Letter of compliance/Occupancy | | | 12/27/2019 | | DONE |
|
|
|
|
BLD-Final | 12/26/2019 | 12/26/2019 | 12/26/2019 | P | PASS |
Dave Hannah
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
DOC - Permit Finaled | 12/26/2019 | 12/26/2019 | 12/26/2019 | P | PASS |
Dave Hannah
|
|
|
|
BLD-Blower Door Test Results | 12/26/2019 | 12/26/2019 | 12/26/2019 | P | PASS |
Dave Hannah
|
|
|
4.2
|
BLD-Final | 12/17/2019 | 12/17/2019 | 12/17/2019 | P | NR |
Mike Jordan
|
|
|
garage door code is 2468, fire door will be open. Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Energy code compliance | 10/31/2019 | 10/31/2019 | 10/31/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 10/31/2019 | 10/31/2019 | 10/31/2019 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Framing/Rough-in | 10/29/2019 | 10/30/2019 | 10/30/2019 | A | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Provide strong back on gable end in garage. Strap double top plate break in garage. Provide more nails in king studs to headers.(ALL). Provide purlins on top chords of B2, B3 and B4 trusses at over build. Ok to insulate. Correction notice posted.
|
Fees Due Hold | 10/29/2019 | | 10/29/2019 | | DONE |
|
|
|
|
BLD-Framing/Rough-in | 10/24/2019 | 10/25/2019 | 10/25/2019 | A | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Still need mech rough in inspection prior to framing inspection.
|
Routing - MECHANICAL | 10/24/2019 | | 10/25/2019 | | PASS |
Troy James
|
|
|
Resubmitted manual j report
|
Plan Modification Accepted | | | 10/24/2019 | | DONE |
|
|
|
plan mod request by Gloria Martinez per email for Manual J
|
BLD-Wall Bracing | 10/15/2019 | 10/16/2019 | 10/16/2019 | P | PASS |
Jim Storey
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Wall Bracing | 10/14/2019 | 10/15/2019 | 10/15/2019 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD-Foundation | 9/30/2019 | 10/1/2019 | 10/1/2019 | P | PASS |
Mike Jordan
|
|
|
dANE- FOUNDATION WALL Phone #: ###-####
|
BLD-Footing | 9/27/2019 | 9/30/2019 | 9/30/2019 | P | PASS |
Mike Jordan
|
|
|
Jerry Phone #: ###-####
|
Issue PAID IN FULL permit | | | 8/12/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/12/2019 | | DONE |
|
|
|
|
OVERRIDE | | | 7/11/2019 | | |
|
|
|
|
Plan assigned to (RDP) | 6/28/2019 | 6/28/2019 | 7/11/2019 | | DONE |
Rob Patrick
|
|
|
07/11 sfd L1 ePlan
|
Routing - PLAN CHECK | 6/28/2019 | | 7/11/2019 | | PASS |
Rob Patrick
|
|
|
|
1st review completed | | | 7/11/2019 | | DONE |
Rob Patrick
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/11/2019 | | DONE |
Rob Patrick
|
|
|
|
Permit Ready to Issue | | | 7/11/2019 | | DONE |
|
|
|
|
Routing - MECHANICAL | 6/28/2019 | | 7/2/2019 | | PASS |
Chad Schwendiman
|
|
|
Approved with mark-ups
|
Route to Impact Fee Review | 6/28/2019 | 7/1/2019 | 7/1/2019 | | PASS |
Eric Bilimoria
|
|
|
Initial residential review of new SFD permits requested for now.
|
Routing - PLANNING | 6/28/2019 | | 6/28/2019 | | PASS |
Sue Cummings
|
|
|
|
Routing - Addressing | 6/28/2019 | | 6/28/2019 | | PASS |
Laura Hunter
|
|
|
|
Routing - PUBLIC WORKS | 6/28/2019 | | 6/28/2019 | | PASS |
Morgan Webb
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 6/28/2019 | | DONE |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 6/28/2019 | | DONE |
|
|
|
|
Intake Approval | | | 6/28/2019 | | PASS |
|
|
|
|
Application received | | | 6/27/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Jun 27 2019 3:35PM
|