Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD19-02384
StatusFinaled
Name HARDING HOMES INC
Site Address 9681 W MACAW ST
Project NameEronel Sub
Customer Number 
ePlanReviewYes
Description
**PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 1621 sq. ft., two story (first story 1150 sq. ft., second story 471 sq. ft.) single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 276 sq. ft. of covered patio/porch, 248 sq. ft. of storage space, and a 475 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Routing - MECHANICAL2/18/2020 2/18/2020 PASS
DetailsTroy James
Resubmitted manual j report
BLD-Final1/14/20201/15/20201/15/2020PPASS
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by James Jackson//corrections made//final complete//
DOC - Permit Finaled1/15/20201/15/20201/15/2020PPASS
DetailsTell Riley
BLD-Final1/13/20201/14/20201/14/2020AFAIL
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by James Jackson//CN posted on electrical panel--need bollard for mechanical protection-need to seal gyp board behind furnace//
BLD-Blower Door Test Results1/14/20201/14/20201/14/2020ADONE
DetailsTell Riley
5.0 ACH 50
BLD-Energy code compliance10/15/201910/16/201910/16/2019APASS
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by James Jackson
BLD-Framing/Rough-in10/14/201910/15/201910/15/2019APASS
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by James Jackson//corrections made//
BLD-Framing/Rough-in10/11/201910/14/201910/14/2019APART
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by James Jackson//need truss plans and fire blocking at concealed space//ok to insulate only//
Routing - MECHANICAL10/9/2019 10/9/2019 PASS
DetailsChad Schwendiman
Revised manual J
Meeting  10/9/2019 DONE
Plan mod cancelled per Chad S., minor change only.
Plan Modification Accepted  10/8/2019 DONE
per James Jackson of Harding Homes - start plan mod - Manual J workflow
BLD-Wall Bracing9/20/20199/23/20199/23/2019APART
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by James Jackson//ok to wrap exterior//check blocking and portal frame straps at framing//will need to add holddown at front door where STHD14 is in wrong location//
BLD-Footing8/13/20198/13/20198/13/2019PPASS
DetailsTell Riley
Gilbert Phone #: ###-####//setbacks ok per plans//
Issue PAID IN FULL permit  8/1/2019 DONE
Inspection Record Card- Bld  8/1/2019 DONE
OVERRIDE  7/29/2019  
Plan assigned to (J_N)6/27/20196/27/20197/29/2019 DONE
DetailsJenny Nelson
07/10 sfd L1 ePlan.3rd review, failed planning again. 2nd reveiw, wall bracing still inadequate. 1st complete 7/8, inadequate wall bracing
Routing - PLANNING7/29/2019 7/29/2019 PASS
DetailsEthan Mansfield
PLANS/APPL TAKEN TO FRONT DESK  7/29/2019 DONE
DetailsJenny Nelson
Permit Ready to Issue  7/29/2019 DONE
Routing - PLANNING7/25/2019 7/26/2019 FAIL
DetailsEthan Mansfield
All structures must be located outside of 20 feet from the front property line per notes 7 and 10 of Eronel Sub Plat.
Routing - PLAN CHECK7/25/2019 7/25/2019 PASS
DetailsJenny Nelson
Routing - PLANNING7/22/2019 7/22/2019 FAIL
DetailsEthan Mansfield
All structures must be build outside the two stacked 10' easements (20' total) from front property line. There is a 10' ACHD storm drain easement and a 10' public utilities easement that are stacked for a total of 20' from the front property line.
Routing - PLAN CHECK7/22/2019 7/22/2019 FAIL
DetailsJenny Nelson
1st review completed  7/8/2019 DONE
DetailsJenny Nelson
Routing - PLAN CHECK6/27/2019 7/8/2019 FAIL
DetailsJenny Nelson
inadequate wall bracing
Routing - MECHANICAL7/2/2019 7/2/2019 PASS
DetailsChad Schwendiman
Route to Impact Fee Review6/27/20196/30/20196/28/2019 PASS
DetailsEric Bilimoria
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL6/27/2019 6/28/2019 FAIL
DetailsChad Schwendiman
The R value of the ceilings doesn't match the submitted plans
Routing - PLANNING6/27/2019 6/28/2019 FAIL
DetailsEthan Mansfield
There are 2 10' stacked easements along the front property line (See Plat notes 7 and 10). Please ensure that no part of building is within 20' of front yard lot line.
Routing - Addressing6/27/2019 6/27/2019 PASS
DetailsLaura Hunter
Routing - PUBLIC WORKS6/27/2019 6/27/2019 PASS
DetailsMorgan Webb
Plans ACCEPTED BY PLAN TECH  6/27/2019 DONE
Intake Approval  6/27/2019 PASS
Recd Pcfee & Taken To Pln CK  6/27/2019 DONE
Application received  6/26/2019 DONE
Application submitted via PDS Online on Jun 26 2019 10:48AM