DONE |
|
|
|
Plan mod cancelled per Chad S., minor change only.
|
Plan Modification Accepted | | | 10/8/2019 | | DONE |
|
|
|
per James Jackson of Harding Homes - start plan mod - Manual J workflow
|
BLD-Wall Bracing | 9/20/2019 | 9/23/2019 | 9/23/2019 | A | PART |
Tell Riley
|
|
|
Phone #: ###-#### Inspection requested via web by James Jackson//ok to wrap exterior//check blocking and portal frame straps at framing//will need to add holddown at front door where STHD14 is in wrong location//
|
BLD-Footing | 8/13/2019 | 8/13/2019 | 8/13/2019 | P | PASS |
Tell Riley
|
|
|
Gilbert Phone #: ###-####//setbacks ok per plans//
|
Issue PAID IN FULL permit | | | 8/1/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/1/2019 | | DONE |
|
|
|
|
OVERRIDE | | | 7/29/2019 | | |
|
|
|
|
Plan assigned to (J_N) | 6/27/2019 | 6/27/2019 | 7/29/2019 | | DONE |
Jenny Nelson
|
|
|
07/10 sfd L1 ePlan.3rd review, failed planning again. 2nd reveiw, wall bracing still inadequate. 1st complete 7/8, inadequate wall bracing
|
Routing - PLANNING | 7/29/2019 | | 7/29/2019 | | PASS |
Ethan Mansfield
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/29/2019 | | DONE |
Jenny Nelson
|
|
|
|
Permit Ready to Issue | | | 7/29/2019 | | DONE |
|
|
|
|
Routing - PLANNING | 7/25/2019 | | 7/26/2019 | | FAIL |
Ethan Mansfield
|
|
|
All structures must be located outside of 20 feet from the front property line per notes 7 and 10 of Eronel Sub Plat.
|
Routing - PLAN CHECK | 7/25/2019 | | 7/25/2019 | | PASS |
Jenny Nelson
|
|
|
|
Routing - PLANNING | 7/22/2019 | | 7/22/2019 | | FAIL |
Ethan Mansfield
|
|
|
All structures must be build outside the two stacked 10' easements (20' total) from front property line. There is a 10' ACHD storm drain easement and a 10' public utilities easement that are stacked for a total of 20' from the front property line.
|
Routing - PLAN CHECK | 7/22/2019 | | 7/22/2019 | | FAIL |
Jenny Nelson
|
|
|
|
1st review completed | | | 7/8/2019 | | DONE |
Jenny Nelson
|
|
|
|
Routing - PLAN CHECK | 6/27/2019 | | 7/8/2019 | | FAIL |
Jenny Nelson
|
|
|
inadequate wall bracing
|
Routing - MECHANICAL | 7/2/2019 | | 7/2/2019 | | PASS |
Chad Schwendiman
|
|
|
|
Route to Impact Fee Review | 6/27/2019 | 6/30/2019 | 6/28/2019 | | PASS |
Eric Bilimoria
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - MECHANICAL | 6/27/2019 | | 6/28/2019 | | FAIL |
Chad Schwendiman
|
|
|
The R value of the ceilings doesn't match the submitted plans
|
Routing - PLANNING | 6/27/2019 | | 6/28/2019 | | FAIL |
Ethan Mansfield
|
|
|
There are 2 10' stacked easements along the front property line (See Plat notes 7 and 10). Please ensure that no part of building is within 20' of front yard lot line.
|
Routing - Addressing | 6/27/2019 | | 6/27/2019 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 6/27/2019 | | 6/27/2019 | | PASS |
Morgan Webb
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 6/27/2019 | | DONE |
|
|
|
|
Intake Approval | | | 6/27/2019 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 6/27/2019 | | DONE |
|
|
|
|
Application received | | | 6/26/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Jun 26 2019 10:48AM
|