Permit Information
Permit NumberBLD19-02595
StatusFinaled
Name MARK H BOWEN
Site Address 1000 W MYRTLE ST
Project NameJUMP - Smoke door, etc.
Customer Number 
ePlanReviewYes
Description
(JUMP – ROLL DOWN SMOKE DOOR AND CROSS CORRIDOR DOOR) (CZC19-00200) The fire sprinkler system is used for high rise, fire flow, and for fire area. This building is a community assembly and community education building. To install an automatic-closing roll-down non-egress smoke door on the 1st story in an existing interior non-bearing smoke partition wall located between the basement garage stairway and an exterior stairway serving upper stories. The door is required to close by smoke detectors, by the fire alarm system, and/or by power loss. The opening is required to be located away from the existing standpipe so that there is no hazard to the passing public. To install a double-leaf opposite swinging egress door on the 6th story between the exterior balcony and a covered hallway. The direction of egress is primarily between the exterior balcony and the covered hallway. Each door leaf will have a closer but neither door leaf will have a lock or a latch. Special Inspection is required for anchors post-installed in hardened concrete. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
CHANGE STATUS TO (FNL)  1/15/2020 DONE
Electrical permit pulled and finaled out. Ok to final permit.
Letter of compliance/Occupancy  1/15/2020 DONE
BLD-Final1/2/20201/2/20201/2/2020PPASS
DetailsDave Hannah
The project is ready for inspection if you want to fit it in before noon. I have scheduled the fire final as well if you can coordinate with Jim to follow him. Just call. Phone #: ###-#### Inspection requested via web by Mark Bowen // see meeting activty
DOC - Permit Finaled1/2/20201/2/20201/2/2020PPASS
DetailsDave Hannah
FIRE-Final Inspection1/2/20201/2/20201/2/2020PPASS
DetailsJim Page
Fire alarm inspection complete, no fire sprinkler modifications, fire extinguishers are in common areas with current inspection tags. Final life fire safety inspection for sope of work is complete, signatures provided on permit sign off card.

The project is ready for inspection if you want to fit it in before noon. Just call Phone #: ###-#### Inspection requested via web by Mark Bowen
CHANGE STATUS TO (ISS)  1/2/2020 DONE
Per Carl M and Daryl D, Electrical permit and inspection is required before permit can be finaled.
Meeting  1/2/2020 DONE
Per Carl M and Daryl D, Electrical permit and inspection is required before permit can be finaled.
BLD-Conference10/25/201910/25/201910/25/2019PDONE
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Mark Bowen
Issue PAID IN FULL permit  8/12/2019 DONE
Inspection Record Card- Bld  8/12/2019 DONE
Plan assigned to (CJW)7/31/20198/12/20198/8/2019 PASS
DetailsCarl Westfall
08/07/19 (L-2 - 10 days) (eplan - 3 sheets) Jump
Routing - PLAN CHECK7/31/2019 8/8/2019 PASS
DetailsCarl Westfall
Plan review approved
1st review completed  8/8/2019 DONE
PLANS/APPL TAKEN TO FRONT DESK  8/8/2019 DONE
Permit Ready to Issue  8/8/2019 DONE
MET
NEED-
GC
Revised Certificate of value
Routing - Design Review7/31/2019 7/31/2019 PASS
DetailsKatelyn Menuge
Intake Approval  7/30/2019 PASS
DetailsJavier Guzman
Intake Approval  7/16/2019 FAIL
DetailsBrian McGowan
Please provide the following for your Prescreen to be approved:
1. Form #304 must be completely filled out.
2. Provide Planning and Zoning Approval letters for exterior modifications.
Intake Approval  7/16/2019 FAIL
DetailsBrian McGowan
JUMP is in a Design Review Overlay. Planning and Zoning approval letters will be needed.
Application received  7/12/2019 DONE
Application submitted via PDS Online on Jul 12 2019 3:04PM