Letter of compliance/Occupancy | | | 2/4/2020 | | DONE |
|
|
|
|
BLD-Final | 1/27/2020 | 1/28/2020 | 1/28/2020 | A | PASS |
Mike Jordan
|
|
|
Dean Phone #: ###-####- PLEASE CALL FOR ACCESS
|
DOC - Permit Finaled | 1/28/2020 | 1/28/2020 | 1/28/2020 | P | PASS |
Mike Jordan
|
|
|
|
FIRE-Final Inspection | 1/22/2020 | 1/22/2020 | 1/22/2020 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed.
Dean Phone #: ###-####
|
BLD-Energy code compliance | 10/29/2019 | 10/30/2019 | 10/30/2019 | A | PASS |
Mike Jordan
|
|
|
Dean Phone #: ###-####
|
BLD-Framing/Rough-in | 10/28/2019 | 10/28/2019 | 10/28/2019 | P | PASS |
Mike Jordan
|
|
|
Dean Phone #: ###-####
|
BLD-Framing/Rough-in | 10/24/2019 | 10/25/2019 | 10/25/2019 | A | FAIL |
Mike Jordan
|
|
|
Call for access // Dean Phone #: ###-####. Complete lateral bracing onJ1 A4, A7, B1, B2 and B3 trusses in unit #201. Remove foam from penetrations in floor of unit 201 and fire caulk. Fire block all concealed areas in units 210 and 101. Remove foam from top plates and around plumbing penetrations and fire caulk in unit 101. Provide raditation dampers for vent fans in units 101. Complete sheet rock at lid above fireplace in unit 101. provide 2 layers of 5/8 type x rock around tub drains. Correction notice posted.
|
BLD-Wall Bracing | 9/4/2019 | 9/5/2019 | 9/5/2019 | A | PASS |
Mike Jordan
|
|
|
Dean Phone #: ###-####. Ok to side.
|
BLD-Conference | 8/14/2019 | 8/15/2019 | 8/15/2019 | A | DONE |
Mike Jordan
|
|
|
Dean Phone #: ###-####
|
BLD-Conference | 7/23/2019 | 7/24/2019 | 7/24/2019 | A | DONE |
Tell Riley
|
|
|
Call 30 minutes ahead // Dean Phone #: ###-####
|
Routing - MECHANICAL | 7/16/2019 | | 7/16/2019 | | PASS |
Chad Schwendiman
|
|
|
|
Issue PAID IN FULL permit | | | 7/16/2019 | | DONE |
|
|
|
|
Route to Impact Fee Review | 7/12/2019 | 7/15/2019 | 7/15/2019 | | PASS |
Eric Bilimoria
|
|
|
Review requested for Commercial Permit
|
Inspection Record Card- Bld | | | 7/15/2019 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 7/15/2019 | | DONE |
|
|
|
met
|
Telephone call | | | 7/15/2019 | | DONE |
|
|
|
Called Dean to informed him of the fees and ready for pick up
|
Plan assigned to (JG) | 7/8/2019 | 7/8/2019 | 7/12/2019 | | PASS |
Javier Guzman
|
|
|
07/12 Fire Repair paper
|
Case Summary (BLD) | | | 7/12/2019 | | DONE |
Javier Guzman
|
|
|
|
Routing - PLAN CHECK | 7/12/2019 | | 7/12/2019 | | PASS |
Javier Guzman
|
|
|
|
1st review completed | | | 7/12/2019 | | DONE |
Javier Guzman
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/12/2019 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 7/8/2019 | | DONE |
|
|
|
|
Intake Approval | | | 7/8/2019 | | PASS |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/8/2019 | | DONE |
|
|
|
|
First Notice | 1/28/2020 | 1/28/2020 | | | |
Mike Jordan
|
|
|
|
Application received | | 7/1/2019 | | | |
|
|
|
|